A61M   1/00  \	0	0	4C077	A61M   1/00	682	Ѥε۰ޤϥݥ֡αդޤƳ֡ӱեƥʥơƥͣѤäŬ礵³񡤴ɷѼꡤۤޤʬͣջμ褹뤿Ѷ£Ѥñսãɤؤο߼ե륿ƣˡΣ	Suction or pumping devices for medical purposes; Devices for carrying-off, for treatment of, or for carrying-over, body-liquids; Drainage systems (catheters A61M 25/00; devices for taking samples of blood A61B 5/14; implements for holding wounds open A61B 17/02; saliva removers for dentists A61C 17/04; pumps in general F04)
A61M   1/00 100 \	1	1	4C077	A61M   1/00	399	۰ɥʡѤƴ㡥żƴ	Containers for suction drainage, e.g. rigid containers
A61M   1/00 101 \	2	2	4C077	A61M   1/00	36	ƴ⤬ͽᱢˤƤ	inside the container maintained in neative pressure in advance
A61M   1/00 103 \	2	2	4C077	A61M   1/00	75	۰ƴˤʤͭ	having means to empty the suction coontainer
A61M   1/00 105 \	2	2	4C077	A61M   1/00	90	۰ϤϽФưɤ¢ƤΡ㡥ʹʵ۰ϤϽФͭΣͣ饹۳ѣͣ	contains built-in movable wall for enerating suction power, e.g. syringe (having elastic member fo generating suction power A61M1/00 107; glass cup A61M1/08)
A61M   1/00 107 \	2	2	4C077	A61M   1/00	88	۰ϤϽФ¢ɥʡƴ	drainage container containing built-in elastic members for generating suction power
A61M   1/00 109 \	2	2	4C077	A61M   1/00	113	ƴ	water seal container
A61M   1/00 111 \	2	2	4C077	A61M   1/00	77	żƴΥХåޤϥ饤ʤǤäơżƴޤϥХå㤷ϥ饤ʤФ۰ȼ	bag or liner in rigid container involvig suction against rigid container or bag or liner
A61M   1/00 120 \	1	1	4C077	A61M   1/00	198	ˤʤ褦Ŭ礵Ƥʤɥʡƴ㡥ޡǢ뤿˴ԤȤˤĤ֣ƣ	drainage container not adapted for becomg vacuum, e.g. bag (apparatus worn by patient to receive urine A61F5/44)
A61M   1/00 130 \	1	1	4C077	A61M   1/00	594	۰ɥʡƥʤΤƴͣ۰ƥͣ	suction drainage system (container therefor A61M1/00 100;  suction irrigation system A61M1/00 140)
A61M   1/00 131 \	2	2	4C077	A61M   1/00	374	۰	suction control
A61M   1/00 133 \	3	3	4C077	A61M   1/00	77	̵ΥѤ뤳Ȥˤ	by changing size of the vent
A61M   1/00 135 \	3	3	4C077	A61M   1/00	280	饤ʬ㡥ήĴۡѤ뤳Ȥˤ	by changing part of the line, e.g. flow adjusting valve
A61M   1/00 137 \	3	3	4C077	A61M   1/00	63	ַޤ̮ư۰ʣͣͥ	intermittent or pulsation type suction (A61M1/00 103 takes precedence)
A61M   1/00 140 \	1	1	4C077	A61M   1/00	353	۰ƥ	aspiration/irrigation system
A61M   1/00 150 \	1	1	4C077	A61M   1/00	314	۰ݥסʣͣͣͣͣͥ	suction pump (A61M1/00 101, A61M1/00 107, A61M1/00 130, A61M1/10 take precedence)
A61M   1/00 151 \	2	2	4C077	A61M   1/00	65	ԥȥݥ	piston pump
A61M   1/00 160 \	1	1	4C077	A61M   1/00	968	ɥʡ塼	drainage tube
A61M   1/00 161 \	2	2	4C077	A61M   1/00	652	۰ü㡥Υ롤	aspiration tip, e.g. nozzle, needle
A61M   1/00 170 \	1	1	4C077	A61M   1/00	199	ӽФ줿Τʤͭ	having means to treat discharged liquid
A61M   1/00 171 \	2	2	4C077	A61M   1/00	44	ӱդ˹ݺޤޤϥ벽ޤФʤͭɥ졼	drain device havig means to release antimicrobial or gelling agent on waste liquid
A61M   1/00 180 \	1	1	4C077	A61M   1/00	146	ؤεŪʽ㡥۰	Carrying off feces mechanically, e.g.,  suction
A61M   1/00 190 \	1	1	4C077	A61M   1/00	149	ʢ϶֡㡥ʢɲǻ̺ѥƥ	device for treating  ascitics or pleural effusion, e.g. system for filtration enricment and intravenous re-injection of ascitics
A61M   1/02  \	1	1	4C077	A61M   1/02	354	֡͢ˤդͣ	Blood transfusion apparatus (blood infusion by syringes A61M 5/14)
A61M   1/02 100 \	2	2	4C077	A61M   1/02	508	ե륿Ρ㡥ե륿	with filters, e.g. leucocyte removing filter
A61M   1/02 101 \	3	3	4C077	A61M   1/02	38	Хѥʤͭ	with means to bypass
A61M   1/02 103 \	3	3	4C077	A61M   1/02	148	ʬΥƤƴħΤ	characterized by conainer conaining separation member
A61M   1/02 105 \	4	4	4C077	A61M   1/02	104	ƴʬΥबƤ줿	separation member being accomodated in elastic container
A61M   1/02 107 \	3	3	4C077	A61M   1/02	441	ʬΥħΤ	characterized by sepaation member
A61M   1/02 110 \	2	2	4C077	A61M   1/02	28	ʬΥʤͭΡ㡥ͭޤϥޤ𤹤и	with gas separating means, e.g. spout euipped with memrane of gas bag with very small holes
A61M   1/02 120 \	2	2	4C077	A61M   1/02	353	ʬΥ	centrifugal separation
A61M   1/02 121 \	3	3	4C077	A61M   1/02	376	ƴѤ	using elastic container
A61M   1/02 123 \	3	3	4C077	A61M   1/02	184	̤򸡽Ф	detecting interface
A61M   1/02 125 \	3	3	4C077	A61M   1/02	281	ʬΥδ֡ʪäޤϰȴʤѤΡ㡥Ϣ³ʬΥ	taking measures to add or pull out liquid substances during centrifugal separation, e.g. consecutive centrifugal separation
A61M   1/02 130 \	2	2	4C077	A61M   1/02	245	ˤʬΥΡե륿ϣͣ	separation by adsorption
A61M   1/02 140 \	2	2	4C077	A61M   1/02	134	¾ηʬΥʡ㡥ʬΥ	other blood separation mean, e.g. sedimentation
A61M   1/02 150 \	2	2	4C077	A61M   1/02	240	̤椹ʡ㡥ƴνŤ̤ãȤưŪߤ뤳Ȥˤ	meas to control blood volume, e.g. sutomatically stops blood transmission when weight of container reaches predetermined figure
A61M   1/02 160 \	2	2	4C077	A61M   1/02	81	ƴưʤͭ	having means to swing blood container
A61M   1/02 165 \	2	2	4C077	A61M   1/02	109	ץդμ褹ʤͭ	having meas to gather blood sample
A61M   1/02 170 \	2	2	4C077	A61M   1/02	143	ʬżȡ㡥ˤդ	cleaning blood constituent; treatmento of blood by electromagnetic wave, e.g. light, radiation
A61M   1/02 175 \	2	2	4C077	A61M   1/02	40	դޤϲह	freeze or defreeze blood
A61M   1/02 180 \	2	2	4C077	A61M   1/02	449	⥸塼벽줿Ρ㡥塼֤ۡ塼֤ȥݥ	modularization, e.g. tube and valve, tube and pump
A61M   1/04  \	1	1	4C077	A61M   1/04	69		Pneumothorax apparatus
A61M   1/06  \	1	1	4C077	A61M   1/06	440		Milking pumps
A61M   1/08  \	1	1	4C077	A61M   1/08	141	饹۳	Cupping glasses
A61M   1/14  \	1	1	4C077	A61M   1/14	503	Ʃϥƥࡨ͹ǡջǲ֡ʺħΤȾƩ졤Τ¤£ģˡΣ	Dialysis systems; Artificial kidneys; Blood oxygenators (semi-permeable membranes characterised by the material, manufacturing processes therefor B01D 71/00) [4]
A61M   1/14 100 \	2	2	4C077	A61M   1/14	208	Ԥ	Controlling centrally
A61M   1/14 110 \	2	2	4C077	A61M   1/14	464	ɽħΤ	Characterized by an operation unit, a display unit
A61M   1/16  \	2	2	4C077	A61M   1/16	215	ͭΡΣ	with membranes [4]
A61M   1/16 100 \	3	3	4C077	A61M   1/16	43	ηꤵƤʤ	membrane of unlimited shape
A61M   1/16 101 \	4	4	4C077	A61M   1/16	265	졤ե륿¤ˡ	composition, structure, manufacturing method  of membrane, filter
A61M   1/16 103 \	4	4	4C077	A61M   1/16	24	ӤħΤ	characterized by intended use
A61M   1/16 105 \	5	5	4C077	A61M   1/16	170	͹¡	for artificial kidney
A61M   1/16 107 \	5	5	4C077	A61M   1/16	249	͹	for artificial lung
A61M   1/16 109 \	5	5	4C077	A61M   1/16	29	ʬª	for capturing constituent
A61M   1/16 110 \	3	3	4C077	A61M   1/16	539	Ʃϥƥ	control of dialysis system
A61M   1/16 111 \	4	4	4C077	A61M   1/16	1021	ƻ롤	monitoring, alarming
A61M   1/16 113 \	5	5	4C077	A61M   1/16	66	Ʃϱؤηդκ򸡽Ф	detect contamination of blood into dialysis liquid
A61M   1/16 115 \	4	4	4C077	A61M   1/16	255	Ʃϰ¬ꡤ	measuring, controlling of dialysis pressure
A61M   1/16 117 \	4	4	4C077	A61M   1/16	520	Ʃ̤¬ꡤ	measuring, controlling of dialysis volume
A61M   1/16 120 \	3	3	4C077	A61M   1/16	180	ηǮ򴹴	built-in heat exchanger
A61M   1/16 130 \	3	3	4C077	A61M   1/16	59	ʣƩϥ˥åȤĤ	having multiple dialysis units
A61M   1/16 135 \	3	3	4C077	A61M   1/16	157	ӻѺѤߤƩϱդδ֤ΥХ󥹤ȤѼĤΡ㡥ʣݥפĤ	having volme chamber to balance unused and used dialysis liquid, e.g. having duplex pump
A61M   1/16 140 \	3	3	4C077	A61M   1/16	57	ӻѺѤߤƩϱդν̤¬	measuring weight of unused and used dialysis liquid
A61M   1/16 145 \	3	3	4C077	A61M   1/16	23	Ʃϱդή줬̮ư	dialysis liquid to make pulsatory motion
A61M   1/16 150 \	3	3	4C077	A61M   1/16	15	ƩϱղϩХѥ줿ƩϴĤ	having dialysis apparatus bypassed from of circuit of dialysis liquid
A61M   1/16 155 \	3	3	4C077	A61M   1/16	130	˥åȤΤλٻޤϥåƥ	support or lock system for membrane unit
A61M   1/16 160 \	3	3	4C077	A61M   1/16	192	Ʃϱ	dialysis liquid
A61M   1/16 161 \	4	4	4C077	A61M   1/16	441	ƩϱդĴ뤿	device to adjust dialysis liquid
A61M   1/16 163 \	5	5	4C077	A61M   1/16	289	Ʃϱդ¬ꡤ㡥ǻ١Ƴ١	measuring dialysis liquid, e.g. density, condition of motor, pH
A61M   1/16 165 \	5	5	4C077	A61M   1/16	112	ȴʤͭ	having gas releasing means
A61M   1/16 167 \	5	5	4C077	A61M   1/16	123	Ǯʤͭ	having heating means
A61M   1/16 169 \	6	6	4C077	A61M   1/16	14	ƩϱդȻѤ줿Ʃϱմ֤Ǯ򴹤ͭ	having means for heat exchange between new dialysis liquid and used dialysis liquid
A61M   1/16 171 \	6	6	4C077	A61M   1/16	84	֤ͭ	having temperature controling means
A61M   1/16 173 \	5	5	4C077	A61M   1/16	300	ΤϤȤˤ	by melting solid body
A61M   1/16 175 \	5	5	4C077	A61M   1/16	131	ƴκ	details of container
A61M   1/16 177 \	6	6	4C077	A61M   1/16	48	ǲǻʪΤβ	elastic packaging for solidified condensed substance
A61M   1/16 179 \	5	5	4C077	A61M   1/16	147	ե륿Ѥ	using membrane filter
A61M   1/16 181 \	5	5	4C077	A61M   1/16	47	Ʃϱդλݤ򤹤	sterilzing dialysis liquid
A61M   1/16 183 \	4	4	4C077	A61M   1/16	20	Ѥ㡥֥ߥ󡤤ޤ	containing protein, e.g. albumin
A61M   1/16 185 \	3	3	4C077	A61M   1/16	557	Ʃ֤Ƕ	cleaning, serilization f dialysis device
A61M   1/16 190 \	3	3	4C077	A61M   1/16	215	Ʃϱդκ򤹤ʤͭ	having means for reproduction of dialysis liquid
A61M   1/18  \	3	3	4C077	A61M   1/18	216	ݷΤΡΣ	in the shape of hollow fibres [4]
A61M   1/18 500 \	4	4	4C077	A61M   1/18	1543	¤ˡ	Composition, structure, manufacturing method of hollow thread materials
A61M   1/18 510 \	4	4	4C077	A61M   1/18	733	ι¤ħͭ	Characterized by structure of treatment devices
A61M   1/18 511 \	5	5	4C077	A61M   1/18	99	«η	Formation of thread bundles
A61M   1/18 513 \	5	5	4C077	A61M   1/18	146	«üθ	Fixing of thread bundle ends
A61M   1/18 515 \	5	5	4C077	A61M   1/18	140	«֡ؤνŶ	Placement of thread bundles, filling to columns
A61M   1/18 517 \	5	5	4C077	A61M   1/18	146	إåη¤	Shape, structure of header portion
A61M   1/18 520 \	4	4	4C077	A61M   1/18	265	Ӥħͭ	Characterized by purpose
A61M   1/18 523 \	5	5	4C077	A61M   1/18	467	͹¡	For artificial kidney
A61M   1/18 525 \	5	5	4C077	A61M   1/18	529	͹	For artificial lung
A61M   1/18 527 \	5	5	4C077	A61M   1/18	80	ʬª	For capturing ingredients
A61M   1/20  \	3	3	4C077	A61M   1/20	14	ɾΤΡΣ	tubular [4]
A61M   1/20 500 \	4	4	4C077	A61M   1/20	69	ɾ¤ˡ	Composition, structure, manufacturing method of tubular materials
A61M   1/20 510 \	4	4	4C077	A61M   1/20	72	Ӥħͭ	Characterized by purpose
A61M   1/22  \	3	3	4C077	A61M   1/22	8	ΤΡΣ	sheet-like [4]
A61M   1/22 500 \	4	4	4C077	A61M   1/22	264	Ⱦ¤ˡ	Composition, structure, manufacturing method of sheet materials
A61M   1/22 503 \	5	5	4C077	A61M   1/22	7	ʿ	Flat laminated body
A61M   1/22 505 \	6	6	4C077	A61M   1/22	28	Τη	Form of laminated body
A61M   1/22 510 \	4	4	4C077	A61M   1/22	454	ι¤ħͭ	Characterized by structure of treatment devices
A61M   1/22 513 \	5	5	4C077	A61M   1/22	13	Τθ	Fixing of laminated body
A61M   1/22 515 \	5	5	4C077	A61M   1/22	10	Ǽ	Storage cases
A61M   1/22 520 \	4	4	4C077	A61M   1/22	76	Ӥħͭ	Characterized by purpose
A61M   1/22 523 \	5	5	4C077	A61M   1/22	117	͹¡	For artificial kidney
A61M   1/22 525 \	5	5	4C077	A61M   1/22	60	͹	For artificial lung
A61M   1/22 527 \	5	5	4C077	A61M   1/22	31	ʬª	For capturing ingredients
A61M   1/24  \	4	4	4C077	A61M   1/24	138	˴ΡΣ	spirally wound [4]
A61M   1/26  \	3	3	4C077	A61M   1/26	2	ưΡΣ	which are moving [4]
A61M   1/26 500 \	4	4	4C077	A61M   1/26	12	ޤи̤ž	With membrane or surface facing the membrane that rotate
A61M   1/28  \	2	2	4C077	A61M   1/28	960	ʢƩϡΣ	Peritoneal dialysis [4]
A61M   1/28 100 \	3	3	4C077	A61M   1/28	417	Ʃϱ	dialysis liquid
A61M   1/28 105 \	4	4	4C077	A61M   1/28	97	Ʃϱդκ	reproduction of dialysis liquid
A61M   1/28 110 \	3	3	4C077	A61M   1/28	300	⥸塼벽줿Ρ㡥塼֤ۡ塼֤ȥݥ	modularization, e.g. tube and valve, tube and pump
A61M   1/28 120 \	3	3	4C077	A61M   1/28	328	塼֤ǡ³	cutting or connecting tube
A61M   1/28 130 \	3	3	4C077	A61M   1/28	345	ưʢƩϤħΤΡʽΤϣͣ	characterized by control of automatic peritoneal dialysis (control for centralized management A61M1/14 100)
A61M   1/30  \	2	2	4C077	A61M   1/30	126	ñƩϡΣ	Single needle dialysis [4]
A61M   1/32  \	2	2	4C077	A61M   1/32	29	Ѥʤǲ֡Σ	Oxygenators without membranes [4]
A61M   1/32 500 \	3	3	4C077	A61M   1/32	88	ˢ͹	Bubble-type artificial lungs
A61M   1/32 510 \	3	3	4C077	A61M   1/32	12	žķ͹	Rotating disc-type artificial lungs
A61M   1/32 520 \	3	3	4C077	A61M   1/32	0	꡼󷿿͹	Screen-type artificial lungs
A61M   1/34  \	1	1	4C077	A61M   1/34	352	̲ᤵ뤳ȤˤդʪɲᡤʤɲᡤƩɲΣ	Filtering material out of the blood by passing it through a membrane, i.e. hemofiltration, diafiltration [4]
A61M   1/34 100 \	2	2	4C077	A61M   1/34	309	ɲޤϷƩɲΤͭΥե륿Ѥ	using distinctive filter for blood filtration or blood dialysis filtration
A61M   1/34 110 \	2	2	4C077	A61M   1/34	64	դϱդä롤㡥ִϱաʶŸǤɤΤΣͣ	add solutiion to blood, e.g. replacing soltion (preventing solidification A61M1/36 153)
A61M   1/34 120 \	3	3	4C077	A61M   1/34	62	ִդηϩ	path of replacing liquid
A61M   1/34 121 \	4	4	4C077	A61M   1/34	87	̤äΡ㡥žְϺΣԣͣС	returning through membrane, e.g. reversal of Trans Membrane Pressure [TMP]
A61M   1/34 123 \	4	4	4C077	A61M   1/34	152	ե륿ξήִդʤ	injecting replacing liquid at upstream of filter, i.e. front dilution
A61M   1/34 125 \	4	4	4C077	A61M   1/34	290	ե륿βήִդʤ	injecting replacing liquid at downstream of filter, i.e. rear dilution
A61M   1/34 130 \	3	3	4C077	A61M   1/34	149	³ɲΨκѤȤƤִΨ	controllig replacement rate as function of ultrafiltration rate
A61M   1/34 135 \	4	4	4C077	A61M   1/34	78	ѤΥХ󥹤ȤѼѤ	using volume chamber maintaining volume balance
A61M   1/34 140 \	3	3	4C077	A61M   1/34	59	ִ	replacement liquid
A61M   1/34 141 \	4	4	4C077	A61M   1/34	16	Ʃϱ¸ߤʤŲͭ	having electrolyte non-existing in dialysis liquid
A61M   1/34 143 \	4	4	4C077	A61M   1/34	64	ΤĴϩ	adjusting circuit therefor
A61M   1/34 145 \	4	4	4C077	A61M   1/34	146	ƩϱդִդȤѤ	using dalysis liquid as replacement liquid
A61M   1/36  \	1	1	4C077	A61M   1/36	166	ν۴ķϤФХѥˤդΤ¾ν㡥Ĵᡤȼ͡Σ	Other treatment of blood in a by-pass of the natural circulatory system, e.g. temperature adaptation, irradiation [4]
A61M   1/36 100 \	2	2	4C077	A61M   1/36	850	γղϩ	extracorporeal  blood circuit
A61M   1/36 101 \	3	3	4C077	A61M   1/36	118	٥븡д٥	level detector, level control
A61M   1/36 103 \	3	3	4C077	A61M   1/36	171	ˢд	bubble detector
A61M   1/36 105 \	3	3	4C077	A61M   1/36	362	찵ĴᡤΤäŬѴ	blood pressure control, pressure transducer specially adapted therefor
A61M   1/36 107 \	3	3	4C077	A61M   1/36	286	ήĴᡤΤäŬήѴήʬ	blood flow control, flowmeter transducer or flowmeter integrator specially adapted therefor
A61M   1/36 109 \	3	3	4C077	A61M   1/36	27	αդŵŪԡ¬ꡤΤäŬѴ	measuring electrical impedance of body fluid, transducer specially adapted therefor
A61M   1/36 111 \	3	3	4C077	A61M   1/36	597	ȴ֡Хåե塤ɥåץ	degassing device, buffer tank, drip chamber
A61M   1/36 113 \	4	4	4C077	A61M   1/36	17	ݥפ®٤Ѥƥȴ	changes pump speed for degassing
A61M   1/36 115 \	4	4	4C077	A61M   1/36	9	ưѤƥȴ	using vibratiion for degassing
A61M   1/36 117 \	4	4	4C077	A61M   1/36	303	η̮¡ڳ	built-in blood storage tub for vein, heart surgical operation
A61M   1/36 119 \	3	3	4C077	A61M   1/36	651	ʬե륿	blood constituet filter
A61M   1/36 121 \	3	3	4C077	A61M   1/36	327	ץ饤ߥ󥰡ޤǶ	priming, cleaning or sterilizing before or after use
A61M   1/36 123 \	4	4	4C077	A61M   1/36	184	Ѹ˻ααդӽФΡ㡥Τ֤	discharge remaining body fluid after use, e.g. return to body
A61M   1/36 125 \	4	4	4C077	A61M   1/36	57	ץ饤ߥϱդƽ۴Ĥʤͭ	ahaving means to recycle priming solution
A61M   1/36 127 \	4	4	4C077	A61M   1/36	120	Ʃϱդץ饤ߥ󥰤ޤդȤѤ	using dalysis liquid as priming or cleaning solvent
A61M   1/36 129 \	4	4	4C077	A61M   1/36	99	𤹤Ρ㡥žְϺΣԣͣСϤˤ	using membrane as medium, e.g. by Trans Membrane Pressure [TMP]
A61M   1/36 131 \	4	4	4C077	A61M   1/36	52	Ρ㡥Ѥ	using gas, e.g. air
A61M   1/36 141 \	3	3	4C077	A61M   1/36	280	Ԥηս۴Ĥγղϩ֤Υ󥿡ե	inerface between patient's blood circulation and extracorporeal blood circuit
A61M   1/36 143 \	4	4	4C077	A61M   1/36	229	ư̮ȡեƥ	artery - vein shunt, fistula
A61M   1/36 145 \	4	4	4C077	A61M   1/36	210	³Ǥ줿Ȥ򸡽Ф	detecting connectiion cutoff
A61M   1/36 147 \	5	5	4C077	A61M   1/36	27	եƥޤϥȤƽ۴Ĥ줿դ̤ɽ	displaying volume of purified blood recycling fistula or shunt
A61M   1/36 149 \	4	4	4C077	A61M   1/36	302	γϩտ魯륫˥塼	cannula annexed to extracorporeal  circuit
A61M   1/36 151 \	3	3	4C077	A61M   1/36	22	ߤ뤿ϱդĴ	adjusting solution for causing cardiac arrest
A61M   1/36 153 \	3	3	4C077	A61M   1/36	301	ŸǤɤʡ㡥إѥ	means to prevent solidification, e.g. injecting heparin
A61M   1/36 155 \	4	4	4C077	A61M   1/36	96	ŷ쥳ƥ󥰡㡥إѥ󥳡ƥ	anticoagulation coating, e.g. heparin coating
A61M   1/36 157 \	4	4	4C077	A61M   1/36	23		non-activating
A61M   1/36 161 \	3	3	4C077	A61M   1/36	218	ˤΡ㡥γ夹	by adsorptiion, e.g. adsorb granular leukocyte
A61M   1/36 163 \	4	4	4C077	A61M   1/36	195	ƴħΤ	characterized by container
A61M   1/36 165 \	4	4	4C077	A61M   1/36	1336	ħΤ	characterized by adsorbent
A61M   1/36 171 \	3	3	4C077	A61M   1/36	77	ȼͤ	Irradiating with radioactive rays
A61M   1/36 173 \	4	4	4C077	A61M   1/36	69	ޤѤ	using photoactive agent
A61M   1/36 175 \	3	3	4C077	A61M   1/36	350	ٽ	temperature treatment
A61M   1/36 181 \	3	3	4C077	A61M   1/36	234	ۤʤ̩٤ʬʬΥѤΡ㡥ʬΥ	using separation of constituent having different density, e.g. centrifugal separatiion
A61M   1/36 185 \	3	3	4C077	A61M   1/36	510	¾νԤΡ㡥˦ˤǤˤ	executing other treatment, e.g. treatment by cell, treatment by enzme
A61M   1/36 190 \	2	2	4C077	A61M   1/36	10	¾κ˦ʬΥưפˤ뤿źä줿γҤоݤȤʤ˦礵Ƥκ˦ʪŪѤΡ㡥ȱֿ	combining particles added to facilitate subsequent separation from other cells and te target cells to change physical properties of the target cells
A61M   1/38  \	2	2	4C077	A61M   1/38	414	ԤηդʬФĤ򶡷Ԥ᤹ΡΣ	Removing constituents from donor blood and returning remainder to body [5]
A61M   3/00  \	0	0	4C066	A61M   3/00	147	㡥Ĳꥬȥʣͣͥ表ԥȥͣˡΣ	Syringes; Irrigators; Baths for subaquatic intestinal cleaning
A61M   3/02  \	1	1	4C066	A61M   3/02	22	ĲꥬȥΣ	Enemata; Irrigators
A61M   3/02 100 \	2	2	4C066	A61M   3/02	386	Ĳ	for enema
A61M   3/02 110 \	2	2	4C066	A61M   3/02	842		for carrying out lavage
A61M   3/02 120 \	2	2	4C066	A61M   3/02	155	ζʤħΡ㡥ð¢ƴ狼Τ	characterized by liquid supply means, e.g. supply from pressurization storage container
A61M   3/02 122 \	3	3	4C066	A61M   3/02	83	Ϥˤ궡뤵	liquid supply using gravity
A61M   3/02 124 \	3	3	4C066	A61M   3/02	328	ðոľܶ뤵Ρ㡥ʪѤΡʥӥǤȷ礷Σͣ	direct supply from pressurization liquid source, e.g. supply of pharmacy (combined with bidet A61M3/06)
A61M   3/02 126 \	3	3	4C066	A61M   3/02	172	ݥ͢	pump transported liquid
A61M   3/02 130 \	2	2	4C066	A61M   3/02	43	ꥬȥΤΥɡۥǼ	stand for irrigator, holder, storage means
A61M   3/02 140 \	2	2	4C066	A61M   3/02	11	̮ưåȡưΥ	pulsation jet; vibration nozzle
A61M   3/02 150 \	2	2	4C066	A61M   3/02	517	˥塼졨Υ롧ü³	cannula; nozzle; point; connecting means thereof
A61M   3/02 152 \	3	3	4C066	A61M   3/02	138	ѤӽѤȤξʤȤ⣲Ĥ¦ήϩѤ	using at least two inner flow path for lavage and excretion
A61M   3/04  \	2	2	4C066	A61M   3/04	207	ҵܤäŬ礵ΡΣ	specially adapted for the uterus
A61M   3/06  \	2	2	4C066	A61M   3/06	187	ӥǤȷ礷ΡΣ	combined with bidets
A61M   5/00  \	0	0	4C066	A61M   5/00	175	鲼̮⡤⤫顤ΤƳ֡Τ°֡㡥Ŷޤ뤿֡ɪݤʰѤäŬ礵ܹ񡤴ɷѼꡤۤޤʬͣŤޤŪΤäŬ礵ƴʣˡΣ	Devices for bringing media into the body in a subcutaneous, intravenous, or intramuscular way; Accessories thereto, e.g. filling, holding, or cleaning devices, arm-rests
A61M   5/00 500 \	1	1	4C066	A61M   5/00	375	ΤƳ뤿͢շϩߤʤ͢շϩߤͣ	auxiliary tools not established on liqid infusion path for delivering medium into human body (auxiliary tools established on liqid infusion path A61M5/14)
A61M   5/00 510 \	2	2	4C066	A61M   5/00	176	ʹ¸ݴ	storage and retention of syringe and materials
A61M   5/00 512 \	3	3	4C066	A61M   5/00	118	եࡦȺˤ¸	storageby film sheet materials
A61M   5/00 514 \	3	3	4C066	A61M   5/00	102	ƴˤ¸	storage by cylincrical container
A61M   5/00 516 \	3	3	4C066	A61M   5/00	236	ѷƴˤ¸	storage by rectangle container
A61M   5/00 518 \	3	3	4C066	A61M   5/00	221	ʹޤȤƱ¸	simultaneous storage of syringe and medicine
A61M   5/00 520 \	3	3	4C066	A61M   5/00	100	ʹ桦ʹêʰݸêХ̣£	syringe stand, syringe shelf (protection case, shelf, bag for medical use in general A61B19/02)
A61M   5/00 530 \	2	2	4C066	A61M   5/00	59	ӡʻ߷Τӣ£	tourniquet (tourniquet for hemostasis A61B17/12)
A61M   5/14  \	1	1	4C066	A61M   5/14	238	֡㡥ϤˤդΤΣ	Infusion devices, e.g. infusing by gravity; Blood infusion; Accessories therefor, e.g. for hanging-up (suction in pumping blood transfusion A61M 1/02)
A61M   5/14 500 \	2	2	4C066	A61M   5/14	713	͢ա͢쥻åȡʽ۴ļͣ͢Хӣʣꥬȥͣƥͣӿˣͣũͣͣͣ	transfusion, blood transfusion set (circulation style blood transfusion A61M1/02, 500; vial bottle A61J1/00, 310; irrigator A61M3/02; coinfusion system A61M5/14, 510; bottle needle A61M5/162, 500; drip tube A61M5/14, 520; filtering tool A61M5/165, 500; syringe injector A61M5/145)
A61M   5/14 510 \	2	2	4C066	A61M   5/14	466	ƥࡤ㡥ʬƥʻͣ˻ѥॳͥͣ	coinfusion system, e.g. dispensing system (three-way stopcock A61M39/22, 100; rubber connector for coinfusion needle A61M39/04)
A61M   5/14 520 \	2	2	4C066	A61M   5/14	329	ũʥե륿ͣΡ	drip tube (filter A61M5/165,500N)
A61M   5/14 522 \	3	3	4C066	A61M   5/14	26	˾	fall dumper
A61M   5/14 530 \	2	2	4C066	A61M   5/14	87	ߤ겼	suspending device
A61M   5/14 532 \	3	3	4C066	A61M   5/14	233	ٻ뤿Υɡ֥饱åȡޤΤΡʥꥬȥΤΤΣͣ	stans, bracket, and like to support injection auxiliaries (for irrigator A61M3/02)
A61M   5/14 540 \	2	2	4C066	A61M   5/14	352	ι֡㡥̤ե桼	device for injecting into body cavity, e.g. tube with needle running thrugh to endoscope barrel
A61M   5/14 580 \	2	2	4C066	A61M   5/14	104	ʣʪ򺮹	mixed injection of multiple substances
A61M   5/14 582 \	3	3	4C066	A61M   5/14	273	ΤΡ㡥ʬɡϢۡʥȣͣ塼֥ͥͣ	in parallel line, e.g. branch pipe, connection valve (access site A61M39/02; tube connector A61M39/10)
A61M   5/14 584 \	3	3	4C066	A61M   5/14	74	ľΤΡ㡥裲ʪݻƤƴ裱ʪ̲᤹	in serial line, e.g. first substance passing through container ontaining second substance
A61M   5/142  \	2	2	4C066	A61M   5/142	533	㡥ݥפѤΡΣ	Pressure infusion, e.g. using pumps
A61M   5/142 500 \	3	3	4C066	A61M   5/142	466	۰ưӽбưȼݥ	pump accompanied by suction movement and discharge movement
A61M   5/142 502 \	4	4	4C066	A61M   5/142	419	ľŪưưȼΡʤʤȤ⣳Ĥβðݥסʴɾβưͭݥףƣ£	with vermiculation movement in straight line, i.e. pump with at least three pressurization parts or spiral parts (pump having tubular flexible operating member F04B43/08)
A61M   5/142 504 \	4	4	4C066	A61M   5/142	294	顼ݥסʤưưΤΥ顼ͭݥףƣ£	roller pump (pump having roller for vermiculation movement F04B43/12)
A61M   5/142 506 \	4	4	4C066	A61M   5/142	24	塼ڥ顤󿴷ݥ	screw, impeller, centrifugal type pump
A61M   5/142 508 \	4	4	4C066	A61M   5/142	88	ưݥ	manually operated pump
A61M   5/142 520 \	3	3	4C066	A61M   5/142	537	Ѥ߷פ줿Ρ㡥ΤˤĤ	designed for portable use, e.g. to be carried by human body
A61M   5/142 522 \	4	4	4C066	A61M   5/142	843	ŽշΤ	pasted on skin
A61M   5/142 524 \	4	4	4C066	A61M   5/142	224	Ѥ̤˹ͰƤ줿	especially designed for imbedding
A61M   5/142 530 \	3	3	4C066	A61M   5/142	965	ץˤħŤ줿ץǽ楷ƥͭ	having injection control system that is programmable and characterized by injection program
A61M   5/145  \	3	3	4C066	A61M   5/145	149	ð줿¢ƴѤΡ㡥ԥȥʤˤΡΣ	using pressurised reservoirs, e.g. by means of pistons
A61M   5/145 500 \	4	4	4C066	A61M   5/145	1023	ԥȥʤˤð	pressurized by means of piston
A61M   5/145 502 \	5	5	4C066	A61M   5/145	216	ήΰˤưԥȥ	piston operated by hydrostatic pressure type
A61M   5/145 504 \	5	5	4C066	A61M   5/145	172	Хͺư	spring operated type
A61M   5/145 506 \	5	5	4C066	A61M   5/145	359	եȥǥ󥰼֡㡥	front loading type injection device, e.g. front insertion type injection device
A61M   5/145 508 \	5	5	4C066	A61M   5/145	503	¢ƴؤȿʽФԥȥͭ򴹲ǽ¢ƴ	having exchangeable storage container with piston rod which advance into storage container
A61M   5/145 510 \	5	5	4C066	A61M   5/145	317	ݥפΥԥȥ뤿θ򴹼¢ƴ	with exchangeable storage container to receive piston rod of pump
A61M   5/148  \	4	4	4C066	A61M   5/148	186	ΤΡʣͣͥˡΣ	flexible (A61M  5/155 takes precedence);;
A61M   5/148 500 \	5	5	4C066	A61M   5/148	154	ήΰˤ곰ðХåѤ	using flexible bag pressurized by outside hydrostatic pressure
A61M   5/152  \	5	5	4C066	A61M   5/152	226	¢ƴμ̤ˤðΡΣ	pressurised by contraction of elastic reservoirs
A61M   5/155  \	4	4	4C066	A61M   5/155	143	ˤðΡΣ	pressurised by gas
A61M   5/158  \	2	2	4C066	A61M   5/158	34	ˡΣ	Needles
A61M   5/158 500 \	3	3	4C066	A61M   5/158	86	ˡ㡥αֿˡʥơƥ뼰αֿˣͣʹѿˣͣɿˣ£ˡΤ㡥Ϳˤ뤿ΤΡޤϿΤͿˤݻ뤿ΤΡʿե륿ͣ	injection needle, e.g. indwelling needle (catheter type indwelling needle A61M25/06,500; needle for syringe A61M5/32; trocar A61B17/34); auxiliary tool thereof, e.g. for injecting syringe needle or for holding syringe needle on human body (filter inside needle A61M5/165, 500)
A61M   5/158 500 B	3	0	4C066	A61M   5/158	251	ˡ	manufacturing method
A61M   5/158 500 D	3	0	4C066	A61M   5/158	315		needle tip
A61M   5/158 500 F	3	0	4C066	A61M   5/158	387	˴	needle tube body
A61M   5/158 500 G	3	1	4C066	A61M   5/158	41	ʣήϩͭ˴	needle tube body having multiple flow channel
A61M   5/158 500 H	3	0	4C066	A61M   5/158	451	˴㡥˥ϥ	needle base, e.g. needle hub
A61M   5/158 500 K	3	0	4C066	A61M   5/158	117	ľѿ˷	right angled needle type device
A61M   5/158 500 N	3	0	4C066	A61M   5/158	69	ˤΤ˸ꤹ뤿δ	eqiupment to fix needle on human body
A61M   5/158 500 P	3	1	4C066	A61M   5/158	322		pterygium
A61M   5/158 500 R	3	1	4C066	A61M   5/158	89	Ⱦʪ	sheet-like materials
A61M   5/158 500 T	3	1	4C066	A61M   5/158	164	¾δ	other apparatus
A61M   5/158 500 Z	3	0	4C066	A61M   5/158	758	¾Τ	Others
A61M   5/162  \	2	2	4C066	A61M   5/162	69	˥åȡʤ¢ƴȴɤȤδ֤ɤˤϢΣ	Needle sets, i.e. connections by puncture between reservoir and tube
A61M   5/162 500 \	3	3	4C066	A61M   5/162	37	ӿˡʮк̩ͣüͭɤȤδɤͤɤˤΤϢͣ	bottle needle(jet effect injector A61M5/30; coupling tool for tube having sealed end and neddle to pierce it through A61M39/14)
A61M   5/162 500 B	3	0	4C066	A61M   5/162	29	ˡ	manufacturing method
A61M   5/162 500 D	3	0	4C066	A61M   5/162	40	ñήϩͭ	having single flow channel
A61M   5/162 500 F	3	1	4C066	A61M   5/162	51		needle tip
A61M   5/162 500 H	3	1	4C066	A61M   5/162	73	˴	needle tube body
A61M   5/162 500 J	3	1	4C066	A61M   5/162	41	˴	needle base
A61M   5/162 500 N	3	0	4C066	A61M   5/162	25	ʣήϩͭ	needle tube body having multiple flow channel
A61M   5/162 500 P	3	1	4C066	A61M   5/162	21		needle tip
A61M   5/162 500 R	3	1	4C066	A61M   5/162	46	˴	needle tube body
A61M   5/162 500 T	3	1	4C066	A61M   5/162	29	˴	needle base
A61M   5/162 500 V	3	1	4C066	A61M   5/162	63	뵤ϩ֤°ʤħΡ㡥ե륿ͭΡʶӽ뤿¿ե륿ͣ	characterized by accessory installed in air supply passage, e.g. having filter (hydrophobic filter to remove air A61M5/38, 500)
A61M   5/162 500 Z	3	0	4C066	A61M   5/162	98	¾Τ	Others
A61M   5/165  \	2	2	4C066	A61M   5/165	10	㡥եե륿ΤΤΥե륿ʣͣͣͥˡΣ	Filtering accessories, e.g. blood filters, filters for infusion liquids (A61M  1/34, A61M  5/36 take precedence);;
A61M   5/165 500 \	3	3	4C066	A61M   5/165	11	ʶ֣ͣ	filtering tool (air removal device A61M5/36)
A61M   5/165 500 B	3	0	4C066	A61M   5/165	139	Ω	independent filtering tool
A61M   5/165 500 J	3	0	4C066	A61M   5/165	26	°Τ	accessory filtering tool
A61M   5/165 500 N	3	1	4C066	A61M   5/165	75	ũ°Τ	accessory to drip tube
A61M   5/165 500 P	3	1	4C066	A61M   5/165	53	ˤ°Τ	accessory to cannula
A61M   5/165 500 R	3	1	4C066	A61M   5/165	121	¾δ°Τ	accessory to other tools
A61M   5/165 500 T	3	0	4C066	A61M   5/165	43	ե륿	filter element
A61M   5/165 500 V	3	1	4C066	A61M   5/165	109	㡥عʤ	structure, e.g. structure of layer
A61M   5/165 500 X	3	1	4C066	A61M   5/165	96		quality of material
A61M   5/165 500 Z	3	0	4C066	A61M   5/165	16	¾Τ	Others
A61M   5/168  \	2	2	4C066	A61M   5/168	148	ΤƳΤή椹ʤޤϿΤƳΤ̤ʡ㡥ũס׿סΣ	Means for controlling media flow to the body or for metering media to the body, e.g. drip meters, counters
A61M   5/168 500 \	3	3	4C066	A61M   5/168	1084	ή桨ήĴή̤ꤹ뤿	flow control; flow regulation; device to establish flow volume
A61M   5/168 502 \	4	4	4C066	A61M   5/168	265	ήϩγٹ礤椹뤳Ȥˤ	by controlling degree of opening of flow channel
A61M   5/168 504 \	4	4	4C066	A61M   5/168	252	ʣήΤã椹뤳ȤˤΡ㡥Ϣ³ޤ̤ήϩͳѤʤʣαΤͣ	by controlling delivery of multiple fluid body, e.g. through series of, mixed or separate flow channel (injection of multiple fluiud bodies without use of controller A61M5/14, 580)
A61M   5/168 506 \	4	4	4C066	A61M   5/168	493	Ĵۡۡ㡥ɤʤ뤿ʥףͣ	adjusting valve, on-off valve, e.g. clamp  to squeeze flexible tube (clamp A61M39/28)
A61M   5/168 510 \	3	3	4C066	A61M   5/168	520	ή̤ΰ۾ƻ롤СΡޤϽΡʼǤեۣͣ	monitor, detect, notify or remove abnormal injection flow (low level float valve causing shut off A61M5/40)
A61M   5/168 512 \	4	4	4C066	A61M   5/168	132	̤ȿ֤Τ뤳ȤˤΡ㡥򸡽Ф뤿ΤΡʿǤŪȤȿβ٤򸡽ФΣͣ	by use of sensor at injecting part to detect characteristics of organization or condition, e.g. to detect infiltration (detecting temperature of organization for treatment purpose A61M39/02, 110)
A61M   5/168 514 \	4	4	4C066	A61M   5/168	82	ǽʻ̤򸡽Ф뤳ȤˤΡ㡥λΤ	by detecting injectable residual quantity, e.g. notify completion of injection
A61M   5/168 514 C	4	0	4C066	A61M   5/168	221	ؼμ	optical means of detectoin
A61M   5/168 514 D	4	0	4C066	A61M   5/168	125	żμ	electromagnetic means of detection
A61M   5/168 514 E	4	0	4C066	A61M   5/168	95	̼μ	gravimetric means of detection
A61M   5/168 514 H	4	0	4C066	A61M   5/168	38	ͷΰ֤򸡽Ф뤳Ȥˤ	by detecting position of floating member
A61M   5/168 514 Z	4	0	4C066	A61M   5/168	128	¾μ	other means
A61M   5/168 516 \	4	4	4C066	A61M   5/168	297	饤󰵤δƻˤ	by monitoring line pressure
A61M   5/168 518 \	5	5	4C066	A61M   5/168	65	ϱɾħΡ㡥ĥѥ륹Ф	characyerized by evaluation of pressure response, e.g. against applied pulse
A61M   5/168 520 \	4	4	4C066	A61M   5/168	264	ĺɸ	detection of blockade
A61M   5/168 530 \	3	3	4C066	A61M   5/168	225	ή̤¬ꤹ뤿ΤΡ㡥ή̷	for measuring flow quantity, e.g. flowmeter
A61M   5/168 532 \	4	4	4C066	A61M   5/168	261	ũ	dripping meter
A61M   5/168 534 \	4	4	4C066	A61M   5/168	29	Ѳƻ뤹뤳ȤˤΡ㡥ƴΤ	by monitoring change of weight, e.g. of injection container
A61M   5/168 540 \	3	3	4C066	A61M   5/168	638	ɽʤħ	characterized by indication means
A61M   5/168 550 \	3	3	4C066	A61M   5/168	649	ٹʤħ	characterized by warning means
A61M   5/172  \	3	3	4C066	A61M   5/172	1069	ŵŪޤŻŪΣ	electrical or electronic
A61M   5/172 500 \	4	4	4C066	A61M   5/172	577	Υѥ᡼ΥեɥХåѤΡ㡥찵ʿΥѥ᡼¬£	using feedback of bodily parameter, e.g. blood sugar, blood pressure (measurement of bodily parameter A61B5/00)
A61M   5/175  \	3	3	4C066	A61M   5/175	88	ŪΣ	mechanical
A61M   5/178  \	1	1	4C066	A61M   5/178	401	ʹΣ	Syringes
A61M   5/178 500 \	2	2	4C066	A61M   5/178	311	ξʹνŶ֡ʰΤηʣ	device to support filling up of syringe on the spot (combination for transfusion, mixed injection A61J3/00, 314)
A61M   5/178 510 \	2	2	4C066	A61M   5/178	74	üʤޤ	including means to shelter radiatiion
A61M   5/19  \	2	2	4C066	A61M   5/19	293	ʾͭΡΣ	having more than one chamber
A61M   5/20  \	2	2	4C066	A61M   5/20	1375	ưʹ㡥ưŪ˶ưԥȥͭΡưŪΤΡưŪ˽ŶΡʣͣͥˡΣ	Automatic syringes, e.g. with automatically actuated piston rod, with automatic needle injection, filling automatically [2]
A61M   5/20 500 \	3	3	4C066	A61M   5/20	205	ԤοΤʹ郎ܿ뤳ȤˤäǽмʤȥꥬΡ֤ȩ˹ƲΤ߲ǽǤΣͣ	liquid discharge means is triggered by syringe making contact with patient body (device releasable only when it is pushed against skin A61M5/20, 572)
A61M   5/20 510 \	3	3	4C066	A61M   5/20	1008	Хͼåʹʿѣͣ	spring type shot syringe (exclusively used for inertion of needle A61M5/32, 530)
A61M   5/20 520 \	3	3	4C066	A61M   5/20	77	ʣŶѤγ¢ƴϢ뤵줿	linked with external storage container designd for repeated use
A61M   5/20 530 \	3	3	4C066	A61M   5/20	85	Τˤʹ狼ӽФ	medium discharged from syringe by generation of gas
A61M   5/20 540 \	3	3	4C066	A61M   5/20	76	ΤðήΤޤϿˤʹ狼ӽФΡΤͣͣ	medium discharged from syringe by pressurized fluid or vacuum (for injectionA61M5/145, A61M5/155)
A61M   5/20 550 \	3	3	4C066	A61M   5/20	528	ưͭ	having auto needle insertion function
A61M   5/20 560 \	3	3	4C066	A61M   5/20	197	İʾΤ뤿μʤǹΡ㡤ˤ	composed of means to inject more than one medium, e.g. by mixed injection
A61M   5/20 570 \	3	3	4C066	A61M   5/20	318	θεưɻߤΡ㡥åѤ뤳Ȥˤ	to prevent accidental start up, e.g. by using safety lock
A61M   5/20 572 \	4	4	4C066	A61M   5/20	220	֤ȩ˹ƲΤ߲ǽǤ	device released only when pushed against skin
A61M   5/24  \	2	2	4C066	A61M   5/24	1871	ץʹʤ򴹤Ǥ륢ץޤϥȥåȷ礷Ѥˤͭʹ㡥ưΣ	Ampoule syringes, i.e. syringes with needle for use in combination with replaceable ampoules or carpules, e.g. automatic (ampoules or carpules A61J 1/06)
A61M   5/24 500 \	3	3	4C066	A61M   5/24	503	ץۥ륢ץ롤㡥¦	insertion of ampoule into ampoule holder, e.g. insertion from side, from front
A61M   5/24 502 \	4	4	4C066	A61M   5/24	358		from back
A61M   5/24 510 \	3	3	4C066	A61M   5/24	95	ѷץޤϥȥåɤΰ̤ˤˤʤ	emptying ampoule or cartridge by compressing deformed ampoule or catridge wall
A61M   5/24 520 \	3	3	4C066	A61M   5/24	51	ʹΤΥƥ쥹ԥ󥰤ˤꥢץޤϥȥåˤʤ	emptying ampoule or cartridge by telescoping of syyringe body
A61M   5/24 530 \	3	3	4C066	A61M   5/24	315	İʾΤΤμʤǹΡ㡥ˤ	composed of means to inject more than one medium, e.g. by mixed injection
A61M   5/24 540 \	3	3	4C066	A61M   5/24	261	˲ޤϳ륷ʤͭΡ㡥	having sealing means to destroy or open, e.g. to open
A61M   5/24 542 \	4	4	4C066	A61M   5/24	82	ⰵ徺ˤΡ㡥̤ޤˤΡʣͣͥ	by increased internal pressure, e.g. by penetration or burst (A61M5/24, 520 takes precedence)
A61M   5/28  \	2	2	4C066	A61M   5/28	1858	ʹ異ץޤϥȥåʤˤͭ륢ץޤϥȥåΣ	Syringe ampoules or carpules, i.e. ampoules or carpules provided with a needle
A61M   5/28 500 \	3	3	4C066	A61M   5/28	182	ѷץޤϥȥåɤΰ̤ˤˤʤ	emptying ampoule or cartridge by compressing deformed ampoule or catridge wall
A61M   5/28 510 \	3	3	4C066	A61M   5/28	60	ݻФƥץޤϥȥå򥹥饤ɤ뤳ȤǶˤʤ	emptying ampoule or cartridge by aliding ampoule or catridge against needle retaining base
A61M   5/28 520 \	3	3	4C066	A61M   5/28	405	İʾΤΤμʤǹΡ㡥ˤ	composed of means to inject more than one medium, e.g. by mixed injection
A61M   5/28 530 \	3	3	4C066	A61M   5/28	317	˲ޤϳ륷ʤͭΡ㡥	having sealing means to destroy or open, e.g. to open
A61M   5/28 532 \	4	4	4C066	A61M   5/28	113	ⰵ徺ˤΡ㡥̤ޤˤΡʣͣͥ	by increased internal pressure, e.g. by penetration or burst (A61M5/28, 510 takes precedence)
A61M   5/30  \	2	2	4C066	A61M   5/30	680	ˤʤǡͽкѤˤäʹ㡥򴹤륢ץޤϥȥåѤΡΣ	Syringes for injection by jet action, without needle, e.g. for use with replaceable ampoules or carpules
A61M   5/30 500 \	3	3	4C066	A61M   5/30	141	ʹαṳ̈ʹ¤Υåήϩͭ	having jet flow passage having special structure at distal end of syringe
A61M   5/303  \	3	3	4C066	A61M   5/303	132	ˤ狼ΤӽФΡΣ	Media expelled from injector by explosive charge
A61M   5/307  \	3	3	4C066	A61M   5/307	161	ðήΤˤ狼ΤӽФΡΣ	Media expelled from injector by pressurised fluid
A61M   5/31  \	2	2	4C066	A61M   5/31	1343	Σ	Details [2]
A61M   5/31 500 \	3	3	4C066	A61M   5/31	160	ʹαüѤϳɻ߼	means to prevent leaking at distal end of syringe
A61M   5/31 502 \	4	4	4C066	A61M   5/31	257	ˤʤʹѥå	needleless syringe cap
A61M   5/31 510 \	3	3	4C066	A61M   5/31	100	ߤޤ̵ʤͭΡ㡥ԥȥξϩ	having means to air intake or ventilation, e.g. purification circuit inside piston
A61M   5/31 520 \	3	3	4C066	A61M   5/31	913	ɽʡ㡥̤ɽ뤿	specific display means, e.g. to display administration of dosage
A61M   5/31 530 \	3	3	4C066	A61M   5/31	868	ʹﳰʣͣӣͣͥ	outer cylinder of syringe (A61M5/32, 510 and A61M5/50 take precedence)
A61M   5/31 532 \	4	4	4C066	A61M   5/31	131	ⰵξ徺ˤαüؤѰ̸ˡޤ򱪲󤹤뤿ήϩαüͭ	having flow passage at distal end of syringe for infusion to detour around sealing plug after sealing plug is displaced to distal end by increased internal pressure
A61M   5/31 534 \	4	4	4C066	A61M   5/31	303	̤߷פ줿ե󥬡å׼ʡ㡥ԥȥưפ뤿Τ	means of specially designed finger grip, e.g. for easier handling of piston rod
A61M   5/31 540 \	3	3	4C066	A61M   5/31	129	ե륿Ȥ߹ޤ줿	filter being incorporated
A61M   5/315  \	3	3	4C066	A61M   5/315	1813	ԥȥ󡨥ԥȥ塨ԥȥư⡤˸ޤ¤Ρ뤿˥ԥȥդΣ	Pistons; Piston-rods; Guiding, blocking or restricting the movement of the rod; Appliances on the rod for facilitating dosing [2]
A61M   5/315 500 \	4	4	4C066	A61M   5/315	720	ԥȥư˸ޤ¤ʡʣͣͥ	means to interfere or limit movement of rod or piston (A61M5/50, 500 takes precedence)
A61M   5/315 502 \	5	5	4C066	A61M   5/315	240	ʹﳰ˰ΤΤΡʤĤʤޤϥ˥åȤ褦˳Ϣ뤵줿	integrated with syringe outer cylinder, i.e. connected to outer cylinder to form one part or unit
A61M   5/315 510 \	4	4	4C066	A61M   5/315	1063	ԥȥޤϥԥȥι¤㡥ԥȥȥԥȥȤϢʣͣͥ	structure of piston or piston rod, e.g. connection of piston and piston rod (A61M5/50, 520 takes precedence)
A61M   5/315 512 \	5	5	4C066	A61M   5/315	594	̩ޤϳ夵ԥȥ¤	piston structure to improve sealing or sliding
A61M   5/315 514 \	5	5	4C066	A61M   5/315	373	ԥȥȥԥȥϢ	connection of piston and piston rod
A61M   5/315 516 \	5	5	4C066	A61M   5/315	90	֤Ū礭򸺾뤿߷פ줿Ρ㡥ޤϥƥ쥹ԥå	designed to decrease overall size of injection device, e.g. provide rod member with flexibility or telescopic feature
A61M   5/315 550 \	4	4	4C066	A61M   5/315	72	ʬʤʬꤹ	mechanism to admisidter single dosage of medicine, i.e. determining single dosage
A61M   5/315 550 A	4	0	4C066	A61M   5/315	291	ޤϤ򰷤ʡ㡥˸ʡԽʬɻߤʡ¿ꤷ̤	means to improve safety or to handle it, e.g. means to interfere with, means to prevent insufficient dosage, means to correct established exces dosage
A61M   5/315 550 C	4	1	4C066	A61M   5/315	140	ȥåλ;̤Ķơ̤ꤹ뤳Ȥɤ	means to prevent establishment of dosage in excess of resedual in cartridge
A61M   5/315 550 E	4	1	4C066	A61M   5/315	119	ԥȥʡ㡥ȥå򴹤֡ԥȥ֤˰ᤵꡤٱ礹	means to initialize piston rod, e.g. means to restore piston rod to initial position or means to assist in doing so
A61M   5/315 550 G	4	0	4C066	A61M   5/315	82	Τξ֤ꡤ㡥̤	establishment of condition for medication, e.g. means tp administer dosage
A61M   5/315 550 J	4	1	4C066	A61M   5/315	159	ŵŪΤΡ㡥å꡼ץ饹ޥʥܥѤ	electrically operated medicine administrator, e.g. input using touch screen or plus/minus button
A61M   5/315 550 L	4	1	4C066	A61M   5/315	160	Ū	medicine administration member operated mechanically
A61M   5/315 550 N	4	2	4C066	A61M   5/315	235	βžưˤΡ㡥ޤʹνŶ	by rotation of dosage administration member, e.g. during administration or filling of syringe
A61M   5/315 550 P	4	3	4C066	A61M   5/315	564	μαưޤ	including movement in direction of axis of  dosage administration member
A61M   5/315 550 R	4	3	4C066	A61M   5/315	231	μαưޤޤʤ	not including movement in direction of axis of  dosage administration member
A61M   5/315 550 T	4	0	4C066	A61M   5/315	2	ͼ	pattern of administration if medicine
A61M   5/315 550 V	4	1	4C066	A61M   5/315	114	ñͿʤƱ¢ƴ狼롤ġꤵ줿Ϳ㡥칩¼ʤޤ	single medication, i.e. individually administered medication where only one medication is prescribed from a given medicine storage container, e.g. include means to limit one manufacturing process
A61M   5/315 550 X	4	1	4C066	A61M   5/315	413	ʣͿ㡥Ʊ¢ƴ狼鷫֤롤ġꤵ줿Ϳ	multiple medication, i.e. individually administered medication where more than one medication is prescribed from a given medicine storage container
A61M   5/315 550 Z	4	0	4C066	A61M   5/315	70	¾Τ	others
A61M   5/315 580 \	4	4	4C066	A61M   5/315	276	İʾΤΤμʤǹΡ㡥ˤ	composed of means to inject more than one medium, e.g. by mixed injection
A61M   5/32  \	3	3	4C066	A61M   5/32	3947	ˡʹޤϥϥ֤Ȥ³˴ؤˤκˣͣˡ˿ˤ롤ޤϿξ˿ˤٻ뤿°֡ˤݸ֡Σ	Needles; Details of needles pertaining to their connection with syringe or hub (infusion needles A61M 5/14); Accessories for bringing the needle into, or holding the needle on, the body; Devices for protection of needles [2]
A61M   5/32 500 \	4	4	4C066	A61M   5/32	1423	οˤݸΤ֡㡥åסʣͣͥ	device to protect unused needle, e.g. cap (A61M5/50 takes precedence)
A61M   5/32 502 \	5	5	4C066	A61M   5/32	266	˥å׽֡ʤϿ˥ϥ֤ݸС֡㡥æ	needle cap removing device, i.e. device to remove protection cover from needle or needle hub, e.g. shielding removig device
A61M   5/32 510 \	4	4	4C066	A61M   5/32	180	ѺѤ߿˼㤷ʹμ곰ѴΤ֡㡥ƴѺѤ߿ˤˤȯŪ»ɤμʡʴְ̣£á	device for removing or disposing used needle or syringe, e.g. container; means to prevent accidental injury by used needle (pulverizer in general B02C)
A61M   5/32 510 B	4	0	4C066	A61M   5/32	226	ѺѤߤοˤˤŪʽݸ뤿μ	means of protection from having acidental injury by used needle
A61M   5/32 510 D	4	1	4C066	A61M   5/32	488	ˤФƼ˥åפդΡ㡥ؤݸ֤Ρʼ˿ĥݸͣˡ	cap is mounted against needle in direction of axis, e.g. equipped with finger protection device (protective sheath extending along axis A61M5/32, 510K)
A61M   5/32 510 F	4	1	4C066	A61M   5/32	249	˾˲Ū֤륭åס㡥˴ǽ˼դ	cap is arranged transversely on top of needle, e.g. mounted so that it turns against needle base
A61M   5/32 510 H	4	1	4C066	A61M   5/32	604	߼ˡʤԥȥˤʹﳰ³졤˰Ρʥơƥȹ礻ɥˡɥݸ뤿δͣ	retractable needle, i.e. disconnected from outer cylinder of syringe by piston and retracted in it (tool to protect guide needle combined with catheter A61M25/06, 510)
A61M   5/32 510 K	4	1	4C066	A61M   5/32	713	˳ĥǽʼʡ㡥ʹﳰƱǳưǽݸ꡼֡ʥơƥȹ礻ɥˡɥݸ뤿δͣ	means extendable in direction of axis, e.g. protection sleeve that can slide on outer cylinder of syringe along its axis (tool to protect guide needle combined with catheter A61M25/06, 510)
A61M   5/32 510 M	4	2	4C066	A61M   5/32	40	ʹﳰƱŪ󤵤Ƥʤʤˤ⤵Ρ㡥ˡɥȷ礵줿⤷Υˡɥ˼ä뤿ʹﳰγɽ̾˷줿ͥ	guided by means not arranged in accordance with axis of outer cylinder of syringer, e.g. channel like member, formed on outside surface of outer cylinder of syringe, which guide pushing rod combined with needle sefety sheath, and replace needle safety sheath
A61M   5/32 510 P	4	2	4C066	A61M   5/32	250	ݸ꡼֤Ϫʤޤǥȥ뤵줿ưԤΰȥåͭ	having guiding track for needle protection sleeve for controlled slide from exposed part to covered part of needle
A61M   5/32 510 R	4	3	4C066	A61M   5/32	127	ӥ󥹾ϩ򤿤ɤ͵ͭΡ㡥͵ͻȿݸȤΰ֤Ȥ뤿ι¤ʤϵƻ	having projection following labyrinth like passage, e.g. means to prepare ditch or track so to enable projection to take different position before use, during injection and after use and needle is proteced
A61M   5/32 510 T	4	2	4C066	A61M   5/32	93	ʹˤ˷礹뤳Ȥʤ˴ɾͳ˳ư	sliding freely on needle tube without connection to syringe or needle
A61M   5/32 510 V	4	2	4C066	A61M   5/32	93	Ⱦˤˤäƿ˥ϥ֤ʹ˷礵Ρ㡥ĹġҤ	combined with needle hub or syringe by member swerving in direction of diameter, e.g. thin plate , rope or belt in longtitudinal direction
A61M   5/32 510 Z	4	0	4C066	A61M   5/32	541	¾Τ	others
A61M   5/32 520 \	4	4	4C066	A61M   5/32	342	üι¤ħΡ㡥̤夵뤿Τ	characterized by structure of tip of needle, e.g. to improve penetration
A61M   5/32 530 \	4	4	4C066	A61M   5/32	303	ˤƳ뤿°ʡưʣͣͥ	accessory for introducing needle into human body; automatic needle insertion (A61M5/20, 550 takes precedence)
A61M   5/32 540 \	4	4	4C066	A61M   5/32	399	˴ɤι¤ħΡ㡥ɲä¦̳	characterized by structure of needle tube, e.g. tube having additional opening on side
A61M   5/34  \	4	4	4C066	A61M   5/34	466	ˤ礹뤿ι¤Σ	Constructions for connecting the needle [2]
A61M   5/34 500 \	5	5	4C066	A61M   5/34	226	˥˥塼ο˥ϥ֤ؤΡϿ˥ϥ֤ѤʤʹΥؤľŪʷʣͣȡͣͥ	directly combining needle cannula to needle hub or, for syringe without needle hub, to nozzle of syringe (A61M5/32, 510H; A61M5/34, 550 takes precedence)
A61M   5/34 510 \	5	5	4C066	A61M   5/34	313	ɲäʤѤΡ㡥ץ󥰡ϥå	using additional part, e.g. clamp ring or collet
A61M   5/34 520 \	5	5	4C066	A61M   5/34	83	໤ΤΡʣͣͥ	friction type (A61M5/34, 510 takes precedence)
A61M   5/34 530 \	5	5	4C066	A61M   5/34	244	žΤΡ㡥Хͥåϥͥʣͣͥ	rotation type, e.g. bayonet or screw (A61M5/34, 510 takes precedence)
A61M   5/34 540 \	5	5	4C066	A61M   5/34	61	ʥåץå㡥˥֥˲ž뤳Ȥˤ礹Ρʣͣͥ	snap lock, e.g. joining together by rotating needle assembly to direction of axis (A61M5/34, 510 takes precedence)
A61M   5/34 550 \	5	5	4C066	A61M   5/34	72	ޤѤ	using adhesive agent
A61M   5/36  \	1	1	4C066	A61M   5/36	282	ؤζޤͤӽޤɻߤ뤿μʤͭΡΣ	with means for eliminating or preventing injection or infusion of air into body
A61M   5/36 500 \	2	2	4C066	A61M   5/36	239	֡ʣͣͥ	air detecting device (A61M5/168, 514 takes precedence)
A61M   5/36 510 \	2	2	4C066	A61M   5/36	64		drip tube accessory preventing entrance of air into blood vessel
A61M   5/38  \	2	2	4C066	A61M   5/38	86	ƿޤ¿Υե륿ѤΡΣ	using hydrophilic or hydrophobic filters
A61M   5/38 500 \	3	3	4C066	A61M   5/38	131	¿ե륿ѤΡӿˣͣ֡	using hydrophobic filter (bottle needle A61M5/162, 500V)
A61M   5/40  \	2	2	4C066	A61M   5/40	94	¢ƴ狼ΤήǤ뤿̤ۤѤΡΣ	using low-level float-valve to cut off media flow from reservoir
A61M   5/42  \	1	1	4C066	A61M   5/42	52	æΤΡɤưפˤ뤿򲡤ФΡޤϿΤɤ뤿μʤͭΡΣ	having means for desensitising skin, for protruding skin to facilitate piercing, or for locating point where body is to be pierced
A61M   5/42 500 \	2	2	4C066	A61M   5/42	76	δ٤򲼤	decrease skin sensitivity
A61M   5/42 510 \	2	2	4C066	A61M   5/42	142	ɤưפˤ褦夲Ρ㡥̮	make needling easier by heap up skin, e.g. decompressing cylinder, vein fixing means
A61M   5/42 520 \	2	2	4C066	A61M   5/42	171	Τɤ֤ꤹΡ㡥ĶȤѤ̮ʡ̥ƥץ졼	facor determnining needling psition, e.g. means to determine vein by using ultrasonic, injection position template
A61M   5/44  \	1	1	4C066	A61M   5/44	82	֤ޤΤѤޤϲǮ뤿μʤͭΡΣ	having means for cooling or heating the devices or media
A61M   5/44 500 \	2	2	4C066	A61M   5/44	102	ò	heating device
A61M   5/44 510 \	3	3	4C066	A61M   5/44	169	ò桤㡥ٸ	heating control, e.g. temperature detection device
A61M   5/44 520 \	3	3	4C066	A61M   5/44	123	òΤꤵƤ	heating medum being specified
A61M   5/44 522 \	4	4	4C066	A61M   5/44	125	ǮޤϤǮƳΤȤȹ碌Τ͢͢ϩò	heating infusion/blood infusion passage by using electgrically heated wire alone or its combination with thermal conductor
A61M   5/46  \	1	1	4C066	A61M   5/46	349	ο椹뤿μʤͭΡΣ	having means for controlling depth of insertion
A61M   5/48  \	1	1	4C066	A61M   5/48	37	ϤѹĴᡤؼޤ¤뤿μʤͭΡʣͣͥˡΣ	having means for varying, regulating, indicating or limiting injection pressure (A61M  5/142 takes precedence);;
A61M   5/48 500 \	2	2	4C066	A61M   5/48	73	ѲΡ㡥®٤Ѳ	changes injection pressure, e.g. changes injection speed
A61M   5/48 510 \	2	2	4C066	A61M   5/48	81	Ĵ᤹	adjusts injectoin pressure
A61M   5/48 520 \	2	2	4C066	A61M   5/48	30	ؼ	instructs injection pressure
A61M   5/50  \	1	1	4C066	A61M   5/50	240	٤λѤɻߤ뤿μʡޤϷ١ѺѤߡѡ̤ݤؼ뤿μʤͭΡΣ	having means for preventing re-use, or for indicating if defective, used, tampered with or unsterile
A61M   5/50 500 \	2	2	4C066	A61M   5/50	62	ʹؤʽŶɻߤ뤿ˡԥȥήϩ˸ʤͭ	having means to interferewith piston or fluid access to prevent wrongful filling of syringe
A61M   5/50 502 \	3	3	4C066	A61M   5/50	84	ԥȥ˸뤿Τ	to interfere with piston
A61M   5/50 510 \	2	2	4C066	A61M   5/50	99	ԥȥȥԥȥʬΥˤäƺƻѤɻߤʤͭ	having means to prevent re-use by separating piston and piston rod
A61M   5/50 520 \	2	2	4C066	A61M   5/50	38	ԥȥΥ˲뤳ȤˤäƺƻѤɻߤʤͭΡ㡥̤	having means to prevent re-use by destroying piston seal, e.g. piercing through
A61M   5/50 530 \	2	2	4C066	A61M   5/50	173	١ѺѤߡѡ̤ݤɽ뤿Τ	for displaying defect, used, unjust modification or non-sterilization
A61M   5/52  \	1	1	4C066	A61M   5/52	50	ɪݤΣ	Arm-rests
A61M   9/00  \	0	0	4C066	A61M   9/00	2	ǹԤʤĲΤ	Baths for subaquatic intestinal cleaning
A61M  11/00  \	0	0	4C103	A61M  11/00	48	ä˼ŪŬ륹ץ졼ޤϥȥޥ	Sprayers or atomisers specially adapted for therapeutic purposes
A61M  11/00  A	0	0	4C103	A61M  11/00	351	ץϥȥޥݰ	Sprays or atomizers
A61M  11/00  D	0	0	4C103	A61M  11/00	911	ʮ̸Υ뤫ðΤήФΡ̥ߥȤȶ˶ήФΤϣ	Discharging pressurized liquid from spray nozzle (discharging air in addition to mist 11/02)
A61M  11/00  F	0	0	4C103	A61M  11/00	218	¶¾ʮ̸ˤ	Using other spraying mechanisms
A61M  11/00  K	0	0	4C103	A61M  11/00	177	äѤ˹פ	Devised for instillation in particular
A61M  11/00  Z	0	0	4C103	A61M  11/00	247	¾Τ	Others
A61M  11/00 300 \	1	1	4C103	A61M  11/00	40	ĶȤѤ	Using supersonic
A61M  11/00 300 A	1	0	4C103	A61M  11/00	237	ưҤ˱դ̤ŤƳʤͭ	Having means for drawing liquid to oscillator in small quantities
A61M  11/00 300 D	1	0	4C103	A61M  11/00	118	β˿ưҤߤ	Having oscillator under the liquid tank
A61M  11/00 300 F	1	0	4C103	A61M  11/00	108	Ȥ̤˿ưã	Equipped with liquid tank separate from liquid medicine tank for conveying vibration
A61M  11/00 300 Z	1	0	4C103	A61M  11/00	199	¾Τ	Others
A61M  11/02  \	1	1	4C103	A61M  11/02	43	ʮ̸Τ˶ѤƹԤʤ	operated by air pressure applied to the liquid to be sprayed or atomised
A61M  11/02  A	1	0	4C103	A61M  11/02	49	٥ݺѤѤ	Using venturi action
A61M  11/02  C	1	1	4C103	A61M  11/02	124	յۤ夲ɤȥή̴ɤƱǤʤ	With liquid suction pipe and gas distribution pipe not on the same axis
A61M  11/02  E	1	2	4C103	A61M  11/02	92	ξɤĽХϥ˼Ǽ줿	With both pipes not stored inside outpocketing housing
A61M  11/02  G	1	2	4C103	A61M  11/02	93	ѥȤȢ˷Ρ㡥ѵ	Formed into a compact box shape, e.g. home suction equipment
A61M  11/02  K	1	1	4C103	A61M  11/02	100	յۤ夲ɤȥή̴ɤƱˤʤĤƤ	With liquid suction pipe and gas distribution pipe on the same axis
A61M  11/02  Z	1	0	4C103	A61M  11/02	251	¾ΤΡʮ̸Υ뤫ðήΤήФΤϣġ	Others (discharging pressurized air from the spray nozzle 11/00D)
A61M  11/04  \	1	1	4C103	A61M  11/04	96	ʮ̸Τ˾ѤƹԤʤ	operated by the vapour pressure of the liquid to be sprayed or atomised
A61M  11/04 300 \	2	2	4C103	A61M  11/04	3	ȯħͭ	Characterized by steam generating section
A61M  11/04 300 A	2	0	4C103	A61M  11/04	177	Ǯ	Heating members
A61M  11/04 300 E	2	0	4C103	A61M  11/04	19	塤롤̸˴ؤ	Related to irrigation, water supply, water level detection
A61M  11/04 300 G	2	0	4C103	A61M  11/04	15		Safety valves
A61M  11/04 300 J	2	0	4C103	A61M  11/04	46	ǮΤۤ弼ߤ	Having water reservoir room in addition to water heating room
A61M  11/04 300 Z	2	0	4C103	A61M  11/04	100	¾Τ	Others
A61M  11/04 310 \	2	2	4C103	A61M  11/04	76	ƳʾȯȤϢʬޤˤħͭ	Characterized by steam derivation section (including juncture area with steam generating section)
A61M  11/04 320 \	2	2	4C103	A61M  11/04	38	αħͭ	Characterized by liquid medicine storage section
A61M  11/04 330 \	2	2	4C103	A61M  11/04	21	Ƴħͭ	Characterized by liquid medicine derivation section
A61M  11/04 340 \	2	2	4C103	A61M  11/04	3	ߥȰħͭ	Characterized by mist guiding section
A61M  11/04 340 A	2	0	4C103	A61M  11/04	55	Ѱ̲ǽʤ	With modifiable guiding section
A61M  11/04 340 Z	2	0	4C103	A61M  11/04	83	¾Τ	Others
A61M  11/04 350 \	2	2	4C103	A61M  11/04	2	Ū֤ħͭ	Characterized by relative placement of each member
A61M  11/04 350 A	2	0	4C103	A61M  11/04	60	ΥեΥ	Steam nozzle and liquid medicine nozzle
A61M  11/04 350 Z	2	0	4C103	A61M  11/04	160	¾Τ	Others
A61M  11/06  \	1	1	4C103	A61M  11/06	158	󥸥Τ	of the injector type
A61M  11/08  \	2	2	4C103	A61M  11/08	193	󥸥Υݥåȥȥޥ	Pocket atomisers of the injector type
A61M  13/00  \	0	0	4C103	A61M  13/00	952	ŤޤϾǤŪȤ	Insufflators for therapeutic or disinfectant purposes
A61M  15/00  \	0	0	4C103	A61M  15/00	101		Inhalators
A61M  15/00  A	0	0	4C103	A61M  15/00	385	ε޴ͭޤ	Inhalation of steam (including steam containing medicine)
A61M  15/00  Z	0	0	4C103	A61M  15/00	2089	¾Τ	Others
A61M  15/02  \	1	1	4C103	A61M  15/02	4	ޤϥ󲽥ͭΡ	with activated or ionized gases; Ozone-inhalators
A61M  15/02  A	1	0	4C103	A61M  15/02	46		Ozone inhalation
A61M  15/02  B	1	0	4C103	A61M  15/02	21		Ozone injection
A61M  15/02  C	1	0	4C103	A61M  15/02	16	ѥ	Ozone pipe
A61M  15/02  Z	1	0	4C103	A61M  15/02	103	¾Τ	Others
A61M  15/06  \	1	1	4C103	A61M  15/06	39	մ洬ХޤϥѥפΤ褦ʷε	Inhaling appliances shaped like cigars, cigarettes or pipes
A61M  15/06  A	1	0	4C103	A61M  15/06	570	Τ	Tube-shaped
A61M  15/06  B	1	0	4C103	A61M  15/06	55	ޥɥѥ׷Τ	Big-bowled pipe-shaped
A61M  15/06  C	1	0	4C103	A61M  15/06	372	ʱ줬ǽʤ	Can be used for smoking
A61M  15/06  Z	1	0	4C103	A61M  15/06	74	¾ΤΡ̥ѥפϣá	Others (ozone pipes 15/02 C)
A61M  15/08  \	1	1	4C103	A61M  15/08	559	ɡˤ	Inhaling devices inserted into the nose
A61M  16/00  \	0	0	4C103	A61M  16/00	229	μ谷ˤäƴԤθƵ۴Ϥ˱ƶͿ֡㡥֡Ŵ٣ȣˡƻɡΣ	Devices for influencing the respiratory system of patients by gas treatment, e.g. ?ventilators (iron lungs A61H 31/02); Tracheal tubes
A61M  16/00 300 \	1	1	4C103	A61M  16/00	34	ƵۥݥɤˤĤħŤ͹Ƶ	Respirators characterized by respiration modes
A61M  16/00 305 \	2	2	4C103	A61M  16/00	47	ȯƵۡ㡥³۰Ƶ	Spontaneous respiration, e.g. continuous positive-pressure type respiration
A61M  16/00 305 A	2	0	4C103	A61M  16/00	926	³۰Ƶ	Continuous positive-pressure type respiration
A61M  16/00 305 B	2	0	4C103	A61M  16/00	357	ǵ̣֡äͥ	Oxygen inhalation devices (C takes precedence)
A61M  16/00 305 C	2	0	4C103	A61M  16/00	151	۵Τߥ뤵Ρʤ̤Ĵ᤹Τϣͣʬह	Supplying gas only during inspiration (adjusting ventilation volume classified under A61M16/00 315)
A61M  16/00 305 Z	2	0	4C103	A61M  16/00	93	¾Τ	Others
A61M  16/00 310 \	2	2	4C103	A61M  16/00	68	ĴƵۡʴԤθƵۥȤϴطʤڤӴ̤ĴΡ	Adjusted respiration (machine adjusting number and volume of ventilations regardless of patient's respiration cycle)
A61M  16/00 311 \	3	3	4C103	A61M  16/00	101	̵Ƶ۴ԤΤΤ¨֡ʼưˤ	For apneic patients, i.e. resuscitators (manual resuscitators 16/00 390)
A61M  16/00 312 \	3	3	4C103	A61M  16/00	18	Ƶ˴ԥȥꥬݤȵ۵˰ܹԤ	Moving to inspiration phase if there is patient trigger in inspiration phase
A61M  16/00 315 \	2	2	4C103	A61M  16/00	308	ƵۡʴԤθƵۥƱƸƵۥΡ	Assisted respiration (sending respiration gas by synchronizing with patient's respiration cycle)
A61M  16/00 320 \	2	2	4C103	A61M  16/00	23	ȯƵۤĴƵۡƵž	Superpositioning adjusted respiration and assisted respiration on spontaneous respiration
A61M  16/00 320 A	2	0	4C103	A61M  16/00	23	ĴƵۤžΡ̣ɣͣ֡	Superpositioning adjusted respiration (IMV)
A61M  16/00 320 B	2	0	4C103	A61M  16/00	78	ƵۤžΡ̣ɣ֡	Superpositioning assisted respiration (IAV)
A61M  16/00 320 Z	2	0	4C103	A61M  16/00	34	¾Τ	Others
A61M  16/00 325 \	2	2	4C103	A61M  16/00	83	ٸƵ	High-frequency respiration
A61M  16/00 328 \	2	2	4C103	A61M  16/00	10	ݥѴǽʤ	Capable of mode conversion
A61M  16/00 328 A	2	0	4C103	A61M  16/00	39	Ԥ̵ƵۤˤĤƥݥѴԤ	Performing mode conversion through apneic state of patients
A61M  16/00 328 B	2	0	4C103	A61M  16/00	17	ȯƵۤ¾ΥݥɡʼȯƵۤ¾Υݥɤνžϣͣ	Spontaneous respiration and other modes (superposition of spontaneous respiration and other modes A61M16/00 320)
A61M  16/00 328 Z	2	0	4C103	A61M  16/00	46	¾Τ	Others
A61M  16/00 332 \	2	2	4C103	A61M  16/00	1	Ƶħͭ	Characterized by final pressure of inspiration
A61M  16/00 332 A	2	0	4C103	A61M  16/00	86	Уţţ	PEEP
A61M  16/00 332 Z	2	0	4C103	A61M  16/00	6	¶¾Τ	Others
A61M  16/00 335 \	2	2	4C103	A61M  16/00	26	¾Υݥ	Other modes
A61M  16/00 340 \	1	1	4C103	A61M  16/00	89	۵Ƶη¨ڤӴ̤ĴˡˤĤħŤ͹Ƶ	Respirators characterized by formation of inspiration/exhalation cycles, i.e. adjustment method of number and volume of ventilation
A61M  16/00 343 \	2	2	4C103	A61M  16/00	322	Ϥ˴ŤĴ	Adjusted according to pressure
A61M  16/00 345 \	2	2	4C103	A61M  16/00	169	ή̤˴ŤĴ	Adjusted according to flow rate
A61M  16/00 347 \	3	3	4C103	A61M  16/00	68	ƴʥ٥ݥޡԥȥˤ˰Ū˥α	Temporarily storing gas in variable capacity container (bellows, bags, pistons)
A61M  16/00 350 \	4	4	4C103	A61M  16/00	18	ƴζưħͭ	Characterized by driving of variable capacity containers
A61M  16/00 350 A	4	0	4C103	A61M  16/00	6	ήΤˤư	Drive using fluids
A61M  16/00 350 Z	4	0	4C103	A61M  16/00	19	¾Τ	Others
A61M  16/00 355 \	3	3	4C103	A61M  16/00	59	ˤꥬζֵڤӶ̤Ĵ᤹	Adjusting time and volume of gas supply by valves etc.
A61M  16/00 355 A	3	0	4C103	A61M  16/00	58	̲ѡƴڤӡϡ̲ѡ͹ʤޤϩѤۤĤ	Opening and closing valves by using air pressure circuit containing (variable) containers and/or (variable) diaphragms
A61M  16/00 355 Z	3	0	4C103	A61M  16/00	72	¾Τ	Others
A61M  16/00 360 \	3	3	4C103	A61M  16/00	12	Ԥ˶뤷̤ѻɸͤãȤ۵򽪤餻	Adding volume of gas supplied to patients and terminating inspiration phase after reaching the target value
A61M  16/00 363 \	3	3	4C103	A61M  16/00	7	۵ˤƥ̤Ǥʤ	With fluctuating gas volume in inspiration phase
A61M  16/00 366 \	3	3	4C103	A61M  16/00	72	Ϥ˴ŤĴή̤˴ŤĴΤ⤬ǽʤ	Capable of adjustment based on pressure and adjustment based on flow rate
A61M  16/00 370 \	1	1	4C103	A61M  16/00	74	͹Ƶ֤ˤƻ롦	Monitoring/alarm in respirators
A61M  16/00 370 A	1	0	4C103	A61M  16/00	155	ή̷	Flow meters
A61M  16/00 370 Z	1	0	4C103	A61M  16/00	702	¾Τ	Others
A61M  16/00 375 \	1	1	4C103	A61M  16/00	128	͹Ƶ֤ˤ۵ؤޤź	Addition of medicines to inspiration gas in respirators
A61M  16/00 380 \	1	1	4C103	A61M  16/00	411	͹Ƶ֤ˤ¤ʣͣʬवΤ	Detailed structure in respirators (excluding those classified under A 61 M 16/04-16/22)
A61M  16/00 390 \	1	1	4C103	A61M  16/00	10	ưƵ۴­Ƨ߼ޤ	Manual respirators (including stepping type)
A61M  16/00 390 A	1	0	4C103	A61M  16/00	47	ݥХĥͭ	Having squeeze bags
A61M  16/00 390 Z	1	0	4C103	A61M  16/00	50	¾Τ	Others
A61M  16/00 395 \	1	1	4C103	A61M  16/00	37	ĤƵ۴	Mouth-to-mouth respirators
A61M  16/01  \	1	1	4C103	A61M  16/01	22	äŬΡΣ	specially adapted for anaesthetising [4]
A61M  16/01  A	1	0	4C103	A61M  16/01	92	ϩħͭ	Characterized by anaesthetising circuit
A61M  16/01  D	1	1	4C103	A61M  16/01	66	ãϢƵͭƻѷΤ	Re-use type having CO2 respiration tube
A61M  16/01  F	1	0	4C103	A61M  16/01	37	ϩؤε˥ĥμդħͭ	Characterized by installation of vaporizer unit to anaesthetic circuit
A61M  16/01  G	1	0	4C103	A61M  16/01	67	¬	Depth measurement
A61M  16/01  K	1	0	4C103	A61M  16/01	27	Хȥ֥ĥ	Bite block
A61M  16/01  M	1	0	4C103	A61M  16/01	76	ӥ	Exhaust treatment
A61M  16/01  Z	1	0	4C103	A61M  16/01	170	¾Τ	Others
A61M  16/04  \	1	1	4C103	A61M  16/04	57	ƻɡΣ	Tracheal tubes [4]
A61M  16/04  A	1	0	4C103	A61M  16/04	334	դħͭ	Characterized by cuff
A61M  16/04  Z	1	0	4C103	A61M  16/04	1078	¾Τ	Others
A61M  16/06  \	1	1	4C103	A61M  16/06	47	ƵۤޤޥΣ	Respiratory or anaesthetic masks [4]
A61M  16/06  A	1	0	4C103	A61M  16/06	1451	ޥ	Face mask
A61M  16/06  B	1	0	4C103	A61M  16/06	27	顦Ƭƥ	Face/head tent
A61M  16/06  C	1	0	4C103	A61M  16/06	489	ɡ˥ݥ	Nostril cannula
A61M  16/06  D	1	0	4C103	A61M  16/06	280	ޥԡݥ	Mouth piece
A61M  16/06  Z	1	0	4C103	A61M  16/06	287	¾Τ	Others
A61M  16/08  \	1	1	4C103	A61M  16/08	30	ʢϢɡΣ	Bellows; Connecting tubes [4]
A61M  16/08 300 \	2	2	4C103	A61M  16/08	21	ʢ	Bellows
A61M  16/08 300 A	2	0	4C103	A61M  16/08	41	Ʊ	Coaxial tubes
A61M  16/08 300 C	2	0	4C103	A61M  16/08	25	ʢλٻ㥹ɡ	Support for bellows
A61M  16/08 300 Z	2	0	4C103	A61M  16/08	85	¾Τ	Others
A61M  16/08 330 \	2	2	4C103	A61M  16/08	235	ϢɵڤӷѼ	Connecting pipes and joints
A61M  16/10  \	1	1	4C103	A61M  16/10	35	ƵۥޤϾĴΣ	Preparation of respiratory gases or vapours [4]
A61M  16/10  A	1	0	4C103	A61M  16/10	249	ѻȯ	Medical oxygen generating devices
A61M  16/10  B	1	0	4C103	A61M  16/10	1272	ѻǻ̡ٲ	Medical oxygen concentrating (enriching) devices
A61M  16/10  C	1	0	4C103	A61M  16/10	134	βò	Heating of gas
A61M  16/10  D	1	0	4C103	A61M  16/10	46	λǤθƵۥĴ	Adjustment of respiratory gases from liquid oxygen
A61M  16/10  Z	1	0	4C103	A61M  16/10	469	¾Τ	Others
A61M  16/12  \	2	2	4C103	A61M  16/12	346	Ƽ塞򺮹礹뤳ȤˤΡΣ	by mixing different gases [4]
A61M  16/14  \	2	2	4C103	A61M  16/14	3	ΤΣĤϱʤƼήΤ򺮹礹뤳ȤˤΡΣ	by mixing different fluids, one of them being in a liquid phase [4]
A61M  16/14  A	2	0	4C103	A61M  16/14	24	ũˤޤθƵۥؤź	Addition of liquid anaesthetics to respiratory gases through dripping, squeezing
A61M  16/14  B	2	0	4C103	A61M  16/14	33	㤨еؤαޤνŶ	Filling of liquid anaesthetics to anaesthetic devices such as vaporizers
A61M  16/14  Z	2	0	4C103	A61M  16/14	39	¾Τ	Others
A61M  16/16  \	3	3	4C103	A61M  16/16	38	Ƶ۵ü֡Σ	Devices to humidify the respiration air [4]
A61M  16/16  A	3	0	4C103	A61M  16/16	386	βǮˤĤȯѤ	Using vapor generated by heating water
A61M  16/16  B	3	1	4C103	A61M  16/16	31	ĥѤ	Using wicks
A61M  16/16  C	3	0	4C103	A61M  16/16	75	ƩѤΡ̲ͥ	Using vapor permeable membrane (below takes precedence)
A61M  16/16  D	3	0	4C103	A61M  16/16	111	򥬥̲᤹	With gas passing through water
A61M  16/16  E	3	1	4C103	A61M  16/16	47	ʬʪ򥬥̲᤹	With gas passing through water adsorbents
A61M  16/16  F	3	0	4C103	A61M  16/16	70	Ƶȵ۵δ֤μʬ򴹤ˤ	With humidity exchange between exhalation and inhalation
A61M  16/16  Z	3	0	4C103	A61M  16/16	221	¾Τ	Others
A61M  16/18  \	3	3	4C103	A61M  16/18	1	ĴʪѤξȯ֡Σ	Vaporising devices for anaesthetic preparations [4]
A61M  16/18  B	3	0	4C103	A61M  16/18	22	Ƶۥޤξ̶֤̲ᤵ	Having respiratory gases pass through space of upper liquid anaesthetic
A61M  16/18  C	3	1	4C103	A61M  16/18	39	Ƶۥ嵭̶֤ǤϤʤ¾ϩ̤	Having respiratory gases pass through space of the above upper liquid anaesthetic
A61M  16/18  D	3	0	4C103	A61M  16/18	17	Ƶۥޤ̲ᤵ	Having respiratory gases pass through liquid anaesthetics
A61M  16/18  Z	3	0	4C103	A61M  16/18	37	¾Τ	Others
A61M  16/20  \	1	1	4C103	A61M  16/20	20	ѸƵ֤äŬۡΣ	Valves specially adapted to medical respiratory devices [4]
A61M  16/20  A	1	0	4C103	A61M  16/20	66	ǥޥ	Demand valves
A61M  16/20  B	1	0	4C103	A61M  16/20	99	Ƶ	Inspiration valves
A61M  16/20  C	1	0	4C103	A61M  16/20	33	Уţţ	PEEP valves
A61M  16/20  D	1	0	4C103	A61M  16/20	103	Ƶ	Respiration valves
A61M  16/20  E	1	0	4C103	A61M  16/20	29	ήĴ	Mixed fluid adjustment valves
A61M  16/20  F	1	0	4C103	A61M  16/20	104	ήĴ	Flow rate adjustment valves
A61M  16/20  G	1	0	4C103	A61M  16/20	41		Safety valves
A61M  16/20  H	1	0	4C103	A61M  16/20	59	ڤ괹	Switching valves
A61M  16/20  J	1	0	4C103	A61M  16/20	30		Decompression valves
A61M  16/20  Z	1	0	4C103	A61M  16/20	126	¾Τ	Others
A61M  16/22  \	1	1	4C103	A61M  16/22	58	úǵۼ֡Σ	Carbon dioxide-absorbing devices [4]
A61M  19/00  \	0	0	4C103	A61M  19/00	156	֡β֡ʣͣͥˡΣ	Devices for local anaesthesia; Devices for hypothermia () [2]
A61M  21/00  \	0	0	4C105	A61M  21/00	73	ռξ֤Ѳ򵯤뤽¾֤ޤˡŪŪޤϲŪʤˤä̲ޤϽ餻֡㡥̲ΤΤΡ̲¥ʤ٥åɣǣ	Other apparatus or methods to cause a change in the state of consciousness; Devices for producing or ending sleep by mechanical, optical, or acoustical means, e.g. for hypnosis (beds for promoting sleep A61G 7/043)
A61M  21/00  A	0	0	4C105	A61M  21/00	350	ä˴ؤ	Related to awakening
A61M  21/00  B	0	1	4C105	A61M  21/00	403	եɥХåԤ	Giving feedback
A61M  21/00  Z	0	0	4C105	A61M  21/00	193	¾Τ	Others
A61M  21/02  \	1	1	4C105	A61M  21/02	14	̲ޤϥ饯Ͷȯ뤿ΤΡ㡥ľŪлɷ㡤̵̲ˡˤΡʥޥåΤΤΣȡŵţΡ㡥Ƴ뤿ήޤϴַήŬѤΣΣˡΣ	for inducing sleep or relaxation, e.g. by direct nerve stimulation, hypnosis, analgesia(for massage A61H; electrotherapy A61N, e.g. applying alternating or intermittent electric currents for producing anaesthesia A61N1/34) [5]
A61M  21/02  A	1	0	4C105	A61M  21/02	276	̲˴ؤ	Related to sleep
A61M  21/02  B	1	1	4C105	A61M  21/02	215	ɷͿ	Giving light stimulation
A61M  21/02  C	1	1	4C105	A61M  21/02	256	ɷͿ	Giving sound stimulation
A61M  21/02  D	1	1	4C105	A61M  21/02	72	ŵɷͿΡ㡥Ȥˤ	Giving electric stimulation, e.g. low frequency
A61M  21/02  E	1	1	4C105	A61M  21/02	117	ʾλɷͿ	Giving two or more types of stimulation
A61M  21/02  F	1	1	4C105	A61M  21/02	10	̴˴ؤ	Related dreams
A61M  21/02  G	1	1	4C105	A61M  21/02	371	եɥХåԤ	Giving feedback
A61M  21/02  H	1	0	4C105	A61M  21/02	1050	ϥå	Mental activation or relaxation
A61M  21/02  J	1	1	4C105	A61M  21/02	666	եɥХåԤ	Giving feedback
A61M  21/02  Z	1	0	4C105	A61M  21/02	41	¾Τ	Others
A61M  25/00  \	0	0	4C267	A61M  25/00	692	ơƥ롨õˡ¬ޤϸѣ¡	Catheters; Hollow probes (for measuring or testing A61B)
A61M  25/00 500 \	1	1	4C267	A61M  25/00	1018	ơƥ롤¾ΰѤޤϼѥ塼֤ˡ	manufacturing method of catheter, other medical or surgical use tube
A61M  25/00 502 \	2	2	4C267	A61M  25/00	295	ơƥüη㡥ü̼βù³ޤ	formation of tip of catheter, e.g. processing, connecting or  gradually diminishing break corner
A61M  25/00 504 \	2	2	4C267	A61M  25/00	488	ޤ줿¤ͭΡ㡥롤ȡå塤ȥɤޤƩ	having embeded structure, e.g. coil, braid, mesh, strand or radiation impermeable coil
A61M  25/00 506 \	2	2	4C267	A61M  25/00	193	塼֤ȥϥ֤Ϣ	connecting tube and hub
A61M  25/00 510 \	1	1	4C267	A61M  25/00	473	塼֤ηħΡʣͣͥ	characterized by shape of tube (A61M25/00, 630 takes precedence)
A61M  25/00 520 \	1	1	4C267	A61M  25/00	258	üħΡ㡥üʣͣͣͥ表Х롼󥫥ơƥͣ	characterized by distal end, e.g. at tip (A61M25/00, 630, A61M25/04 take precedence; baloon cartel A61M25/10)
A61M  25/00 530 \	2	2	4C267	A61M  25/00	1476	ơƥüŪħΡ㡥̵üѶüޤüι¤	characterized by static features of tip of catheter, e.g. shape, flawless, bent tip or tip structure
A61M  25/00 532 \	3	3	4C267	A61M  25/00	376	塼֤ȰΤǤʤü	tip not integrated with tube
A61M  25/00 534 \	3	3	4C267	A61M  25/00	1072	¦㡥سԤޤ¦ĺɤɻߤ뤿κ	side holes, e.g. its contour or arrrangement; measures to prevent side holes from being blocked
A61M  25/00 540 \	2	2	4C267	A61M  25/00	1128	ơƥüưŪħΡ㡥Ĳǽĥǽޤѷǽ	characterized by dynamic features of tip of catheter, e.g. able open and close, expand or change shape
A61M  25/00 542 \	3	3	4C267	A61M  25/00	235		valve
A61M  25/00 550 \	2	2	4C267	A61M  25/00	290	ơƥüζ٤ޤϽ˴ؤħ	characterized by strength or flexibility of tip of catheter
A61M  25/00 552 \	3	3	4C267	A61M  25/00	314	餫ü	soft tip
A61M  25/00 560 \	2	2	4C267	A61M  25/00	288	դǤΡ㡥äιФι¤Ŭ礹褦˷դǤ	able to change sghape, e.g. especially able to change shape to adapt to biological structure of cavities of the body
A61M  25/00 600 \	1	1	4C267	A61M  25/00	763	¤Ūħ	charaterized by structural features
A61M  25/00 610 \	2	2	4C267	A61M  25/00	1296	ʣؤʤΡ㡥ƥ󥰤줿	composed of multiple layers, e.g. coated
A61M  25/00 612 \	3	3	4C267	A61M  25/00	355	ư夵뤿Υƥ	coating to improve sliding capacity
A61M  25/00 620 \	2	2	4C267	A61M  25/00	966	ΤߺѤΡ㡥磻䡤롤	use of implant material for reinforcement, e.g. wire, coil, braid
A61M  25/00 622 \	3	3	4C267	A61M  25/00	294	Ūʶ㡥®򴹼ɥ磻ݡȡơƥʬΤߤζ	local enforcement, e.g. quick exchange guide wire port, enforcing specific part only of catheter
A61M  25/00 624 \	3	3	4C267	A61M  25/00	604	Ĺ꼴˱äѲͭΡ㡥ȤΥԥåѲ	having hardness which changes along a longitudinal axis, e.g. coil or braid with changed pitgch
A61M  25/00 630 \	2	2	4C267	A61M  25/00	342	ΰͭ	having a region to increase flexibility
A61M  25/00 632 \	3	3	4C267	A61M  25/00	241	ͭޤȼʥ塼ؤΡ㡥å	made from fenestrated materials or frail tube layers, e.g. slit
A61M  25/00 650 \	1	1	4C267	A61M  25/00	354	ɽ̤˻ǧǤޡͭΡʤŪˤǻǧǤΡ㡥ޡžޡϷ	having visually recognizable marks, i.e. visually recognizable by naked eyes for whatever the purpose, on surface, e.g. insertion depth marker, revolving marker or specification of type
A61M  25/00 690 \	1	1	4C267	A61M  25/00	88	쳰ơƥ	extradural catheter
A61M  25/01  \	1	1	4C267	A61M  25/01	421	ơƥƳ⡤ʡդޤݻΡʣͣͥˡΣ	Introducing, guiding, advancing, emplacing or holding catheters (A61M 25/10 takes precedence);;
A61M  25/01 500 \	2	2	4C267	A61M  25/01	433	®򴹤ޤϥΥ졼륫ơƥ	quick exchange or mono-rail catheter
A61M  25/01 510 \	2	2	4C267	A61M  25/01	487	䶯ѤƳޤϰ򤹤Ρ㡥åȤޤϥץåå	introduce or guide using internal reinforcement member, e.g. stilet or pushrod
A61M  25/02  \	2	2	4C267	A61M  25/02	156	ݻ֡㡥ξˡΣ	Holding devices for catheters
A61M  25/02 500 \	3	3	4C267	A61M  25/02	211	ơƥΤ˸ꤹ	eqipment to fix catheter on body
A61M  25/02 502 \	4	4	4C267	A61M  25/02	407	ơƥɽ̤¹Ԥ˸ꤹ	eqipment to fix catheter parallel to  body surface
A61M  25/02 504 \	4	4	4C267	A61M  25/02	288	ơƥɽ̤˿ľ˸ꤹ	eqipment to fix catheter perpendicular to body surface
A61M  25/02 510 \	3	3	4C267	A61M  25/02	155	ơƥ򵡴˸ꤹ	eqipment to fix catheter on device
A61M  25/04  \	3	3	4C267	A61M  25/04	559	ݻΡ㡥ıΡΣ	in the body, e.g. expansible
A61M  25/06  \	2	2	4C267	A61M  25/06	202	ɰˤޤΤΡʣͣͥˡΣ	Body-piercing guide needles or the like (A61M 25/088 takes precedence);;
A61M  25/06 500 \	3	3	4C267	A61M  25/06	1445	Сˡɥ뼰ơƥ륢֥ꡤ㡥ɣ֥ơƥ롤ơƥ륿פαֿˡˣͣɿˣ£	over-the-needle type catheter assembly, e.g. IV catheter, indwelling nndle (cannula A61M5/158, 500, trocar A61B17/34)
A61M  25/06 502 \	4	4	4C267	A61M  25/06	131	Сˡɥ뼰ơƥ륢֥¤ˡ	mannufactguring method of over-the-needle type catheter assembly
A61M  25/06 510 \	3	3	4C267	A61M  25/06	240	ˤݸ뤿ᡤޤϿˤ㡥󥰡ۥ	equipment to protect needle or to aid insertion of needle, e.g. wing, holder
A61M  25/06 512 \	4	4	4C267	A61M  25/06	489	ˤαüݸʤͭΡ㡥ˡɥ륬	having means to protect distal end of needle, e.g. needle guard
A61M  25/06 514 \	4	4	4C267	A61M  25/06	180	ĳޤ֡㡥ͶƳϥɥޤؤΤΤ	device of butterfly type or wing shape, e.g. for guiding handle or for adhesion to skin
A61M  25/06 550 \	3	3	4C267	A61M  25/06	1031	ɥ塼֡㡥ơƥ륤ȥǥ塼ɥ	guide tube, e.g. caheter introducer, guide sheath
A61M  25/06 552 \	4	4	4C267	A61M  25/06	48	ɥ塼֤¤ˡ	manufacturing method of guide tube
A61M  25/06 554 \	4	4	4C267	A61M  25/06	241	ʬǽǽʤ	separable, tearable
A61M  25/06 556 \	4	4	4C267	A61M  25/06	933	ơƥڤӳ塼֤ͭ륷ƥࡤ㡤꡼֤⤷ϥɥ塼	system containing catheter and external tube, e.g. sheath, sleeve or guide tube
A61M  25/06 580 \	3	3	4C267	A61M  25/06	221	եåХå	flash back chamber
A61M  25/08  \	2	2	4C267	A61M  25/08	74	ʼʡ㡥ϿʼΣ	Advancing means, e.g. self-propelled
A61M  25/08 500 \	3	3	4C267	A61M  25/08	244	Ūʼʡ㡥ơƥǥڥ󥵡	means to mechanically move forward, e.g. catheter dispencer
A61M  25/082  \	3	3	4C267	A61M  25/082	30	ʿ֡ʣͣͥˡΣ	Self-propulsion arrangements (A61M 25/085 takes precedence);;
A61M  25/082 500 \	4	4	4C267	A61M  25/082	47	ʿ֡㡥Χܥå	self-propelled device, e.g. autonomy robot
A61M  25/085  \	3	3	4C267	A61M  25/085	2	ήοʡΣ	Fluid propulsion
A61M  25/085 500 \	4	4	4C267	A61M  25/085	15	ήΤˤήζưϤήβϩˤĤ	having fluid drive source using external fluid within fluid circuit of release system
A61M  25/085 510 \	4	4	4C267	A61M  25/085	9	ήˤäƱ¤륫ơƥ롤㡥ѥ饷塼ȤͭΡΤ̤߷פ줿Х롼󥫥ơƥ	catheter carried by blood flow, e.g. having parachute; baloon catheter especially designed for this purpose
A61M  25/088  \	2	2	4C267	A61M  25/088	149	ɲäΥơƥѤΡ㡥ŪϤˤ̤Ϥ뤿Σ	using an additional catheter, e.g. to reach relatively inaccessible places
A61M  25/09  \	2	2	4C267	A61M  25/09	642	ɥ磻䡼Σ	Guide wires
A61M  25/09 500 \	3	3	4C267	A61M  25/09	441	ɥ磻¤ˡ	manufacturing method of guide wire
A61M  25/09 510 \	3	3	4C267	A61M  25/09	292	ͭΡ㡥ޥɥ롤	having a core, e.g. mandrill, core bar
A61M  25/09 512 \	4	4	4C267	A61M  25/09	54	饤ɼΥͭ	having a sliding core
A61M  25/09 514 \	4	4	4C267	A61M  25/09	338	ꤵ줿ͭΡ㡥ü˸ꤵ륳ĥ磻	having a fixed core, e.g. core fixed at point; pulling wire
A61M  25/09 516 \	4	4	4C267	A61M  25/09	1054	μϤ˥ͭ	having coil around a core
A61M  25/09 520 \	3	3	4C267	A61M  25/09	58	̵Ǥꡤȷ礵륳ͭ	having coil which may be combined with sheath but without a core
A61M  25/09 530 \	3	3	4C267	A61M  25/09	518	ɥ磻뤿ε	mechanism to insert guide wire
A61M  25/09 540 \	3	3	4C267	A61M  25/09	162	ơƥ㤷ϿΤФƸ֤˥ɥ磻ꤹ뤿	device to stabilize giude wire at fixed position against catheter or human body
A61M  25/09 550 \	3	3	4C267	A61M  25/09	942	Ǻ๽䥳ƥ󥰤ͭΡεŪ񤤤Ǻࡤ㡤Ťãȥ륯Ф붯	having specific material constitution or coating; materials having specific mechanical behavior, e.g. strength against hardness, transmitting tgorque
A61M  25/092  \	2	2	4C267	A61M  25/092	427	üαΣ	Remote control of the orientation of the distal end
A61M  25/092 500 \	3	3	4C267	A61M  25/092	1060	ưǽʵŪʤͭΡ㡥ĥ磻	having movablemechanical means, e.g. pulling wire
A61M  25/092 510 \	3	3	4C267	A61M  25/092	697	üαΤΥϥɥ	handle to remote control distal end part
A61M  25/095  \	2	2	4C267	A61M  25/095	729	ơƥ֤õΤΡ㡥ǤߤΡΣ	Arrangements for enabling the detection of the internal position of the catheter, e.g. radiographically
A61M  25/098  \	3	3	4C267	A61M  25/098	1189	ƩΥޡѤΡΣ	using radio-opaque markers
A61M  25/10  \	1	1	4C267	A61M  25/10	1718	Х롼󥫥ơƥʥƥȤޤϥƥȥեȤ֤뤿ĥǽʥХ롼ƣˡΣ	Balloon catheters (inflatable balloons for placing stents or stent-grafts A61F  2/958)
A61M  25/10 500 \	2	2	4C267	A61M  25/10	543	Х롼󥫥ơƥˡ	manufacturing method of baloon catheter
A61M  25/10 502 \	3	3	4C267	A61M  25/10	614	Х롼¤ˡ㡥֥ޤϥޥɥ˥Х롼ʣؤ򴬤դ뤳Ȥˤ	manufacturing method of baloon members, e.g. by blow molding,  extrusion molding, deposition or wrap multiple layers of baloon materials around mandrill
A61M  25/10 510 \	2	2	4C267	A61M  25/10	1557	Х롼ηħ	characterized by shape of baloon
A61M  25/10 512 \	2	2	4C267	A61M  25/10	375	ҤͭХ롼㡥ޤޤϴŤˤޤ	baloon with fold, e.g. baloon that can be fold up or fold up in layers
A61M  25/10 520 \	2	2	4C267	A61M  25/10	765	ʣΥХ롼ͭ륫ơƥ	catheter having multiple baloons
A61M  25/10 530 \	2	2	4C267	A61M  25/10	710	ơƥ塼֤ĥ塼֤Ȥδ֤η	joint between catheter tube and expansion tube
A61M  25/10 540 \	2	2	4C267	A61M  25/10	423	Х롼ĥޤĥ椹	device to expand or control expansion of baloon
A61M  25/10 542 \	3	3	4C267	A61M  25/10	237	ĥήΤХ롼Ƴ뤿μ	means to supply inflation fluid  into baloon
A61M  25/10 544 \	4	4	4C267	A61M  25/10	127	ư֤	uses manually operated device
A61M  25/10 546 \	4	4	4C267	A61M  25/10	150	ư֤	uses automatically operated device
A61M  25/10 550 \	2	2	4C267	A61M  25/10	1042	ɷΤ˻Ȥ	used for angiogenesis
A61M  25/12  \	2	2	4C267	A61M  25/12	67	ŬˤȤʬΥ֡Σ	Arrangements for detaching the balloon when in place
A61M  25/14  \	1	1	4C267	A61M  25/14	83	ήϩ֤ޤϷ㡥ʣήϩʣͣͥˡΣ	Arrangement or shape of fluid flow passages, e.g. of plural fluid passages (A61M 25/10 takes precedence);;
A61M  25/14 500 \	2	2	4C267	A61M  25/14	127	롼η㡥̡ѳ	shape of lumen, e.g. cross section, variable outer diameter
A61M  25/14 510 \	3	3	4C267	A61M  25/14	137	Ǥͭޥ롼󥫥ơƥ	multi-lumen catheter with fixed element
A61M  25/14 512 \	4	4	4C267	A61M  25/14	1173	¹Ԥ󤵤줿롼ħ	characterized by arrangement of lumen in parallel
A61M  25/14 514 \	4	4	4C267	A61M  25/14	550	Ʊ󤵤줿롼ħ	characterized by arrangement of lumen on same axis
A61M  25/14 516 \	4	4	4C267	A61M  25/14	167	ʤȤ⣱ĤüʷΥ롼ħΡ㡥¿ѷʱߡӷޤϱ	characterized by one or more lumen having special shape, e.g. polygon, ellipse, wedge-shape or uneven-shape
A61M  25/14 518 \	4	4	4C267	A61M  25/14	165	ȤΩƤ졤³ޤϷ礵ǤħΡ㡥ʬǽʥ塼֡롼㤷̸ĤΥ볰¦	characterized by elements of assembly, connection or joint, e.g. separable tube, lumen or individual core formed by outer sheath
A61M  25/16  \	1	1	4C267	A61M  25/16	61	¾ʬवʤ¤ޤΩΣ	Making or assembling not otherwise provided for
A61M  25/18  \	2	2	4C267	A61M  25/18	96	ơƥޤõˤΥϥ֤ؤμդΣ	Connecting catheters or probes to hubs
A61M  27/00  \	0	0	4C267	A61M  27/00	1698	ޤΤΡΤӱ֡ʽ򳫤֤ˤƤ֣£	Drainage appliances for wounds, or the like (implements for holding wounds open A61B 17/02)
A61M  29/00  \	0	0	4C267	A61M  29/00	2130	Ρ㡥ޡƳʤͭޤͭʤĥΣ	Dilators with or without means for introducing media, e.g. remedies[2006.01]
A61M  29/02  \	1	1	4C267	A61M  29/02	3523	ıĥʤդΤؤۤμդ£ãˡĽǽʺǺ줿ĥΣ	Inflatable dilators (connection of valves to inflatable elastic bodies B60C 29/00); Dilators made of swellable materials [3]
A61M  29/04  \	2	2	4C267	A61M  29/04	48	ĽǽʺǺ줿ĥΣ	Dilators made of swellable materials [5]
A61M  31/00  \	0	0	4C066	A61M  31/00	2277	ιΡ㡥ޡƳޤα֤֡ʣͣͥˡΣ	Devices for introducing or retaining media, e.g. remedies, in cavities of the body (A61M 25/00 takes precedence) [2,5]
A61M  35/00  \	0	0	4C267	A61M  35/00	996	ξΡ㡥ޡŬѡ㡥ۤ뤿֡ʲޤ谷֣ġۼХåɡ㡥ƣˡΣ	Devices for applying media, e.g. remedies, on the human body (devices for handling toiletry or cosmetic substances A45D; absorbent pads, e.g. swabs, A61F 13/15) [2006.01]
A61M  35/00  X	0	0	4C267	A61M  35/00	558	ʵ̥ĥ֡	Cotton swabs, cotton balls (swabs)
A61M  35/00  Z	0	0	4C267	A61M  35/00	1967	¾Τ	Others
A61M  36/00  \	0	0	4C267	A61M  36/00	4	ΤؤʪŬѡΣ	Applying radioactive material to the body [5]
A61M  36/02  \	1	1	4C267	A61M  36/02	6	¾͸ޤưͥ륮㡥żǮޥȤȷ礷ΡΣ	combined with other radiant- or wave-energy source, e.g. electromagnetic, thermal, micro-wave [5]
A61M  36/04  \	1	1	4C267	A61M  36/04	220	ʪ֡㡥ޤΤäŬ礵֡Σ	Arrangements specially adapted for placing, e.g. inhaling or injecting, radioactive material within the body [5]
A61M  36/06  \	2	2	4C267	A61M  36/06	306	Τ˻ɤ̤Ƴɤޤޤʺޤή뤳ȤˤΡΣ	by fluid injection of radioactive or enhancing agent through a body-piercing conduit [5]
A61M  36/08  \	3	3	4C267	A61M  36/08	123	ή¢μá㡥󥸤μáΣ	Fluid reservoir shielding, e.g. syringe shielding [5]
A61M  36/10  \	2	2	4C082	A61M  36/10	68	ҵܰ紤ޤϹפؤŬѡΣ	Utero-vaginal or pelvic application [5]
A61M  36/12  \	2	2	4C082	A61M  36/12	470	ɤޤϥץȤۥ㡥ץΣ	Injectors, holders for seeds or implants, e.g. capsules [5]
A61M  36/14  \	1	1	4C082	A61M  36/14	122	ʤʡΣ	Radioactive dressings [5]
A61M  37/00  \	0	0	4C267	A61M  37/00	2932	ΤƳ뤽¾֡ޤϼΤΤΣ£ŵƳˡޤϥƩˡΤ֣ΣˡŪʤ椫γȻˤäƿޤƳΡʱȣˡΣ	Other apparatus for introducing media into the body (apparatus for iontophoresis or cataphoresis A61N 1/30); Percutany, i.e. introducing medicines into the body by diffusion through the skin (salt baths A61H 33/04)
A61M  37/00 500 \	1	1	4C267	A61M  37/00	225	ޥˡɥ	micro needle
A61M  37/00 505 \	2	2	4C267	A61M  37/00	768	ޥˡɥ¤ˡ	manufacturung method of micro needle
A61M  37/00 510 \	2	2	4C267	A61M  37/00	512	ޥˡɥѤƳ	medicine introducer using micro-needle
A61M  37/00 512 \	3	3	4C267	A61M  37/00	138	¢ͭ	contains internally medicine storage tank
A61M  37/00 514 \	4	4	4C267	A61M  37/00	395	ޥˡɥήϩͭ	flow channel inside of micro-needle
A61M  37/00 516 \	4	4	4C267	A61M  37/00	72	ޥˡɥ¦̤ήϩͭ	flow channel on side of micro-needle
A61M  37/00 520 \	3	3	4C267	A61M  37/00	287	ɽ̤ޤ򥳡ƥ󥰤	medicine coating on surface
A61M  37/00 530 \	3	3	4C267	A61M  37/00	442	ޥˡɥޤ	knead medicine into micro-needle
A61M  37/00 550 \	1	1	4C267	A61M  37/00	548		device for implantation medication
A61M  37/00 560 \	2	2	4C267	A61M  37/00	335	ޤ¢ɲä뤿ΥݡȤ	eqopped with port to add medicine to medicine storage tank
A61M  37/00 590 \	1	1	4C267	A61M  37/00	238	ڥåȤि֡㡥ޡ	device to embed pellet, e.g. marker, solid drug
A61M  39/00  \	0	0	4C066	A61M  39/00	55	ѤäŬɡ³񡤴ɷѤꡤۡ³ޤΤΡʸƵѡ㡥ƻɣͣ͹¡ۣƣˡΣ	Tubes, tube connectors, tube couplings, valves, access sites or the like, specially adapted for medical use (for respiratory devices, e.g. tracheal tubes, A61M 16/00; artificial heart valves A61F  2/24)
A61M  39/02  \	1	1	4C066	A61M  39/02	98	³Σ	Access sites
A61M  39/02 100 \	2	2	4C066	A61M  39/02	211	ΤϽ뤿鲼ΥȡѶͣ	subcutaneous access site for injecting or removing liquid (injecting tool for embedding A61M5/142, 524)
A61M  39/02 102 \	3	3	4C066	A61M  39/02	66	Ŭڤμ¤ˤ뤿֤֤뤿μʤͭΡ㡤С͵Ʃޡ	having means to arrange embedding device to ensure adequate injection, e.g. radiation emission, protuberance, radiopaque marker
A61M  39/02 110 \	2	2	4C066	A61M  39/02	135	ȾʵŪޤϱʵŪʿؤηŪȡʢƩϥơƥͣ͹֣ƣߤαܥ塼֣ʣڡ	semi-permanent or permanent percutaneous access site into human body (peritoneal dialysis catheter A61M1/28; artificial colostomy device A61F5/445; nutrient tube to stomach A61J15/00Z)
A61M  39/02 112 \	3	3	4C066	A61M  39/02	130	ΤФݡȤꤹ뤿μʡ㤷ϥݡȤؤߤΤ̤ʷ㤷κǷƤ	means to fix port on body, or port composed of special shape or specific materials to be embedded into body
A61M  39/02 114 \	3	3	4C066	A61M  39/02	130	ۡ㤷ϳɤͭ	having specific valve, seal or  partition wall
A61M  39/04  \	2	2	4C066	A61M  39/04	284	ɤ̤뼫ʥͭΡΣ	having pierceable self-sealing members
A61M  39/04 100 \	3	3	4C066	A61M  39/04	252	Ԥʤˤäƴ̤褦ͽ᥹åȤΤ	having slit to allow non-sharp tool to pierce
A61M  39/06  \	2	2	4C066	A61M  39/06	105	߷ۡʤˡơƥޤΤΤμϤ򥷡뤹륬åȡΰưߤΡΣ	Haemostasis valves, i.e. gaskets sealing around a needle, catheter or the like, closing on removal thereof
A61M  39/06 100 \	3	3	4C066	A61M  39/06	93	볫䰵ϤĴʤ	having means to adjust opening of seal or pressure
A61M  39/06 110 \	3	3	4C066	A61M  39/06	396	ơƥȤȤѤ	used with catheter
A61M  39/06 120 \	3	3	4C066	A61M  39/06	145	⤷ϤʤǤǤƤư	passice seal made of elastic material and does or does not have opening
A61M  39/06 122 \	4	4	4C066	A61M  39/06	314	å	slit valve
A61M  39/06 130 \	3	3	4C066	A61M  39/06	43	ʾΥޤ	including more than one seal
A61M  39/08  \	1	1	4C066	A61M  39/08	197	ɡΤäŬǼʡΣ	Tubes; Storage means specially adapted therefor
A61M  39/10  \	1	1	4C066	A61M  39/10	628	³ޤϴɷѤΣ	Tube connectors or tube couplings
A61M  39/10 100 \	2	2	4C066	A61M  39/10	703	Ϣݾڤ뤿Υåʡɲäɻ߼ʡʣͣͥ	means of lock to warrant connection; additional means to prevent fraudulent operation (A61M39/16 takes precedence)
A61M  39/10 110 \	2	2	4C066	A61M  39/10	373	®פΥͥ	rapid type connector
A61M  39/10 120 \	2	2	4C066	A61M  39/10	747	٥ʥåȥͥ㡤ͥեͥХͥåȥͥ	swivel nut connector, e.g. connector with screw, bayonet connector
A61M  39/10 130 \	2	2	4C066	A61M  39/10	143	ޥͥ륳ͥޤϥåץ󥰡㡥ޥ롼塼֤Ϣ뤹	multi channel connector or coupling, e.g. connecting multi lumen tube
A61M  39/12  \	2	2	4C066	A61M  39/12	292	Ϣ˽ɤܹ礹뤿ΤΡΣ	for joining a flexible tube to a rigid attachment
A61M  39/14  \	2	2	4C066	A61M  39/14	48	üͭɤ³뤿ΤΡΣ	for connecting tubes having sealed ends
A61M  39/14 100 \	3	3	4C066	A61M  39/14	105	ǵڤܤˤ	by severing or welding
A61M  39/16  \	2	2	4C066	A61M  39/16	220	Ǥޤ̵ͭΡΣ	having provision for disinfection or sterilisation
A61M  39/18  \	3	3	4C066	A61M  39/18	248	̵ݾ֤³ˡޤ֡ʤ̵ݷΣ	Methods or apparatus for making the connection under sterile conditions, i.e. sterile docking
A61M  39/20  \	1	1	4C066	A61M  39/20	470	³ޤϴɤγüѤĺåפޤϥץ饰Σ	Closure caps or plugs for connectors or open ends of tubes
A61M  39/22  \	1	1	4C066	A61M  39/22	320	ۤޤ֡Σ	Valves or arrangement of valves
A61M  39/22 100 \	2	2	4C066	A61M  39/22	531	¿	multgi directional valve
A61M  39/24  \	2	2	4C066	A61M  39/24	687	åХ֤ޤϵջۡΣ	Check- or non-return valves
A61M  39/24 100 \	3	3	4C066	A61M  39/24	298	ͽꤵ줿Ϥή̤ãȤ˳褦߷פ줿Ρ㡥ήΤˤưջ	designed to open when volume of pressure or flow reached target volume established in advance, e.g. fluid driven clack valve
A61M  39/26  \	2	2	4C066	A61M  39/26	870	ɤ³ǤĤȼưŪĤ³ȼưŪ˳ۡΣ	Valves closing automatically on disconnecting the line and opening on reconnection thereof
A61M  39/28  \	2	2	4C066	A61M  39/28	238	ɤʤ뤿㡥顼סΣ	Clamping means for squeezing flexible tubes, e.g. roller clamps
A61M  39/28 100 \	3	3	4C066	A61M  39/28	95	ư塼ּ֡㡥θл˥塼֤ʤ	automatic tube shut off device, e.g. squeezing tube when detecting air
A61M  39/28 110 \	3	3	4C066	A61M  39/28	186	С	lever clamp
A61M  39/28 120 \	3	3	4C066	A61M  39/28	54	९ס㡥п顼	cam clamp, e.g. toller clamp equipped with eccentric shaft
A61M  39/28 130 \	3	3	4C066	A61M  39/28	133	åס㡥Хɤ顼	wedge clamo, e.g. roller clamp equipped with inclined guide
A61M  60/00  \	0	0	4C077	A61M  60/00	19	եݥס۴Ĥ򵡳Ū˺ư뤿֡۴ΤΥХ롼ݥסʿ¡ɷȣŵˡΤο¡ɷ֣ΣˡΣ	Blood pumps; Devices for mechanical circulatory actuation; Balloon pumps for circulatory assistance (heart stimulation A61H 31/00; heart stimulators for electrotherapy A61N 1/362) [2021.01]
A61M  60/10  \	1	1	4C077	A61M  60/10	20	ԤοΤФ뤽ΰ֡Σ	Location thereof with respect to the patient's body [2021.01]
A61M  60/104  \	2	2	4C077	A61M  60/104	113	γݥסʤդԤοΤγǥݥפΡΣ	Extracorporeal pumps, i.e. the blood being pumped outside the patient's body [2021.01]
A61M  60/109  \	3	3	4C077	A61M  60/109	166	γղϩޤϥƥȤ߹ޤ줿ΡΣ	incorporated within extracorporeal blood circuits or systems [2021.01]
A61M  60/113  \	4	4	4C077	A61M  60/113	904	¾εǽ֡㡥Ʃ֤ޤϿ͹֡Ȥ߹ޤ줿ΡΣ	in other functional devices, e.g. dialysers or heart-lung machines [2021.01]
A61M  60/117  \	3	3	4C077	A61M  60/117	294	¡뤿ΤΡ㡥Ūޤγ͹¡Σ	for assisting the heart, e.g. transcutaneous or external ventricular assist devices [2021.01]
A61M  60/122  \	2	2	4C077	A61M  60/122	225	ݥפޤϥݥ֡ʤդԤǥݥפΡΣ	Implantable pumps or pumping devices, i.e. the blood being pumped inside the patient's body [2021.01]
A61M  60/126  \	3	3	4C077	A61M  60/126	53	ɤФơɤظäơɤˡɤľˡɤʬ줹褦ˡޤϷɤμϤ˿ळȤǤΡΣ	implantable via, into, inside, in line, branching on, or around a blood vessel [2021.01]
A61M  60/13  \	4	4	4C077	A61M  60/13	184	ŦФǽˤ륫ơƥˤ꿢ळȤǤΡ㡥ɷϤФưŪƳ줿ơƥݥסΣ	by means of a catheter allowing explantation, e.g. catheter pumps temporarily introduced via the vascular system [2021.01]
A61M  60/135  \	4	4	4C077	A61M  60/135	102	ɤ˿ळȤǤΡ㡥եȽѤѤΡΣ	inside a blood vessel, e.g. using grafting [2021.01]
A61M  60/139  \	5	5	4C077	A61M  60/139	428	ư̮˿ळȤǤΡ㡥ư̮Х롼ݥסΣ	inside the aorta, e.g. intra-aortic balloon pumps [2021.01]
A61M  60/143  \	5	5	4C077	A61M  60/143	4	̮ƶ˿ळȤǤΡ㡥Ϥˤ椵촧̮ƶַŪĺɤ뤿ΤΡΣ	inside the coronary sinus, e.g. for pressure-controlled intermittent coronary sinus occlusion [2021.01]
A61M  60/148  \	4	4	4C077	A61M  60/148	63	ڽѤޤεѤѤƷɤľ˿ळȤǤΡ㡥ɤ˱ʵŪ˿࿴¡֡Σ	in line with a blood vessel using resection or like techniques, e.g. permanent endovascular heart assist devices [2021.01]
A61M  60/152  \	4	4	4C077	A61M  60/152	33	ɤʬ줹褦˿ळȤǤդɤФΡΣ	branching on and drawing blood from a blood vessel [2021.01]
A61M  60/157  \	4	4	4C077	A61M  60/157	5	Ԥηɹ¤˵Ū˺ѤΡ㡥֤̹¤Σ	mechanically acting upon the inside of the patient's blood vessel structure, e.g. contractile structures placed inside a vessel [2021.01]
A61M  60/161  \	4	4	4C077	A61M  60/161	18	Ԥηɹ¤γ˵Ū˺ѤΡ㡥ɤμϤ֤밵¤Σ	mechanically acting upon the outside of the patient's blood vessel structure, e.g. compressive structures placed around a vessel [2021.01]
A61M  60/165  \	3	3	4C077	A61M  60/165	160	¡ˡ¡ξˡޤϿ¡μϤ˿ळȤǤΡΣ	implantable in, on, or around the heart [2021.01]
A61M  60/17  \	4	4	4C077	A61M  60/17	77	˿ळȤǤΡ㡥Х롼ݥסΣ	inside a ventricle, e.g. intraventricular balloon pumps [2021.01]
A61M  60/174  \	5	5	4C077	A61M  60/174	278	ޤư̮Ϥˤ륫˥塼Фƿޤư̮Ϥ˷դǽФΡΣ	discharging the blood to the ventricle or arterial system via a cannula internal to the ventricle or arterial system [2021.01]
A61M  60/178  \	4	4	4C077	A61M  60/178	351	դФγˤ륫˥塼Фư̮Ϥ˷դ᤹Ρ㡥ޤϱ͹¡Σ	drawing blood from a ventricle and returning the blood to the arterial system via a cannula external to the ventricle, e.g. left or right ventricular assist devices [2021.01]
A61M  60/183  \	5	5	4C077	A61M  60/183	31	ξդФΡ㡥ξ͹¡Σ£֣ġϡΣ	drawing blood from both ventricles, e.g. bi-ventricular assist devices [BiVAD] [2021.01]
A61M  60/187  \	4	4	4C077	A61M  60/187	6	ο¡˵Ū˺ѤΡ㡥¡֤̹¤Σ	mechanically acting upon the inside of the patient's native heart, e.g. contractile structures placed inside the heart [2021.01]
A61M  60/191  \	4	4	4C077	A61M  60/191	75	ο¡γ˵Ū˺ѤΡ㡥¡μϤ֤밵¤Σ	mechanically acting upon the outside of the patient's native heart, e.g. compressive structures placed around the heart [2021.01]
A61M  60/196  \	3	3	4C077	A61M  60/196	67	¡ΤִΡ㡥ִ͹¡ΣԣȡϡΣ	replacing the entire heart, e.g. total artificial hearts [TAH] [2021.01]
A61M  60/20  \	1	1	4C077	A61M  60/20	28	μΣ	Type thereof [2021.01]
A61M  60/205  \	2	2	4C077	A61M  60/205	49	ѷեݥסΣ	Non-positive displacement blood pumps [2021.01]
A61M  60/211  \	3	3	4C077	A61M  60/211	3	դݥפ뤿˥åȸ̡٥̤ޤϥȥ쥤ȸ̤ѤΡΣ	using a jet, venturi or entrainment effect for pumping the blood [2021.01]
A61M  60/216  \	3	3	4C077	A61M  60/216	228	դ˺Ѥžࡤ㡥ڥ顤ޤΡΣ	including a rotating member acting on the blood, e.g. impeller [2021.01]
A61M  60/221  \	4	4	4C077	A61M  60/221	82	դȾʬӼʬξͭž̤ήΡ㡥ήݥסΣ	the blood flow through the rotating member having both radial and axial components, e.g. mixed flow pumps [2021.01]
A61M  60/226  \	4	4	4C077	A61M  60/226	14	դȾʬͭž̤ήΡΣ	the blood flow through the rotating member having mainly radial components [2021.01]
A61M  60/232  \	5	5	4C077	A61M  60/232	610	󿴥ݥסΣ	Centrifugal pumps [2021.01]
A61M  60/237  \	4	4	4C077	A61M  60/237	494	դ˼ʬͭž̤ήΡ㡥ήݥסΣ	the blood flow through the rotating member having mainly axial components, e.g. axial flow pumps [2021.01]
A61M  60/242  \	5	5	4C077	A61M  60/242	75	иžФƼ¼Ū˿ľǤΡΣ	with the outlet substantially perpendicular to the axis of rotation [2021.01]
A61M  60/247  \	2	2	4C077	A61M  60/247	39	ѷեݥסΣ	Positive displacement blood pumps [2021.01]
A61M  60/253  \	3	3	4C077	A61M  60/253	141	դľܺѤѰޤΡΣ	including a displacement member directly acting on the blood [2021.01]
A61M  60/258  \	4	4	4C077	A61M  60/258	101	ԥȥݥסΣ	Piston pumps [2021.01]
A61M  60/263  \	5	5	4C077	A61M  60/263	1	Υϥ󥰤ͭΡ㡥ݥסΣ	having a spherical housing, e.g. cardan pumps [2021.01]
A61M  60/268  \	4	4	4C077	A61M  60/268	471	ѰबǤΡ㡥졤եޤϥ֥Σ	the displacement member being flexible, e.g. membranes, diaphragms or bladders [2021.01]
A61M  60/274  \	5	5	4C077	A61M  60/274	29	ȽиƱǤΡ㡥˵ư̮󥿡ѥ륻եݥסΣ	the inlet and outlet being the same, e.g. para-aortic counter-pulsation blood pumps [2021.01]
A61M  60/279  \	5	5	4C077	A61M  60/279	579	ưݥס㡥顼ݥסΣ	Peristaltic pumps, e.g. roller pumps [2021.01]
A61M  60/284  \	6	6	4C077	A61M  60/284	35	˥ưݥסΣ	Linear peristaltic pumps [2021.01]
A61M  60/289  \	2	2	4C077	A61M  60/289	94	۴Ĥ򵡳Ū˺ư뤿֤Ǥäơο¡ޤϷɹ¤˵Ū˺Ѥ뤳ȤˤĤ줿¡εǽΡ㡥ľܿ¡ΣģãáϡΣ	Devices for mechanical circulatory actuation assisting the residual heart function by means mechanically acting upon the patient's native heart or blood vessel structure, e.g. direct cardiac compression [DCC] devices [2021.01]
A61M  60/295  \	2	2	4C077	A61M  60/295	373	۴ΤΥХ롼ݥסΣ	Balloon pumps for circulatory assistance [2021.01]
A61M  60/30  \	1	1	4C077	A61M  60/30	15	̤ðʳΡΰžŪΣ	Medical purposes thereof other than the enhancement of the cardiac output [2021.01]
A61M  60/31  \	2	2	4C077	A61M  60/31	35	¡ή㡥չήä뤿ΤΡΣ	for enhancement of in vivo organ perfusion, e.g. retroperfusion [2021.01]
A61M  60/32  \	3	3	4C077	A61M  60/32	86	ȿήä뤿ΤΡ㡥̮ƶĺɤѤΡΣ	of heart muscle tissues, e.g. using coronary sinus occlusion [2021.01]
A61M  60/33  \	3	3	4C077	A61M  60/33	20	¡ήä뤿ΤΡΣ	of kidneys [2021.01]
A61M  60/34  \	2	2	4C077	A61M  60/34	12	ͻ衤㡥­ؤν۴Ĥä뤿ΤΡΣ	for enhancement of circulation to the extremities, e.g. the feet [2021.01]
A61M  60/35  \	2	2	4C077	A61M  60/35	18	γŪ֤ΤΤΡ㡥ե󥿥ѤΤΤΡΣ	for specific surgeries, e.g. for Fontan procedure [2021.01]
A61M  60/36  \	2	2	4C077	A61M  60/36	105	ηսΤΤΡμŤΤΤΡΣ	for specific blood treatment; for specific therapy [2021.01]
A61M  60/37  \	3	3	4C077	A61M  60/37	402	ƩϡɲޤƩɲΣ	Haemodialysis, haemofiltration or diafiltration [2021.01]
A61M  60/38  \	3	3	4C077	A61M  60/38	430	ջǲΣ	Blood oxygenation [2021.01]
A61M  60/39  \	2	2	4C077	A61M  60/39	276	͢ΤΤΡΣ	for blood transfusion [2021.01]
A61M  60/40  \	1	1	4C077	A61M  60/40	3	ưȴϢΣ	Details relating to driving [2021.01]
A61M  60/403  \	2	2	4C077	A61M  60/403	16	ѷեݥפΤΤΡΣ	for non-positive displacement blood pumps [2021.01]
A61M  60/405  \	3	3	4C077	A61M  60/405	20	ܿ˺ѤϤհޤϵΰǤΡΣ	the force acting on the blood contacting member being hydraulic or pneumatic [2021.01]
A61M  60/408  \	3	3	4C077	A61M  60/408	23	ܿ˺ѤϤŪϡ㡥եȤޤϥ֥ˤãϡǤΡΣ	the force acting on the blood contacting member being mechanical, e.g. transmitted by a shaft or cable [2021.01]
A61M  60/411  \	4	4	4C077	A61M  60/411	171	Ϥŵ⡼ˤȯΡΣ	generated by an electromotor [2021.01]
A61M  60/414  \	5	5	4C077	A61M  60/414	183	Ϥž֥ˤãΡ㡥ơƥܤեݥסΣ	transmitted by a rotating cable, e.g. for blood pumps mounted on a catheter [2021.01]
A61M  60/416  \	5	5	4C077	A61M  60/416	208	Ϥ⡼ΥζưեȤˤľãΡΣ	transmitted directly by the motor rotor drive shaft [2021.01]
A61M  60/419  \	3	3	4C077	A61M  60/419	338	ܿ˺ѤϤʵ׼ŪǤΡ㡥ưФưФȤδ֤βž礫Σ	the force acting on the blood contacting member being permanent magnetic, e.g. from a rotating magnetic coupling between driving and driven magnets [2021.01]
A61M  60/422  \	3	3	4C077	A61M  60/422	261	ܿ˺ѤϤżŪǤΡ㡥ɥ⡼ݥפѤΡΣ	the force acting on the blood contacting member being electromagnetic, e.g. using canned motor pumps [2021.01]
A61M  60/424  \	2	2	4C077	A61M  60/424	3	ѷեݥפΤΤΡΣ	for positive displacement blood pumps [2021.01]
A61M  60/427  \	3	3	4C077	A61M  60/427	332	ܿ˺ѤϤհޤϵΰǤΡΣ	the force acting on the blood contacting member being hydraulic or pneumatic [2021.01]
A61M  60/43  \	4	4	4C077	A61M  60/43	58	եݥפˤƿѤΡ㡥Ŷ¥ʤ뤿˿ѤΡΣ	using vacuum at the blood pump, e.g. to accelerate filling [2021.01]
A61M  60/432  \	4	4	4C077	A61M  60/432	0	Ϥ뤫˹⤤֤٤ưեݥפߤޤϵž뤳Ȥˤ뿴ĥޤϿ̴ؤȼΡΣ	with diastole or systole switching by stopping or reversing the blood pump operating at a much higher cyclical speed than the heart beat [2021.01]
A61M  60/435  \	4	4	4C077	A61M  60/435	96	եݥפȱհޤϵΰͥ륮Ȥδ֤˰֤ۼʤˤ뿴ĥޤϿ̴ؤȼΡΣ	with diastole or systole switching by valve means located between the blood pump and the hydraulic or pneumatic energy source [2021.01]
A61M  60/438  \	3	3	4C077	A61M  60/438	120	ܿ˺ѤϤŪǤΡΣ	the force acting on the blood contacting member being mechanical [2021.01]
A61M  60/441  \	4	4	4C077	A61M  60/441	168	Ϥŵ⡼ˤȯΡΣ	generated by an electromotor [2021.01]
A61M  60/443  \	5	5	4C077	A61M  60/443	78	žѰ¿ʱưѴʤͭΡΣ	with means converting the rotation into a translational movement of the displacement member [2021.01]
A61M  60/446  \	6	6	4C077	A61M  60/446	15	ž¿ʱưμȤʿԤǤΡ㡥饹奢奨ޤϱư֡Σ	the axis of both movements being parallel, e.g. roller screw actuators or cylindrical cam transmissions [2021.01]
A61M  60/449  \	4	4	4C077	A61M  60/449	20	ϤΥɤˤȯΡΣ	generated by a solenoid [2021.01]
A61M  60/451  \	4	4	4C077	A61M  60/451	0	ϤŵǮ奨㡥⥢奨ˤȯΡΣ	generated by electro-thermomechanical actuators, e.g. shape memory alloy actuators [2021.01]
A61M  60/454  \	4	4	4C077	A61M  60/454	8	Ϥŵ奨ˤȯΡ㡥ŵݥޡޤϰǻҤѤΡΣ	generated by electro-active actuators, e.g. using electro-active polymers or piezo-electric elements [2021.01]
A61M  60/457  \	3	3	4C077	A61M  60/457	1	ܿ˺ѤϤŪǤΡΣ	the force acting on the blood contacting member being magnetic [2021.01]
A61M  60/459  \	4	4	4C077	A61M  60/459	10	Ϥʵ׼ФˤȯΡΣ	generated by permanent magnets [2021.01]
A61M  60/462  \	4	4	4C077	A61M  60/462	18	żϡΣ	Electromagnetic force [2021.01]
A61M  60/465  \	2	2	4C077	A61M  60/465	1	۴Ĥ򵡳Ū˺ư뤿֤ΤΤΡΣ	for devices for mechanical circulatory actuation [2021.01]
A61M  60/468  \	3	3	4C077	A61M  60/468	70	ưʤ˺ѤϤհޤϵΰǤΡΣ	the force acting on the actuation means being hydraulic or pneumatic [2021.01]
A61M  60/47  \	3	3	4C077	A61M  60/47	13	ưʤ˺ѤϤŪǤΡ㡥ɤ򥯥פ뵡Ū˶ưΣ	the force acting on the actuation means being mechanical, e.g. mechanically driven members clamping a blood vessel [2021.01]
A61M  60/473  \	4	4	4C077	A61M  60/473	11	Ϥŵ⡼ˤȯΡΣ	generated by an electromotor [2021.01]
A61M  60/476  \	5	5	4C077	A61M  60/476	9	žѰ¿ʱưѴʤͭΡΣ	with means converting the rotation into a translational movement of the displacement member [2021.01]
A61M  60/478  \	6	6	4C077	A61M  60/478	0	ž¿ʱưμȤʿԤǤΡ㡥饹奢奨ޤϱư֡Σ	the axis of both movements being parallel, e.g. roller screw actuators or cylindrical cam transmissions [2021.01]
A61M  60/481  \	4	4	4C077	A61M  60/481	5	ϤΥɤˤȯΡΣ	generated by a solenoid [2021.01]
A61M  60/484  \	4	4	4C077	A61M  60/484	1	ϤŵǮ奨㡥⥢奨ˤȯΡΣ	generated by electro-thermomechanical actuators, e.g. shape memory alloy actuators [2021.01]
A61M  60/486  \	4	4	4C077	A61M  60/486	8	Ϥŵ奨ˤȯΡ㡥ŵݥޡޤϰǻҤѤΡΣ	generated by electro-active actuators, e.g. using electro-active polymers or piezo-electric elements [2021.01]
A61M  60/489  \	3	3	4C077	A61M  60/489	2	ưʤ˺ѤϤŪǤΡΣ	the force acting on the actuation means being magnetic [2021.01]
A61M  60/492  \	4	4	4C077	A61M  60/492	6	Ϥʵ׼ФˤȯΡΣ	generated by permanent magnets [2021.01]
A61M  60/495  \	4	4	4C077	A61M  60/495	7	żϡΣ	Electromagnetic force [2021.01]
A61M  60/497  \	2	2	4C077	A61M  60/497	267	۴ΤΥХ롼ݥסΣ	for balloon pumps for circulatory assistance [2021.01]
A61M  60/50  \	1	1	4C077	A61M  60/50	10	ȴϢΣ	Details relating to control [2021.01]
A61M  60/508  \	2	2	4C077	A61M  60/508	189	Żʡ㡥եɥХåĴΤΤΡΣ	Electronic control means, e.g. for feedback regulation [2021.01]
A61M  60/515  \	3	3	4C077	A61M  60/515	191	ꥢ륿δԥǡѤĴΣ	Regulation using real-time patient data [2021.01]
A61M  60/523  \	4	4	4C077	A61M  60/523	117	ήǡ㡥ήȥ󥹥ǥ塼ΥǡѤΡΣ	using blood flow data, e.g. from blood flow transducers [2021.01]
A61M  60/531  \	4	4	4C077	A61M  60/531	314	찵ǡ㡥찵󥵤ΥǡѤΡΣ	using blood pressure data, e.g. from blood pressure sensors [2021.01]
A61M  60/538  \	3	3	4C077	A61M  60/538	207	ꥢ륿ηեݥѥ᡼Υǡ㡥⡼ήѤĴΣ	Regulation using real-time blood pump operational parameter data, e.g. motor current [2021.01]
A61M  60/546  \	4	4	4C077	A61M  60/546	248	ήĴᡤ㡥®٤Ŭ礵뤳ȤˤΡΣ	of blood flow, e.g. by adapting rotor speed [2021.01]
A61M  60/554  \	4	4	4C077	A61M  60/554	63	찵ĴΣ	of blood pressure [2021.01]
A61M  60/562  \	3	3	4C077	A61M  60/562	59	̮ưήʤեݥηή̮ưˤ뤿ΤΡΣ	for making blood flow pulsatile in blood pumps that do not intrinsically create pulsatile flow [2021.01]
A61M  60/569  \	4	4	4C077	A61M  60/569	153	οƱŪǤΡΣ	synchronous with the native heart beat [2021.01]
A61M  60/577  \	3	3	4C077	A61M  60/577	2	ȶưΣ	High-frequency driving [2021.01]
A61M  60/585  \	2	2	4C077	A61M  60/585	247	桼󥿡եΣ	User interfaces [2021.01]
A61M  60/592  \	2	2	4C077	A61M  60/592	42	Υ줿ˤ륪ڥ졼ؤδԥǡޤϷեݥץǡνŪãΣ	Communication of patient or blood pump data to distant operators for treatment purposes [2021.01]
A61M  60/80  \	1	1	4C077	A61M  60/80	1	ưȴϢʳι¤κΣ	Constructional details other than related to driving [2021.01]
A61M  60/802  \	2	2	4C077	A61M  60/802	13	ѷեݥפΤΡΣ	of non-positive displacement blood pumps [2021.01]
A61M  60/804  \	3	3	4C077	A61M  60/804	267	ڥΣ	Impellers [2021.01]
A61M  60/806  \	4	4	4C077	A61M  60/806	259	١ޤϥ֥졼ɡΣ	Vanes or blades [2021.01]
A61M  60/808  \	5	5	4C077	A61M  60/808	100	ѷǽʥڥ顤㡥ĥǽʥڥ顤äŬΡΣ	specially adapted for deformable impellers, e.g. expandable impellers [2021.01]
A61M  60/81  \	3	3	4C077	A61M  60/81	264	ݥץϥ󥰡Σ	Pump housings [2021.01]
A61M  60/812  \	4	4	4C077	A61M  60/812	64	١ޤϥ֥졼ɡ㡥ꤵ줿ή쥬ɡΣ	Vanes or blades, e.g. static flow guides [2021.01]
A61M  60/814  \	4	4	4C077	A61M  60/814	46	ܥ塼ȡΣ	Volutes [2021.01]
A61M  60/816  \	4	4	4C077	A61M  60/816	101	ϥ󥰤ξޤ֤줿󥵡㡥Ķή쥻󥵡Σ	Sensors arranged on or in the housing, e.g. ultrasonic flow sensors[2021.01]
A61M  60/818  \	3	3	4C077	A61M  60/818	37	Σ	Bearings [2021.01]
A61M  60/82  \	4	4	4C077	A61M  60/82	168	Σ	Magnetic bearings [2021.01]
A61M  60/822  \	5	5	4C077	A61M  60/822	51	ƥ椵ΤäŬΡΣ	specially adapted for being actively controlled [2021.01]
A61M  60/824  \	4	4	4C077	A61M  60/824	200	ưޤή켴Σ	Hydrodynamic or fluid film bearings [2021.01]
A61M  60/825  \	4	4	4C077	A61M  60/825	220	ܿ㡥̼ޤϥԥܥåȼΣ	Contact bearings, e.g. ball-and-cup or pivot bearings [2021.01]
A61M  60/827  \	3	3	4C077	A61M  60/827	55	ưʴ֤Υ󥰡Σ	Sealings between moving parts [2021.01]
A61M  60/829  \	4	4	4C077	A61M  60/829	83	ѡնʤͭΡΣ	having a purge fluid supply [2021.01]
A61M  60/831  \	5	5	4C077	A61M  60/831	5	ɲᤵ줿դѡդȤѤΡΣ	using filtered blood as purge fluid [2021.01]
A61M  60/833  \	3	3	4C077	A61M  60/833	9	ήɻߤ뤿ĺΣ	Occluders for preventing backflow [2021.01]
A61M  60/835  \	2	2	4C077	A61M  60/835	145	ѷեݥפΤΡΣ	of positive displacement blood pumps [2021.01]
A61M  60/837  \	3	3	4C077	A61M  60/837	238	Ѱ˴ؤ㡥ޤϺΣ	Aspects of flexible displacement members, e.g. shapes or materials [2021.01]
A61M  60/839  \	2	2	4C077	A61M  60/839	46	۴Ĥ򵡳Ū˺ư뤿֤ΤΡΣ	of devices for mechanical circulatory actuation [2021.01]
A61M  60/841  \	2	2	4C077	A61M  60/841	83	۴ΤΥХ롼ݥפΤΡΣ	of balloon pumps for circulatory assistance [2021.01]
A61M  60/843  \	3	3	4C077	A61M  60/843	164	Х롼˴ؤ㡥ޤϺΣ	Balloon aspects, e.g. shapes or materials [2021.01]
A61M  60/845  \	2	2	4C077	A61M  60/845	163	γեݥפΤΡΣ	of extracorporeal blood pumps [2021.01]
A61M  60/847  \	3	3	4C077	A61M  60/847	96	åȤ֤줿ΡΣ	arranged in a cassette [2021.01]
A61M  60/849  \	3	3	4C077	A61M  60/849	100	ȤΤƤʡΣ	Disposable parts [2021.01]
A61M  60/851  \	3	3	4C077	A61M  60/851	221	ۡΣ	Valves [2021.01]
A61M  60/853  \	4	4	4C077	A61M  60/853	42	ۤή¤뤿˥פʥ塼ǤˤΡΣ	the valve being formed by a flexible tube element which is clamped for restricting the flow [2021.01]
A61M  60/855  \	2	2	4C077	A61M  60/855	36	ݥפޤϥݥ֤ΤΡΣ	of implantable pumps or pumping devices [2021.01]
A61M  60/857  \	3	3	4C077	A61M  60/857	170	ե塼֡Σ	Implantable blood tubes [2021.01]
A61M  60/859  \	4	4	4C077	A61M  60/859	52	ΤϢΣ	Connections therefor [2021.01]
A61M  60/861  \	3	3	4C077	A61M  60/861	97	ݥפޤϥݥ֤򴵼ԤοΤʬϢޤϸꤹ뤿ϢޤϸΣ	Connections or anchorings for connecting or anchoring pumps or pumping devices to parts of the patient's body [2021.01]
A61M  60/863  \	4	4	4C077	A61M  60/863	12	󥰡Σ	Apex rings [2021.01]
A61M  60/865  \	3	3	4C077	A61M  60/865	142	ݥפޤϥݥ֤򴵼Ԥ˰ޤ뤿֡Σ	Devices for guiding or inserting pumps or pumping devices into the patient's body [2021.01]
A61M  60/867  \	4	4	4C077	A61M  60/867	32	ΰָФѤΡ㡥ơƥܤ졤ơƥ̤ƶưեݥפΤΤΡΣ	using position detection during deployment, e.g. for blood pumps mounted on and driven through a catheter [2021.01]
A61M  60/869  \	3	3	4C077	A61M  60/869	12	եФư뤿εΤޤϷհʳαΤޤСΣ	Compliance chambers containing a gas or liquid other than blood to compensate volume variations of a blood chamber [2021.01]
A61M  60/871  \	3	3	4C077	A61M  60/871	26	ͥ륮֡ΤѴΣ	Energy supply devices; Converters therefor [2021.01]
A61M  60/873  \	4	4	4C077	A61M  60/873	81	̵ͥ륮ޤϷŪͥ륮ΣԣţԡϤäŬΡ㡥żͶƳšΣ	specially adapted for wireless or transcutaneous energy transfer [TET], e.g. inductive charging [2021.01]
A61M  60/875  \	5	5	4C077	A61M  60/875	29	γ뤪ӿ֤ŬΤäŬΡΣ	specially adapted for optimising alignment of external and implantable coils [2021.01]
A61M  60/876  \	4	4	4C077	A61M  60/876	78	ӡΣ	Implantable batteries [2021.01]
A61M  60/878  \	4	4	4C077	A61M  60/878	39	ԤοˤŵŪ³Σ	Electrical connections within the patient's body [2021.01]
A61M  60/88  \	4	4	4C077	A61M  60/88	112	Ū֥Σ	Percutaneous cables [2021.01]
A61M  60/882  \	4	4	4C077	A61M  60/882	5	Ԥˤư϶뤵֡㡥ʶڤˤư϶뤵֡Σ	Devices powered by the patient, e.g. skeletal muscle powered devices [2021.01]
A61M  60/884  \	3	3	4C077	A61M  60/884	0	ɲŪʿս֤ȴϢΡΣ	being associated to additional implantable blood treating devices [2021.01]
A61M  60/886  \	4	4	4C077	A61M  60/886	4	ջǲ֡Σ	Blood oxygenators [2021.01]
A61M  60/888  \	4	4	4C077	A61M  60/888	9	եե륿Σ	Blood filters [2021.01]
A61M  60/89  \	3	3	4C077	A61M  60/89	8	ۡΣ	Valves [2021.01]
A61M  60/892  \	4	4	4C077	A61M  60/892	53	ǽưۡʤϤˤưΡΣ	Active valves, i.e. actuated by an external force [2021.01]
A61M  60/894  \	4	4	4C077	A61M  60/894	103	ưۡʤդˤưΡΣ	Passive valves, i.e. valves actuated by the blood [2021.01]
A61M  60/896  \	5	5	4C077	A61M  60/896	19	ʡޤϤΤʡ㡥եåۡͭΡΣ	having flexible or resilient parts, e.g. flap valves [2021.01]
A61M  60/898  \	4	4	4C077	A61M  60/898	1	եݥפݥפǤäơ줬ۤȤƺѤΡΣ	the blood pump being a membrane blood pump and the membrane acting as inlet valve [2021.01]
A61M  60/90  \	1	1	4C077	A61M  60/90	39	롼ףͣͣޤϣͣޤʤΣ	Details not provided for in groups A61M 60/40, A61M 60/50 or A61M 60/80 [2021.01]
A61M  99/00  \	0	0	4C267	A61M  99/00	2	Υ֥饹¾Υ롼פʬवʤΣ	Subject matter not provided for in other groups of this subclass [2012.01]
