F24F   1/00  \	0	0	3L049	F24F   1/00	1642	Ĵ¤ΤΥ롼˥åȡ㡥ʬΥޤϼǼΤΤ뤤֤飱ΡΣ	Room units, e.g. separate or self-contained units or units receiving primary air from a central station [1,2011.01]
F24F   1/0003  \	1	1	3L049	F24F   1/0003	686	Ĵ¥ƥιǡ㡥ȯȶŽ̴줾̡Υ˥åȤ˼ƤƤʬΥΤΡΣ	characterised by a split arrangement, wherein parts of the air-conditioning system, e.g. evaporator and condenser, are in separately located units
F24F   1/0007  \	1	1	3L049	F24F   1/0007	715	˥åȡ㡥ե󥳥˥åȡʼǼ˥åȣƣƣˡΣ	Indoor units, e.g. fan coil units (self-contained units F24F 1/02)
F24F   1/0007 321 \	2	2	3L050	F24F   1/0007	1471	Ω˴ؤΡ㡥ưե󡤥ե󥱡󥰤μ֤˴ؤΡǮ򴹴ƣƣϪƣƣġƣƣȡ	related to assembly, e.g. motors, fans, related to mounting arrangement of fan casing (heat exchangers F24 F1/0063; drain pan F24F1/0007, 361D, F24F1/0007, 361H)
F24F   1/0007 331 \	2	2	3L050	F24F   1/0007	1791	䲹ѤΡ㡥ޤϲѤ˼Ρʮ̸إХ֤ޤ϶ȴ	using of cold or hot water, e.g. using cold water or hot water for cooling and heating, atomizers, selector valves or air purging valves
F24F   1/0007 361 \	2	2	3L050	F24F  13/22	20	Ž̿ɻߵڤӶŽ̿νȼϪ	Preventing generation of condensate, and removing and collecting condensed watercondensate; drain pan
F24F   1/0007 361 A	2	0	3L050	F24F  13/22	566	ϪɻߡǮĤѤȢΣƣƣġǮѤϪƣƣȡ	Preventing condensation (housing using insulation panel F24F 1/0007, 401D; drain pan using insulating materials F24F 1/0007, 361H)
F24F   1/0007 361 B	2	0	3L050	F24F  13/22	1878	Ž̿ӿ㡥ӿ塤ƳɡϪƳϪĤޤϾȯ	Wastewater treatment for condensation water (of condensate), e.g. natural drainage, water pipes, auxiliary drip trays, guiding plates or vaporizers
F24F   1/0007 361 F	2	1	3L050	F24F  13/22	877	Ž̿ζӿ㡥ӿݥסҡޤॵιⰵɤˤ	Forced drainage of condensate, e.g. by discharge pump, heater or high pressure pipe of refrigeration cycle
F24F   1/0007 361 C	2	0	3L050	F24F  13/22	502	Ž̿ѤΡ㡥üޤ϶Ž̴ؤλ	using condensate, e.g. spraying to humidifiers or condensers
F24F   1/0007 361 D	2	0	3L050	F24F  13/22	1556	Ϫ㡥ȥ졼ʡϪƣƣ¡	Drain pan , e.g. strainers (auxiliary drip trays F24F 1/0007, 361B)
F24F   1/0007 361 H	2	1	3L050	F24F  13/22	199	ǮѤϪ	Drain pan using insulating materials
F24F   1/0007 361 Z	2	0	3L050	F24F  13/22	355	¾㡥Ϫɻ	Others, e.g. preventing drips from flying
F24F   1/0007 381 \	2	2	3L051	F24F   1/0007	784	۴Ķεӵڴ㡥иڤӵ۹ѡˤڴ	Switching supply/exhaust of circulating air, e.g. switching inlets and outlets by dampers, air blowers or the like
F24F   1/0007 401 \	2	2	3L051	F24F  13/20	24	Ȣ	Housing
F24F   1/0007 401 A	2	0	3L051	F24F  13/20	1132	ȢΤΩƤħΡ㡥ӥͥåȤޤη̥ѥͥμգƣƣ¡	Characterised by housing assembly, e.g. connection of cabinets or base plates and the likes (mounting of front panels F24F 1/0007, 401B)
F24F   1/0007 401 B	2	0	3L051	F24F  13/20	2063	̥ѥͥ˴ؤΡ㡥ġѥѥͥ롤Ȥޤġ̥μգƣƣáƣƣڡ	related to front panels, e.g. decorative laminates, decorative panels, decorative frames or front panels (mounting of front panels F24F 1/0007, 401C; inspection lids, inspection holes F24F 1/0007, 401Z)
F24F   1/0007 401 C	2	0	3L051	F24F  13/20	3543	̥˴ؤΡ㡥롼Сޤġʶήƣƣ	related to front grills, e.g. louvers, doors or wind direction plates (airflow controlling materials F24F 13/08)
F24F   1/0007 401 D	2	0	3L051	F24F  13/20	2358	μդޤ֤˴ؤΡ㡥֡ļꡤӡɲġݸСޤǮ	related to mounting or arrangment of auxiliary members, e.g. arrangement, handles, legs, accoustic insulation boards, protective covers or heat insulation boards
F24F   1/0007 401 E	2	0	3L051	F24F  13/20	2144	ŵʤμդޤ֤˴ؤΡ㡥ŵȢŵɤޤϥ⥳󥹥å֣ƣƣåƣƣڡ	related to mounting or arrangement of electric components, e.g. electrical components box, electric cord or remote-control switches (control device F24F 11/00; switching door F24F 1/0007, 401Z)
F24F   1/0007 401 Z	2	0	3L051	F24F  13/20	513	¾㡥ޤϥå	Others, e.g. inspection door or switch door
F24F   1/0011  \	2	2	3L049	F24F   1/0011	582	иħΤΡΣ	characterised by air outlets
F24F   1/0014  \	3	3	3L049	F24F   1/0014	1239	İʾοиͭΡΣ	having two or more outlet openings
F24F   1/0018  \	2	2	3L049	F24F   1/0018	1294	եħΤΡʣʮͺѤˤͶΣƣƣˡΣ	characterised by fans(with secondary air induced by injector action of the primary air F24F1/01)
F24F   1/0022  \	3	3	3L049	F24F   1/0022	2267	󿴼եޤϥ饸եΣ	Centrifugal or radial fans
F24F   1/0025  \	3	3	3L049	F24F   1/0025	1463	եեδήեϤޤϲήեΣ	Cross-flow or tangential fans
F24F   1/0029  \	3	3	3L049	F24F   1/0029	543	ήեΣ	Axial fans
F24F   1/0033  \	3	3	3L049	F24F   1/0033	688	İʾΥեͭΡΣ	having two or more fans
F24F   1/0035  \	2	2	3L052	F24F   1/0035	604	ؤγƳħΤΡΣ	characterised by introduction of outside air to the room
F24F   1/0038  \	3	3	3L052	F24F   1/0038	365	Ʊ˹ԤⵤӽФȤ߹碌ΡΣ	
F24F   1/0038 441 \	4	4	3L052	F24F   1/0038	447	ͥ륮֤ĤΡ㡥Ǯ򴹴ͭΡʽ£ģ	with energy recovery device, e.g. with Total Heat Exchanger (dehumidifier B01D 53/00)
F24F   1/0041  \	2	2	3L052	F24F   1/0041	402	ⵤӽФħΤΡƱ˹ԤƳȤ߹碌ΣƣƣˡΣ	characterised by exhaustion of inside air from the room(in combination with simultaneous introduction of outside air F24F1/0038)
F24F   1/0043  \	2	2	3L052	F24F   1/0043	326	դ֤ħΤΡΣ	
F24F   1/0043 416 \	3	3	3L052	F24F   1/0043	282	ɤޤɴ̼ɥѥͥƣƣ	Window or wall penetration type (wall panel embedded type F24F 1/0057)
F24F   1/0047  \	3	3	3L052	F24F   1/0047	1932	ŷޤŷ˼դΡΣ	mounted in the ceiling or at the ceiling
F24F   1/005  \	3	3	3L052	F24F   1/005	296	˼դΡΩƤΡΣ	mounted on the floor; standing on the floor
F24F   1/0053  \	3	3	3L052	F24F   1/0053	110	ʤȤʬŪ˾˼դΡʬ۴ͭΡΣ	mounted at least partially below the floor; with air distribution below the floor
F24F   1/0057  \	3	3	3L052	F24F   1/0057	1096	ɤޤɤ˼դΡΣ	mounted in or on a wall
F24F   1/0059  \	2	2	3L051	F24F   1/0059	449	Ǯ򴹴ħΤΡΣ	characterised by heat exchangers
F24F   1/0063  \	3	3	3L051	F24F   1/0063	1535	Ǯ򴹴μդޤ֡Σ	by the mounting or arrangement of the heat exchangers
F24F   1/0067  \	3	3	3L051	F24F   1/0067	1450	Ǯ򴹴ޤϤʡ㡥ե󡤤ηΣ	by the shape of the heat exchangers or of parts thereof, e.g. of their fins
F24F   1/0068  \	2	2	3L051	F24F   1/0068	893	˥åȥˤ롤Ǯ򴹴ﳰ۴ɤ֤ħΤΡΣ	characterised by the arrangement of refrigerant piping outside the heat exchanger within the unit casing
F24F   1/0071  \	2	2	3L051	F24F   1/0071	130	뵤ʡ˧ޤæʣƣƣˡΣ	with means for purifying supplied air(perfuming or deodorising means F24F1/008)
F24F   1/0073  \	3	3	3L051	F24F   1/0073	3826	ե륿μդޤ֤ħΤΡΣ	characterised by the mounting or arrangement of filters
F24F   1/0076  \	3	3	3L051	F24F   1/0076	1551	ŵŪʡ㡥ʥޤʬΥˤΡΣ	by electric means, e.g. ionisers or electrostatic separators
F24F   1/008  \	2	2	3L051	F24F   1/008	1278	˧ޤæʤͭΡΣ	with perfuming or deodorising means
F24F   1/0083  \	2	2	3L052	F24F   1/0083	1000	ʤͭΡΣ	with dehumidification means
F24F   1/0087  \	2	2	3L050	F24F   1/0087	1217	üʤͭΡΣ	with humidification means
F24F   1/009  \	2	2	3L050	F24F   1/009	338	Ǯ֤ħΤΡǮ򴹴ħΤΣƣƣˡΣ	characterised by heating arrangements(characterised by heat exchangers F24F1/0059)
F24F   1/0093  \	3	3	3L050	F24F   1/0093	1076	ɲäռͼǮǤͭΡ㡥ŵҡΣ	with additional radiant heat-discharging elements, e.g. electric heaters
F24F   1/0097  \	3	3	3L050	F24F   1/0097	612	ǮŤޤǮʤѤΡ㡥ڥǻҡΣ	using thermoelectric or thermomagnetic means, e.g. Peltier elements
F24F   1/01  \	1	1	3L052	F24F   1/01	92	ǣʮͺѤˤͶΡΣ	in which secondary air is induced by injector action of the primary air [3,2011.01]
F24F   1/02  \	1	1	3L049	F24F   1/02	954	Ĵ¤ΤμǼ롼˥åȡʤĤζ̤ΥΤ֤ĤΡΣ	Self-contained room units for air-conditioning, i.e. with all apparatus for treatment installed in a common casing [2019.01]
F24F   1/02 371 \	2	2	3L050	F24F  13/22	8	Ž̿ɻߵڤӶŽ̿νȼϪ	Preventing generation of defrost water, and removing and collecting defrost water; drip trays
F24F   1/02 371 A	2	0	3L050	F24F  13/22	153	ϪɻߡǮĤѤȢΣƣƣġǮѤϪƣƣġ	Preventing condensation (housing using of insulating panel F24F 1/02, 411D, drain pan using of insulating material  F24F 1/02, 371D)
F24F   1/02 371 B	2	0	3L050	F24F  13/22	737	Ž̿ӿ㡥ӿ塤ƳɡϪƳϪĤޤϾȯ	Waste water treatment of condensate, e.g. natural drainage, water pipes, auxiliary drain pan , thin drip plates or vaporisation
F24F   1/02 371 F	2	1	3L050	F24F  13/22	248	Ž̿ζӿ㡥ݥסҡޤॵιⰵɤѤ	Forced waste water treatment of condensate, e.g. by pumps, heaters or high pressure pipes of refrigerating cycles
F24F   1/02 371 C	2	1	3L050	F24F  13/22	682	Ž̿ѤΡ㡥üŽ̴ʳȤ	using of condensate, e.g. spraying to humidifiers or other components except condensers
F24F   1/02 371 G	2	1	3L050	F24F  13/22	494	󥬥󥰤ˤΡ㡥žĤˤ	by slinger rings, e.g. spraying by rotating discs
F24F   1/02 371 D	2	0	3L050	F24F  13/22	457	Ϫ	Drip trays
F24F   1/02 371 J	2	1	3L050	F24F  13/22	504	󥯵ڤӤ帡	Tanks and priming detection
F24F   1/02 371 Z	2	0	3L050	F24F  13/22	103	¾㡥Ϫɻ	Others, e.g. preventing drips from flying or entrained into air flow
F24F   1/02 391 \	2	2	3L051	F24F   1/02	190	۴Ķεӵڴ㡥иڤӵ۹ѡޤˤڴ	Switching supply/exhaust of circulating air, e.g. switching inlets and outlets by dampers, air blowers or the like
F24F   1/02 411 \	2	2	3L051	F24F  13/20	15	Ȣ	Housings
F24F   1/02 411 A	2	0	3L051	F24F  13/20	384	ȢΤΩƤħΡ㡥ӥͥåȤޤη̥ѥͥμգƣƣ¡	characterised by assembly of housings, e.g. connection of cabinets, base plates or the like (mounting of front panels F24F 1/02, 411B)
F24F   1/02 411 B	2	0	3L051	F24F  13/20	225	̥ѥͥ˴ؤΡ㡥ġѥѥͥ롤Ȥޤġ̥μգƣƣáƣƣڡ	related to front panels, e.g. decorative laminates, decorative panels, decorative frames or front panels (attachment of front grills F24F 1/02, 411C; inspection doors or inspection holes F24F 1/02, 411Z)
F24F   1/02 411 C	2	0	3L051	F24F  13/20	443	̥˴ؤΡ㡥롼Сޤġʶήƣƣ	related to front grills, e.g. louvers, doors or wind direction plates (air flow-controlling members F 24 F 13/08)
F24F   1/02 411 D	2	0	3L051	F24F  13/20	502	μդޤ֤˴ؤΡ㡥۴ɡļꡤӡɲġݸСޤǮ	related to mounting or arrangement of auxiliary members , e.g. piping, handles, legs, acoustical insulation boards, protection coverings or insulating panels
F24F   1/02 411 E	2	0	3L051	F24F  13/20	437	ŵʤμդޤ֤˴ؤΡ㡥ŵȢŵɤޤϥ⥳󥹥å֣ƣƣåƣƣڡ	related to mounting or arrangement of electric components , e.g. electric component box, electric cords, remote-control switches (control devices F24F 11/02, switch doors F24F 1/02, 411Z)
F24F   1/02 411 Z	2	0	3L051	F24F  13/20	83	¾㡥ޤϥå	Others e.g. inspection doors or switch doors
F24F   1/02 441 \	2	2	3L052	F24F   1/02	7	ؤε뵤ؤӵ	Supplying air to rooms:  exhausting air outdoor
F24F   1/02 441 A	2	0	3L052	F24F   1/02	223	Ƴ	introducing outside air
F24F   1/02 441 B	2	0	3L052	F24F   1/02	221	ⵤӽФ	exhausting internal air
F24F   1/02 441 C	2	0	3L052	F24F   1/02	359	Ʊӵ	supplying and exhausting air simultaneously
F24F   1/02 441 Z	2	0	3L052	F24F   1/02	18	¾	Others
F24F   1/02 446 \	3	3	3L052	F24F   1/02	178	ͥ륮֤ĤΡ㡥Ǯ򴹴Ĥ	having energy recovery devices, e.g. with all-heat exchangers
F24F   1/022  \	2	2	3L049	F24F   1/022	7056	̼ޤΡΣ	comprising a compressor cycle
F24F   1/027  \	3	3	3L052	F24F   1/027	1269	ɤγ㡥롤˼դΡΣ	mounted in wall openings, e.g. in windows
F24F   1/028  \	2	2	3L049	F24F   1/028	926	뵤ʡ㡥ե󥱡󥰡ѤޤϥȡħΤΡʣʮͺѤˤͶΣƣƣˡΣ	characterised by air supply means, e.g. fan casings, internal dampers or ducts(with secondary air induced by injector action of the primary air F24F1/01)
F24F   1/0284  \	3	3	3L049	F24F   1/0284	403	ʿ˥ե󼴤󤵤줿ΡΣ	
F24F   1/0284 311 \	4	4	3L049	F24F   1/0284	743	ե⡼ĤΤΡ㡥ʿ˥ե󼴤󤷤Τˤƥե⡼ĤΤ	having a single fan motor, e.g. with a single fan motor of which the fan axis is arranged horizontally
F24F   1/0287  \	3	3	3L049	F24F   1/0287	172	ľ˥ե󼴤󤵤줿ΡΣ	
F24F   1/0287 321 \	4	4	3L049	F24F   1/0287	248	ե⡼ĤΤΡ㡥ľ˥ե󼴤󤷤Τˤƥե⡼ĤΤ	having a single fan motor, e.g. with a single fan motor in which fan axes arranged vertically)
F24F   1/029  \	2	2	3L050	F24F   1/029	906	ʡ㡥̵ޤϥե󡤤Υ쥤Ȥޤߤ֤ħΤΡΣ	characterised by the layout or mutual arrangement of components, e.g. of compressors or fans
F24F   1/03  \	2	2	3L052	F24F   1/03	343	դ֤ħΤΡΣ	characterised by mounting arrangements
F24F   1/031  \	3	3	3L052	F24F   1/031	744	ɤ̤ΡΣ	penetrating a wall or window
F24F   1/0314  \	3	3	3L052	F24F   1/0314	68	ɤ˼դΡΣ	mounted on a wall
F24F   1/0317  \	3	3	3L052	F24F   1/0317	182	ŷ椫ߤ뤹ΡΣ	suspended from the ceiling
F24F   1/032  \	2	2	3L051	F24F   1/032	108	Ǯ򴹴ħΤΡΣ	characterised by heat exchangers
F24F   1/0323  \	3	3	3L051	F24F   1/0323	289	Ǯ򴹴μդޤ֡Σ	by the mounting or arrangement of the heat exchangers
F24F   1/0325  \	3	3	3L051	F24F   1/0325	169	Ǯ򴹴ޤϤʡ㡥ե󡤤ηΣ	by the shape of the heat exchangers or of parts thereof, e.g. of their fins
F24F   1/0326  \	2	2	3L051	F24F   1/0326	137	˥åȥˤ롤Ǯ򴹴ﳰ۴ɤ֤ħΤΡΣ	characterised by the arrangement of refrigerant piping outside the heat exchanger within the unit casing
F24F   1/0328  \	2	2	3L051	F24F   1/0328	23	뵤ʡ˧ޤæʣƣƣˡΣ	with means for purifying supplied air(perfuming or deodorising means F24F1/0355)
F24F   1/035  \	3	3	3L051	F24F   1/035	354	ե륿μդޤ֤ħΤΡΣ	characterised by the mounting or arrangement of filters
F24F   1/0353  \	3	3	3L051	F24F   1/0353	212	ŵŪʡ㡥ʥޤʬΥˤΡΣ	by electric means, e.g. ionisers or electrostatic separators
F24F   1/0355  \	2	2	3L051	F24F   1/0355	139	˧ޤæʤͭΡΣ	with perfuming or deodorising means
F24F   1/0358  \	2	2	3L052	F24F   1/0358	1912	ʤͭΡΣ	with dehumidification means
F24F   1/037  \	2	2	3L050	F24F   1/037	846	üʤͭΡΣ	with humidification means
F24F   1/0373  \	2	2	3L050	F24F   1/0373	133	Ǯ֤ħΤΡǮ򴹴ħΤΣƣƣˡΣ	characterised by heating arrangements(characterised by heat exchangers F24F1/032)
F24F   1/0375  \	3	3	3L050	F24F   1/0375	171	ɲäռͼǮǤͭΡ㡥ŵҡΣ	with additional radiant heat-discharging elements, e.g. electric heaters
F24F   1/0378  \	3	3	3L050	F24F   1/0378	113	ǮŤޤǮʤѤΡ㡥ڥǻҡΣ	using thermoelectric or thermomagnetic means, e.g. Peltier elements
F24F   1/039  \	2	2	3L050	F24F   1/039	858	ǽϸΤѤΡ㡥Ž̴ؤλΣ	using water to enhance cooling, e.g. spraying onto condensers
F24F   1/04  \	2	2	3L052	F24F   1/04	146	ӤΤ֡Σ	Arrangements for portability [1,2011.01]
F24F   1/06  \	1	1	3L054	F24F   1/06	367	ʬΥ˥åȡ㡥Υ줿˥åȤ³밵̵Ǯ򴹴狼ʤ뼼˥åȡΣ	Separate outdoor units, e.g. outdoor unit to be linked to a separate room unit comprising a compressor and a heat exchanger
F24F   1/08  \	2	2	3L054	F24F   1/08	120	ʬΥ˥åȤäŬ礷̵Σ	Compressors specially adapted for separate outdoor units [2011.01]
F24F   1/10  \	3	3	3L054	F24F   1/10	331	֤ޤϼդΣ	Arrangement or mounting thereof [2011.01]
F24F   1/12  \	3	3	3L054	F24F   1/12	549	ΤοưޤɻߡΣ	Vibration or noise prevention therefor [2011.01]
F24F   1/14  \	2	2	3L054	F24F   1/14	281	ʬΥ˥åȤäŬ礷Ǯ򴹴Σ	Heat exchangers specially adapted for separate outdoor units [2011.01]
F24F   1/16  \	3	3	3L054	F24F   1/16	1135	֤ޤϼդΣ	Arrangement or mounting thereof [2011.01]
F24F   1/18  \	3	3	3L054	F24F   1/18	706	ηħΤΡΣ	characterised by their shape [2011.01]
F24F   1/20  \	2	2	3L054	F24F   1/20	217	ʬΥ˥åȤΤŵʡΣ	Electric components for separate outdoor units [2011.01]
F24F   1/22  \	3	3	3L054	F24F   1/22	1579	֤ޤϼդΣ	Arrangement or mounting thereof [2011.01]
F24F   1/24  \	3	3	3L054	F24F   1/24	1084	ŵʤѡΣ	Cooling of electric components [2011.01]
F24F   1/26  \	2	2	3L054	F24F   1/26	109	Ѥ۴ɡΣ	Refrigerant piping [2011.01]
F24F   1/28  \	3	3	3L054	F24F   1/28	46	ʣʬΥ˥åȤϢ뤹뤿ΤΡΣ	for connecting several separate outdoor units [2011.01]
F24F   1/30  \	3	3	3L054	F24F   1/30	733	ʬΥ˥åȤǻѤΡΣ	for use inside the separate outdoor units [2011.01]
F24F   1/32  \	3	3	3L054	F24F   1/32	1199	ʬΥ˥åȤ˥åȤϢ뤹뤿ΤΡΣ	for connecting the separate outdoor unit to indoor units [2011.01]
F24F   1/34  \	3	3	3L054	F24F   1/34	341	ݸʡ㡥޴ݸΣ	Protection means therefor, e.g. covers for refrigerant pipes [2011.01]
F24F   1/36  \	2	2	3L054	F24F   1/36	549	˥åȤΤϪΣ	Drip trays for outdoor units [2011.01]
F24F   1/38  \	2	2	3L054	F24F   1/38	1293	˥åȤΥեκ㡥٥ޥޤϥեμդΣ	Fan details of outdoor units, e.g. bell-mouth shaped inlets or fan mountings [2011.01]
F24F   1/40  \	2	2	3L054	F24F   1/40	1039	˥åȼΤοưޤɻߡʼ˥åȤΰ̵ΤΣƣƣˡΣ	Vibration or noise prevention at outdoor units (for outdoor unit compressors F24F 1/12) [2011.01]
F24F   1/42  \	2	2	3L054	F24F   1/42	322	Ž̿ѤħΤΡ㡥ǽϸΤΣ	characterised by the use of the condensate, e.g. for enhanced cooling [2011.01]
F24F   1/44  \	2	2	3L054	F24F   1/44	499	ǳؤѤħΤΡΣ	characterised by the use of internal combustion engines [2011.01]
F24F   1/46  \	2	2	3L054	F24F   1/46	237	ʬΥ˥åȤˤ빽ʤ֡Σ	Component arrangements in separate outdoor units [2011.01]
F24F   1/48  \	3	3	3L054	F24F   1/48	584	ή̤ħΤΡ㡥ήޤήеήΣ	characterised by airflow, e.g. inlet or outlet airflow [2011.01]
F24F   1/50  \	4	4	3L054	F24F   1/50	557	˶᤭ФΡΣ	with outlet air in upward direction [2011.01]
F24F   1/52  \	4	4	3L054	F24F   1/52	82	Ʊ¦̤ήήФԤΡ㡥ɤγ˼դ뤿Σ	Inlet and outlet arranged on the same side, e.g. for mounting in a wall opening [2011.01]
F24F   1/54  \	4	4	3L054	F24F   1/54	71	и¦̤ήήФԤΡΣ	Inlet and outlet arranged on opposite sides [2011.01]
F24F   1/56  \	2	2	3L054	F24F   1/56	1827	ʬΥ˥åȤΤ⤷տ魯륫С㡥ե󥬡ɤޤΣ	Casing or covers of separate outdoor units, e.g. fan guards [2011.01]
F24F   1/58  \	3	3	3L054	F24F   1/58	601	˥åȤ˼դΤݸС㡥۸ɡɻߥСޤϥե顼ΤΥСΣ	Separate protective covers for outdoor units, e.g. solar guards, snow shields or camouflage [2011.01]
F24F   1/60  \	2	2	3L054	F24F   1/60	687	˥åȤ֤ޤϼդΣ	Arrangement or mounting of the outdoor unit [2011.01]
F24F   1/62  \	3	3	3L054	F24F   1/62	264	ɼդΣ	Wall-mounted [2011.01]
F24F   1/64  \	3	3	3L054	F24F   1/64	194	ߤ겼㡥Х륳ˡؤ֡Σ	Ceiling-mounted, e.g. below a balcony [2011.01]
F24F   1/66  \	3	3	3L054	F24F   1/66	113	ַΣ	under the floor level [2011.01]
F24F   1/68  \	3	3	3L054	F24F   1/68	103	ʣʬΥ˥åȤ֡Σ	Arrangement of multiple separate outdoor units [2011.01]
F24F   3/00  \	0	0	3L053	F24F   3/00	40	Ĵ줿򣱸ĤޤϤʾ֤餽ΣΣԤʤäƤ褤ޤ϶֤֤ʬۥ˥åȤ˶뤹ȤζĴΤ褦Τ̤߷פ줿֡ʥ롼˥åȣƣƣ	Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems (room units F24F 1/00)
F24F   3/00  A	0	0	3L053	F24F   3/00	258	ҡݥȥݥפ֤ħΤ	characterised by arrangement of heat pumps
F24F   3/00  B	0	0	3L053	F24F   3/00	1130	Ǯüʤ	with a special heat source
F24F   3/00  C	0	0	3L053	F24F   3/00	45	ɲмʤĤ	having fire-proof means
F24F   3/00  Z	0	0	3L053	F24F   3/00	1283	¾Τ	Others
F24F   3/02  \	1	1	3L053	F24F   3/02	30	ΰϤޤ®٤ˤħŤΡΣ	characterised by the pressure or velocity of the primary air [3]
F24F   3/04  \	2	2	3L053	F24F   3/04	17	ⰵޤϹ®Ǳž	operating with high pressure or high velocity
F24F   3/044  \	1	1	3L053	F24F   3/044	1853	Ƥν֤ͿʤΣ	Systems in which all treatment is given in the central station, i.e. all-air systems [3]
F24F   3/048  \	2	2	3L053	F24F   3/048	161	ή̤ǲ椹ΡΣ	with temperature control at constant rate of air-flow [3]
F24F   3/052  \	3	3	3L053	F24F   3/052	148	ʣ㡥Ǯڤ䵤̸Ĥβϩˤä֤Ĵᤵ줿κ缼˶뤵Σ	Multiple duct systems, e.g. systems in which hot and cold air are supplied by separate circuits from the central station to mixing chambers in the spaces to be conditioned [3]
F24F   3/056  \	2	2	3L053	F24F   3/056	45	ʤȤʬŪ˾ή졤ǮõޤѤΡޤ϶֤˶ؤ뤿Τޤʬۤ뤿οиǡ˷礵줿ΣƣƣˡΣ	the air at least partially flowing over lighting fixtures, the heat of which is dissipated or used (outlets for directing or distributing air into rooms or spaces combined with lighting fixtures F24F 13/078) [3]
F24F   3/06  \	1	1	3L053	F24F   3/06	135	롼˥åȤˤ룱ΣǮήΤζΤ֤ħΤ	characterised by the arrangements for the supply of heat-exchange fluid for the subsequent treatment of primary air in the room units
F24F   3/08  \	2	2	3L053	F24F   3/08	56	ⲹǮήΤ㲹ǮήΤΤʬΥɤӹⲹǮήΤ㲹ǮήΤΤʬΥԴɤȤĤ	with separate supply and return lines for hot and cold heat-exchange fluids
F24F   3/10  \	2	2	3L053	F24F   3/10	28	ⲹǮήΤ㲹ǮήΤΤʬΥɤӹⲹǮήΤ㲹ǮήΤΤζ̤εԴɤȤĤ	with separate supply lines and common return line for hot and cold heat-exchange fluids
F24F   3/12  \	1	1	3L053	F24F   3/12	148	ǮѤȤ̤ζνħȤ	characterised by the treatment of the air otherwise than by heating and cooling
F24F   3/14  \	2	2	3L053	F24F   3/14	3312	üˤΡˤ	by humidification; by dehumidification
F24F   3/147  \	3	3	3L053	F24F   3/147	1606	뵤ӵ֤ǮãӼãʤΡΣ	with both heat and humidity transfer between supplied and exhausted air [3]
F24F   3/153  \	3	3	3L053	F24F   3/153	389	ղŪʲǮͭΡʤ֤ɬפʼ٤Ϳ줿ɬפʲ٤ã뤿˲ǮǤ̲᤹뤳ȤˤΡΣ	with subsequent heating, i.e. with the air, given the required humidity in the central station, passing a heating element to achieve the required temperature [3]
F24F   3/16  \	2	2	3L053	F24F   3/16	1803	ˤΡ㡥ˤΡݤˤΡ󲽤ˤ	by purification, e.g. by filtering; by sterilisation; by ozonisation
F24F   3/163  \	3	3	3L053	F24F   3/163	50	Υơ󡤤ʤᤵ줿̤򤵤줿ΰΣ	Clean air work stations, i.e. selected areas within a space to which filtered air is passed [2021.01]
F24F   3/167  \	3	3	3L053	F24F   3/167	110	꡼롼ࡤʤᤵ줿ζѼή줬ʬۤĺ֡ʷΤɤˤ̵ʬۣƣƣˡΣ	Clean rooms, i.e. enclosed spaces in which a uniform flow of filtered air is distributed (air distribution by perforated walls F24F 7/10) [2021.01]
F24F   5/00  \	0	0	3L054	F24F   5/00	117	ƣƣޤϣƣƣŬѤʤĴޤ϶Ĵ	Air-conditioning systems or apparatus not covered by group F24F 1/00 or F24F 3/00
F24F   5/00  A	0	0	3L054	F24F   5/00	19	Ǯ֥饤ˤ	collecting heat of lighting fixtures by brine
F24F   5/00  H	0	0	3L054	F24F   5/00	30	ܥƥĥݥ֤ˤ	by vortex tubes
F24F   5/00  J	0	0	3L054	F24F   5/00	426	ư֤ߤ	attached to cars
F24F   5/00  K	0	0	3L054	F24F   5/00	1369	ʪΰѤ	using part of buildings
F24F   5/00  L	0	0	3L054	F24F   5/00	903	޲ϩѤ	using of refrigerant circuits
F24F   5/00  Z	0	0	3L054	F24F   5/00	1254	¾Τ	Others
F24F   5/00 101 \	1	1	3L054	F24F   5/00	60	֥饤ݥ˥ĥȤ˶뤹	supplying brine to room units
F24F   5/00 101 A	1	0	3L054	F24F   5/00	589	Ǯüʤ	with a special heat source
F24F   5/00 101 B	1	0	3L054	F24F   5/00	1137	ռͼǮ򴹴Ĥ	having radiation heat exchangers
F24F   5/00 101 Z	1	0	3L054	F24F   5/00	2462	¾Τ	Others
F24F   5/00 102 \	2	2	3L054	F24F   5/00	44	ǮʤĤ	having heat storage means
F24F   5/00 102 A	2	0	3L054	F24F   5/00	49	ưϲʤĤ	having power recovering means
F24F   5/00 102 B	2	0	3L054	F24F   5/00	100	֥饤ȶƱ˽	processing brine and air simultaneously
F24F   5/00 102 C	2	0	3L054	F24F   5/00	1387	Ǯʣͥ	Heat storage parts (K takes precedence)
F24F   5/00 102 K	2	0	3L054	F24F   5/00	742	ɹǮ	Ice heat storage
F24F   5/00 102 L	2	1	3L054	F24F   5/00	266	Ѥˤɹ¤	Producing ice by supercooling
F24F   5/00 102 M	2	2	3L054	F24F   5/00	224	ǮΤߤħ	characterised solely by heat storage
F24F   5/00 102 N	2	3	3L054	F24F   5/00	127	Ѳʡɻ߼	Supercooling-releasing means or supercooling-preventing means
F24F   5/00 102 S	2	1	3L054	F24F   5/00	163	Ǯμɹ¤	Producing ice around heat exchanging members
F24F   5/00 102 T	2	2	3L054	F24F   5/00	180	ǮΤߤħ	characterised solely by heat storage
F24F   5/00 102 W	2	1	3L054	F24F   5/00	93	ޤȤľܿˤɹ¤	Producing ice by direct contact with antifreezing refrigerant
F24F   5/00 102 Z	2	0	3L054	F24F   5/00	2308	¾Τ	Others
F24F   6/00  \	0	0	3L055	F24F   6/00	50	üΣ	Air-humidification [3]
F24F   6/00  A	0	0	3L055	F24F   6/00	1822	̥󥯡󥯤ޤꡤĴ	Supplying water (tanks, tank peripherals or water level adjustment)
F24F   6/00  B	0	0	3L055	F24F   6/00	1266	ήϩ̥ݥήϩϪкòиߥ͡ݥ	Air channels (steam channels, condensation measures, noise reduction, outlets or eliminators)
F24F   6/00  C	0	0	3L055	F24F   6/00	648	Խʪк̿Ρե륿岽򴹼顤ݡ	Impurity measures (water quality detection, filters, water softening, ion exchange resin and cleaning)
F24F   6/00  D	0	0	3L055	F24F   6/00	813	ݡȯɻ	Sterilisation and prevention of algae
F24F   6/00  E	0	0	3L055	F24F   6/00	1077	١٤θΡ̣ƣƣ¤ͥ	Detecting and controlling temperature or humidity (F 24 F 6/12, 101 B takes precedence)
F24F   6/00  F	0	0	3L055	F24F   6/00	430	кϿ̴Ρžкнкɻߡʲɻߡżǡ	Safety measures (seismic detection, anti-tumbling measures, anti-burn measures, electric shock prevention, empty cooking prevention or electricity shutoff in case of danger)
F24F   6/00  G	0	0	3L055	F24F   6/00	296	ɽ̱žߡ̡ʥ󥯤˴ؤΤϡƣƣͥˡ	Indication [operation, suspension or water level (F 24 F 6/00 A takes precedence for tanks)
F24F   6/00  H	0	0	3L055	F24F   6/00	433	ӽӿӿХ֤	Removing or draining spilled water (control of drain valves)
F24F   6/00  Z	0	0	3L055	F24F   6/00	720	¾̶Ĵʳ֤˼դü˧źá	Others (humidifiers mounted in units other than air-conditioning apparatus or perfume addition)
F24F   6/00 301 \	1	1	3L055	F24F   6/00	984	ݥ˥ĥ	Room units
F24F   6/00 311 \	2	2	3L055	F24F   6/00	824	ݥ˥ĥȤǳƼ˼֤Ǥ	being warm-air heaters of combustion type
F24F   6/00 321 \	2	2	3L055	F24F   6/00	365	ݥ˥ĥȤ弰˼֤Ǥ	being  hot-water heaters
F24F   6/00 331 \	2	2	3L055	F24F   6/00	1138	ݥ˥ĥȤҡݥȥݥ׼˼֤Ǥ	being  heat pump heaters
F24F   6/00 341 \	2	2	3L055	F24F   6/00	407	ݥ˥ĥȤȡݥ֤Ǥ	being  stoves
F24F   6/02  \	1	1	3L055	F24F   6/02	16	οξȯˤΡΣ	by evaporation of water in the air [3]
F24F   6/02  A	1	0	3L055	F24F   6/02	307	ʤǮˤΡ̣ƣƣͥ	by heating without wet elements (F 24 F 6/12, 101 A takes precedence)
F24F   6/02  B	1	1	3L055	F24F   6/02	875	ʤŵǮˤ	by electric heating without wet elements
F24F   6/02  Z	1	0	3L055	F24F   6/02	147	¾	Others
F24F   6/04  \	2	2	3L055	F24F   6/04	2222	ŻߤǮμѤΡΣ	using stationary unheated wet elements [3]
F24F   6/06  \	2	2	3L055	F24F   6/06	870	ưǮμѤΡΣ	using moving unheated wet elements [3]
F24F   6/08  \	2	2	3L055	F24F   6/08	554	Ǯ줿ѤΡΣ	using heated wet elements [3]
F24F   6/10  \	3	3	3L055	F24F   6/10	515	ŵŪ˲ǮΡΣ	heated electrically [3]
F24F   6/12  \	1	1	3L055	F24F   6/12	138	ǿۤ뤳ȤˤΡΣ	by forming water dispersions in the air[2006.01]
F24F   6/12 101 \	2	2	3L055	F24F   6/12	86	ĶȤˤ	by ultrasonics
F24F   6/12 101 A	2	0	3L055	F24F   6/12	128	ǮĤ	having heating members
F24F   6/12 101 B	2	0	3L055	F24F   6/12	247	ĶȲü̼ϡƣƣ	Control of ultrasonic humidifiers (mainly F 24 F 11/10)
F24F   6/12 101 Z	2	0	3L055	F24F   6/12	1702	¾ĶȲü̡	Others (ultrasonic humidifiers in general)
F24F   6/14  \	2	2	3L055	F24F   6/14	786	ΥѤΡΣ	using nozzles [3]
F24F   6/16  \	2	2	3L055	F24F   6/16	714	žѤΡΣ	using rotating elements [3]
F24F   6/18  \	1	1	3L055	F24F   6/18	282	ؤξʮͤˤΡΣ	by injection of steam into the air [3]
F24F   7/00  \	0	0	3L056	F24F   7/00	384		Ventilation
F24F   7/00  C	0	0	3L056	F24F   7/00	185	ѤƴΡ㡥	Ventilating through under-floor space, e.g., natural ventilation
F24F   7/00  D	0	0	3L056	F24F   7/00	129	ߤޤϸѤƴΡ㡥	Ventilating through visors or eaves, e.g., natural ventilation
F24F   7/00  E	0	0	3L056	F24F   7/00	58	Ѵ	Ventilation for vehicles
F24F   7/00  Z	0	0	3L056	F24F   7/00	1323	¾㡥	Others, e.g., natural ventilation
F24F   7/003  \	1	1	3L056	F24F   7/003	1572	Ȥ߹蘆ΡΣ	in combination with air cleaning [2021.01]
F24F   7/003 100 \	2	2	3L056	F24F   7/003	308	ȯޤ	including ion generating apparatus
F24F   7/007  \	1	1	3L056	F24F   7/007	62	ήˤΡʥ֤ѤΣƣƣˡΣ	with forced flow (using ducting systems F24F 7/06) [3]
F24F   7/007  B	1	0	3L056	F24F   7/007	6043		Controlling ventilation
F24F   7/007  C	1	1	3L056	F24F   7/007	590	Ϣư	Controlling ventilation with interlock with gas apparatus
F24F   7/007  D	1	0	3L056	F24F   7/007	530	оݤüʤ	with a special target to be ventilated
F24F   7/007  Z	1	0	3L056	F24F   7/007	469	¾Τ	Others
F24F   7/007 101 \	2	2	3L056	F24F   7/007	1255	졼ˤ	by circulators
F24F   7/013  \	2	2	3L057	F24F   7/013	82	ɤޤ̤ƶ촹륦եޤϥɥեѤΡΣ	using wall or window fans, displacing air through the wall or window [3]
F24F   7/013 101 \	3	3	3L057	F24F   7/013	35	եˤ	by wall-mounted fans
F24F   7/013 101 A	3	0	3L057	F24F   7/013	912	åĤ	with shutters
F24F   7/013 101 P	3	1	3L057	F24F   7/013	717	ɳ	of pull-string type
F24F   7/013 101 Q	3	1	3L057	F24F   7/013	461		Wind pressure type
F24F   7/013 101 R	3	1	3L057	F24F   7/013	181	ѥ⡼ˤ	by dedicated motors
F24F   7/013 101 S	3	1	3L057	F24F   7/013	172	ե⡼ˤ	by fan motors
F24F   7/013 101 T	3	1	3L057	F24F   7/013	35	ˤ	by shape memory alloys
F24F   7/013 101 U	3	1	3L057	F24F   7/013	1926	ư	by rocking type
F24F   7/013 101 V	3	2	3L057	F24F   7/013	468	ñ	by veneer
F24F   7/013 101 W	3	1	3L057	F24F   7/013	51	ľư	of close coupled type
F24F   7/013 101 B	3	0	3L057	F24F   7/013	513	åϢưåĤ	with switches linked with shutters
F24F   7/013 101 C	3	0	3L057	F24F   7/013	395	Ʊӷ	of simultaneous suction/exhaust type
F24F   7/013 101 D	3	0	3L057	F24F   7/013	877	°㡥С	Constructions of accessories, e.g., covers
F24F   7/013 101 G	3	1	3L057	F24F   7/013	762	ե륿ħ	characterised by filters
F24F   7/013 101 H	3	1	3L057	F24F   7/013	249	ħ	characterised by oil trays
F24F   7/013 101 J	3	1	3L057	F24F   7/013	280	ŵޤŵμդħ	characterised by installation of electric wires or electric apparatus
F24F   7/013 101 K	3	1	3L057	F24F   7/013	67	Υħ	characterised by releasable coatings
F24F   7/013 101 L	3	1	3L057	F24F   7/013	255	Сħ	characterised by weather covers
F24F   7/013 101 M	3	1	3L057	F24F   7/013	246	òޤǮħ	characterised by noise reduction or heat insulation
F24F   7/013 101 N	3	1	3L057	F24F   7/013	230	̥ѥͥޤϥǥե塼ħ	characterised by front panels or diffusers
F24F   7/013 101 E	3	0	3L057	F24F   7/013	610	Ω	Assembly
F24F   7/013 101 F	3	0	3L057	F24F   7/013	607	֡㡥	Attachment, e.g., mounting frames
F24F   7/013 101 X	3	0	3L057	F24F   7/013	152	ήʴή˥եѤ	using of drift (one-through) fans
F24F   7/013 101 Y	3	0	3L057	F24F   7/013	308	󿴥եѤ	using of centrifugal fans
F24F   7/013 101 Z	3	0	3L057	F24F   7/013	510	¾Τ	Others
F24F   7/013 102 \	3	3	3L057	F24F   7/013	2	ɥեˤ	by wind fans
F24F   7/013 102 A	3	0	3L057	F24F   7/013	165	°	Constructions of accessories
F24F   7/013 102 D	3	1	3L057	F24F   7/013	70	ޤϥե륿ħ	characterised by oil trays or filters
F24F   7/013 102 E	3	1	3L057	F24F   7/013	122	ŵޤŵμդħ	characterised by installation of electric wires or apparatus
F24F   7/013 102 F	3	1	3L057	F24F   7/013	60	òޤǮħ	characterised by noise reduction or heat insulation
F24F   7/013 102 G	3	1	3L057	F24F   7/013	161	οɻߤħ	characterised by prevention of wind and rain from entering
F24F   7/013 102 B	3	0	3L057	F24F   7/013	590	Ωޤ	Assembly or installation
F24F   7/013 102 C	3	0	3L057	F24F   7/013	170	Τưʤ	with mobile main bodies
F24F   7/013 102 H	3	0	3L057	F24F   7/013	244	ӵ	conducting suction/exhaustion
F24F   7/013 102 J	3	0	3L057	F24F   7/013	333	ήʴή˥եѤ	using of drifting (one-through) fans
F24F   7/013 102 K	3	0	3L057	F24F   7/013	54	󿴥եѤ	using of centrifugal fans
F24F   7/013 102 Z	3	0	3L057	F24F   7/013	308	¾Τ	Others
F24F   7/02  \	1	1	3L057	F24F   7/02	7	崹ʲդδţġˡΣ	Roof ventilation (ventilation of roof coverings E04D) [3,6]
F24F   7/02  K	1	0	3L057	F24F   7/02	569		Natural ventilation
F24F   7/02  L	1	0	3L057	F24F   7/02	467		Forced ventilation
F24F   7/02  M	1	1	3L057	F24F   7/02	46	ӤĤ	having solar batteries
F24F   7/02  A	1	0	3L057	F24F   7/02	145	°	Constructions of accessories
F24F   7/02  D	1	1	3L057	F24F   7/02	144		dampers
F24F   7/02  E	1	2	3L057	F24F   7/02	60	ư϶ư	Power operation
F24F   7/02  F	1	2	3L057	F24F   7/02	37	ˤ	by shape memory alloys
F24F   7/02  G	1	1	3L057	F24F   7/02	51	òޤǮ	Noise reduction or heat insulation
F24F   7/02  H	1	1	3L057	F24F   7/02	37	ɲ	Filtering
F24F   7/02  J	1	1	3L057	F24F   7/02	10		Lighting fixtures
F24F   7/02  B	1	0	3L057	F24F   7/02	143	Ωޤ	Assembly or installation
F24F   7/02  C	1	0	3L057	F24F   7/02	214	ﹽ¤ħ	characterised by constructions of ridges
F24F   7/02  Z	1	0	3L057	F24F   7/02	537	¾ΤΡ㡥եʤ롼ե٥졼	Others, e.g., roof ventilators without fans
F24F   7/04  \	1	1	3L058	F24F   7/04	30	ȷĤ	with ducting systems
F24F   7/04  A	1	0	3L058	F24F   7/04	528	ϴ	Wind force ventilation
F24F   7/04  B	1	0	3L058	F24F   7/04	1740	ռ㡥٥ȥåפޤϴ	Natural ventilation with ducts, e.g., vent-caps or ventilating holes
F24F   7/04  Z	1	0	3L058	F24F   7/04	932	¾Τ	Others
F24F   7/06  \	2	2	3L058	F24F   7/06	122	۴ļʤĤΡ㡥ˤ	with forced air circulation, e.g. by fan
F24F   7/06  A	2	0	3L058	F24F   7/06	581	ե졼	Air circulators with ducts
F24F   7/06  B	2	0	3L058	F24F   7/06	2623	оݤüʤ	with a special target to be ventilated
F24F   7/06  H	2	1	3L058	F24F   7/06	112	١	for lifts
F24F   7/06  J	2	1	3L058	F24F   7/06	34		for safes
F24F   7/06  K	2	1	3L058	F24F   7/06	259	ܼˤޤϷܼ	for livestock barns or fowl houses
F24F   7/06  M	2	1	3L058	F24F   7/06	120		for greenhouses
F24F   7/06  N	2	1	3L058	F24F   7/06	57	Ҹ	for warehouses
F24F   7/06  P	2	1	3L058	F24F   7/06	59	ޤϲȢ	for closets or shoe storage cabinets
F24F   7/06  Q	2	1	3L058	F24F   7/06	107	ϥץ	for nuclear power plants
F24F   7/06  R	2	1	3L058	F24F   7/06	130		for painting
F24F   7/06  C	2	0	3L058	F24F   7/06	4901	꡼롼ʥɥեȥС£̣¡Хˡ£̣á£ģ	Clean rooms (draft chambers, B01L1/00B, bio-cleaning storage, B01L1/00C, B01D53/26 230)
F24F   7/06  D	2	0	3L058	F24F   7/06	385	ﴹ	Emergency ventilation
F24F   7/06  F	2	0	3L058	F24F   7/06	454	ȥͥ봹ʥȥͥ봹ţơ	Tunnel ventilating fans (tunnel ventilation E21F)
F24F   7/06  G	2	0	3L058	F24F   7/06	260	æ	Deodorant ventilating fans
F24F   7/06  L	2	0	3L058	F24F   7/06	716	紹	Collective ventilation
F24F   7/06  S	2	0	3L058	F24F   7/06	350	ѥѴ	Ventilating fans for pipes
F24F   7/06  Z	2	0	3L058	F24F   7/06	1146	¾Τ	Others
F24F   7/06 101 \	3	3	3L058	F24F   7/06	79	ȷΰޤϥȤȤӵաɤѤ	using exhaust hoods as parts of a ducting system or as ducts
F24F   7/06 101 A	3	0	3L058	F24F   7/06	2364	°㡥ե륿ݡڤޤ	Constructions of accessories, e.g., filters, oil shields or oil trays
F24F   7/06 101 B	3	0	3L058	F24F   7/06	1450	Ωޤ֡㡥Фաݥ	Assembly or installation, e.g., pull-out hoods
F24F   7/06 101 Z	3	0	3L058	F24F   7/06	2610	¾ΤΡ㡥³ޤϥѡ	Others, e.g., duct connection ports or dampers
F24F   7/08  \	3	3	3L059	F24F   7/08	45	뵤ӵΤ̸ĤΥȤĤΡΣ	with separate ducts for supplied and exhausted air [3]
F24F   7/08  A	3	0	3L059	F24F   7/08	929	ĴµߤΤ	installed in air conditioning apparatus
F24F   7/08  Z	3	0	3L059	F24F   7/08	971	¾Τ	Others
F24F   7/08 101 \	4	4	3L059	F24F   7/08	90	Ǯ򴹷	Ventilating fans of heat exchange type
F24F   7/08 101 A	4	0	3L059	F24F   7/08	635	Ǯ򴹴ħΡǮ򴹴ƣơġ	characterised by heat exchangers (heat exchangers F28F,D)
F24F   7/08 101 B	4	0	3L059	F24F   7/08	2018	ľǮ򴹴Ĥ	with orthogonal heat exchangers
F24F   7/08 101 C	4	0	3L059	F24F   7/08	423	žǮ򴹴Ĥ	with rotating heat exchangers
F24F   7/08 101 D	4	0	3L059	F24F   7/08	448	иήǮ򴹴Ĥ	with counterflow heat exchangers
F24F   7/08 101 E	4	0	3L059	F24F   7/08	145	ҡȥѥפĤ	with heat pipes
F24F   7/08 101 F	4	0	3L059	F24F   7/08	92	ΤǮ򴹵ǽĤ	with the blower per se having heat exchanging features
F24F   7/08 101 G	4	0	3L059	F24F   7/08	1275	Ωޤ	Assembly or installation
F24F   7/08 101 H	4	1	3L059	F24F   7/08	128	Ǯ򴹴μդ	Mounting of heat exchangers
F24F   7/08 101 J	4	0	3L059	F24F   7/08	910	桤ΤޤɽʤĤ	having control, detection and display means
F24F   7/08 101 K	4	0	3L059	F24F   7/08	1505	°	Constructions of accessories
F24F   7/08 101 L	4	1	3L059	F24F   7/08	855	ѡޤϥå	Dampers or shutters
F24F   7/08 101 M	4	1	3L059	F24F   7/08	420	Ϫɻߤޤϥҡ	Condensation prevention or heaters
F24F   7/08 101 N	4	1	3L059	F24F   7/08	397	ɲ	Filtering
F24F   7/08 101 P	4	1	3L059	F24F   7/08	215	ɥȴ	Draining
F24F   7/08 101 Q	4	1	3L059	F24F   7/08	177	ɲޤǮ	Sound or heat insulation
F24F   7/08 101 Z	4	0	3L059	F24F   7/08	2078	¾Τ	Others
F24F   7/10  \	3	3	3L059	F24F   7/10	51	Τɡޤŷ̤Ƶ뵤ޤӵΡʶŤޤʬۤ뤿ƣƣˡΣ	with air supply, or exhaust, through perforated wall, floor or ceiling (outlet members for directing or distributing air F24F 13/06) [3]
F24F   7/10  A	3	0	3L059	F24F   7/10	617		Underfloor ventilation
F24F   7/10  Z	3	0	3L059	F24F   7/10	1507	¾Τ	Others
F24F   7/10 101 \	4	4	3L059	F24F   7/10	41	ŷ̤Ƥʤ	through ceiling
F24F   7/10 101 A	4	0	3L059	F24F   7/10	485	°㡥ե륿ޤϵ۹	Construction of accessories, e.g., filters or suction grills
F24F   7/10 101 C	4	1	3L059	F24F   7/10	341	۹	Suction grills
F24F   7/10 101 D	4	1	3L059	F24F   7/10	203	ɲ	Filtering
F24F   7/10 101 E	4	1	3L059	F24F   7/10	252	ɲޤǮ	Sound or heat insulation
F24F   7/10 101 F	4	1	3L059	F24F   7/10	313	ŵޤŵ	Electric wires or electric apparatus
F24F   7/10 101 B	4	0	3L059	F24F   7/10	1134	Ωޤ	Assembly or installation
F24F   7/10 101 G	4	0	3L059	F24F   7/10	11	Ĥ˵۹Τʤ	without inlets on the base plates
F24F   7/10 101 Z	4	0	3L059	F24F   7/10	1237	¾ΤΡ㡥³ޤϥѡ	Others, e.g., duct connection ports or dampers
F24F   8/00  \	0	0	3L208	F24F   8/00	12	ͤν֤ޤϺȶ֤˶뤵ΡǮѡüޤϽʳν㡥Σ	Treatment, e.g. purification, of air supplied to human living or working spaces otherwise than by heating, cooling, humidifying or drying [2021.01]
F24F   8/00 999 \	1	1	3L208	F24F   8/00	848	ϤΤΥߡƣɡڿͿߡ	Dummy FI for reclassification [New assignment suspended]
F24F   8/10  \	1	1	3L208	F24F   8/10	71	ʬΥˤΡ㡥ˤΡΣ	by separation, e.g. by filtering [2021.01]
F24F   8/108  \	2	2	3L208	F24F   8/108	232	ե륿ǤѤΡΣ	using dry filter elements [2021.01]
F24F   8/108 100 \	3	3	3L208	F24F   8/108	285	ե륿Ǥ֤ħ	characterised by the arrangements of filter elements
F24F   8/108 110 \	4	4	3L208	F24F   8/108	1915	ե륿Ǥե¦֤	Filter elements arranged on the windward side of fans
F24F   8/108 120 \	4	4	3L208	F24F   8/108	412	ե륿Ǥե¦֤	Filter elements arranged on the leeward side of fans
F24F   8/108 200 \	3	3	3L208	F24F   8/108	464	ե륿Ǥμդħ	characterised by installation of filter elements
F24F   8/108 210 \	4	4	3L208	F24F   8/108	1661	ե륿ǤǤ	Filter elements being fixed
F24F   8/108 220 \	4	4	3L208	F24F   8/108	273	ե륿ǤưǤΡʾ֤ݤΤΤΤϣƣƣ	Filter elements being movable (for cleaning of purification apparatusF24F8/90,130)
F24F   8/108 230 \	5	5	3L208	F24F   8/108	149	ž	being rotatable
F24F   8/108 300 \	3	3	3L208	F24F   8/108	74	ʣΥե륿Ǥ뤳Ȥħ	characterised by having multiple filter elements
F24F   8/108 310 \	4	4	3L208	F24F   8/108	897	ήФե륿Ǥľ֤	Filter elements arranged in series along the direction of air flow
F24F   8/108 320 \	4	4	3L208	F24F   8/108	248	ήФե륿Ǥ֤	Filter elements arranged in parallel to the direction of air flow
F24F   8/108 330 \	4	4	3L208	F24F   8/108	48	ե륿ǤŪ˻Ѥ	using filter elements selectively
F24F   8/117  \	2	2	3L208	F24F   8/117	45	ѤΡΣ	using wet filtering [2021.01]
F24F   8/125  \	3	3	3L208	F24F   8/125	262	ե륿ǤѤΡΣ	using wet filter elements [2021.01]
F24F   8/133  \	3	3	3L208	F24F   8/133	730	Ρ㡥ʮ̸աȤľܿˤΡΣ	by direct contact with liquid, e.g. with sprayed liquid [2021.01]
F24F   8/142  \	3	3	3L208	F24F   8/142	75	ѺѤ߱Τν㡥ѤΤξΣ	Treatment of used liquid, e.g. cleaning for recycling [2021.01]
F24F   8/15  \	2	2	3L208	F24F   8/15	1082	ŪʤˤΡΣ	by chemical means [2021.01]
F24F   8/158  \	3	3	3L208	F24F   8/158	928	úѤΡΣ	using active carbon [2021.01]
F24F   8/167  \	3	3	3L208	F24F   8/167	1273	ȿѤΡΣ	using catalytic reactions [2021.01]
F24F   8/175  \	2	2	3L208	F24F   8/175	174	ʪŪʪޤʪѤΡΣ	using biological materials, plants or microorganisms [2021.01]
F24F   8/183  \	2	2	3L208	F24F   8/183	96	ʬΥˤΡ㡥ѤΡΣ	by centrifugal separation, e.g. using vortices [2021.01]
F24F   8/192  \	2	2	3L208	F24F   8/192	2063	ŵŪʤˤΡ㡥ųޤϹŰΰäˤΡΣ	by electrical means, e.g. by applying electrostatic fields or high voltages [2021.01]
F24F   8/20  \	1	1	3L208	F24F   8/20	325	ݤˤΡΣ	by sterilisation [2021.01]
F24F   8/22  \	2	2	3L208	F24F   8/22	896	糰ѤΡΣ	using UV light [2021.01]
F24F   8/24  \	2	2	3L208	F24F   8/24	1348	ΤѤΡΣ	using sterilising media [2021.01]
F24F   8/26  \	3	3	3L208	F24F   8/26	540	ѤΡΣ	using ozone [2021.01]
F24F   8/28  \	2	2	3L208	F24F   8/28	4	쥸ͥ°ݤνݤޤϴäŬΡΣ	specially adapted for combatting or avoiding Legionella bacteria [2021.01]
F24F   8/30  \	1	1	3L208	F24F   8/30	2305	󲽤ˤΡΣ	by ionisation [2021.01]
F24F   8/40  \	1	1	3L208	F24F   8/40	337	󲽤ˤΡʻݤΤΤΣƣƣˡΣ	by ozonisation (for sterilisation F24F 8/26) [2021.01]
F24F   8/50  \	1	1	3L208	F24F   8/50	687	ˤΡΣ	by odorisation [2021.01]
F24F   8/60  \	1	1	3L208	F24F   8/60	250	ǤźäˤΡΣ	by adding oxygen [2021.01]
F24F   8/70  \	1	1	3L208	F24F   8/70	3	ɥνˤΡΣ	by removing radon [2021.01]
F24F   8/80  \	1	1	3L208	F24F   8/80	108	ǼΣ	Self-contained air purifiers [2021.01]
F24F   8/80 100 \	2	2	3L208	F24F   8/80	120	ȢΤħ	characterised by casings or covers
F24F   8/80 110 \	3	3	3L208	F24F   8/80	787	ȢΤι¤˴ؤ	related to the structures of casings or covers
F24F   8/80 115 \	4	4	3L208	F24F   8/80	234	̥ѥͥ롤㡥	Front panels, e.g., ornamental plates
F24F   8/80 120 \	3	3	3L208	F24F   8/80	176	֤˴ؤ	related to installation
F24F   8/80 125 \	4	4	3L208	F24F   8/80	196	ɤ˼դ	attached on the wall
F24F   8/80 130 \	4	4	3L208	F24F   8/80	352	ŷ˼դ	attached to the ceiling
F24F   8/80 135 \	4	4	3L208	F24F   8/80	268	֤ι¤㡥Ӥޤϥ㥹ħ	characterised by structures placed on the floor, e.g., legs or casters
F24F   8/80 140 \	3	3	3L208	F24F   8/80	725	ŵʤμդޤ֤ħ	characterised by installation or arrangement of electric components
F24F   8/80 145 \	4	4	3L208	F24F   8/80	180	ʡ㡥	Control means, e.g., control boards
F24F   8/80 150 \	4	4	3L208	F24F   8/80	522	㡥	Detection units, e.g., sensors
F24F   8/80 155 \	4	4	3L208	F24F   8/80	414	μʡ㡥ɽʤޤϥԡ	Notification means, e.g., display means or speakers
F24F   8/80 160 \	4	4	3L208	F24F   8/80	151		Operation means
F24F   8/80 165 \	4	4	3L208	F24F   8/80	154	Ȥϼʡ㡥̿	Means to transmit data to or to receive data from external equipment, e.g., communication means
F24F   8/80 170 \	3	3	3L208	F24F   8/80	167	ࡤ㡥ļ	Auxiliary members, e.g., handles
F24F   8/80 200 \	2	2	3L208	F24F   8/80	578	ήϩħ	characterised by airflow channels
F24F   8/80 210 \	3	3	3L208	F24F   8/80	158	۹	Suction ports
F24F   8/80 212 \	4	4	3L208	F24F   8/80	528	̤ۤ	sucking in from the front
F24F   8/80 214 \	4	4	3L208	F24F   8/80	150	̤ۤ	sucking in from the back
F24F   8/80 216 \	4	4	3L208	F24F   8/80	484	¦̤ۤ	sucking in from the sides
F24F   8/80 218 \	4	4	3L208	F24F   8/80	255	̤ۤ	sucking in from the top
F24F   8/80 220 \	4	4	3L208	F24F   8/80	271	̤ۤ	sucking in from the bottom
F24F   8/80 222 \	4	4	3L208	F24F   8/80	110	ưࡤ㡥롼С	having movable members, e.g., louvers
F24F   8/80 230 \	3	3	3L208	F24F   8/80	145	и	Blowout ports
F24F   8/80 232 \	4	4	3L208	F24F   8/80	233	̤᤭Ф	blowing out from the front
F24F   8/80 234 \	4	4	3L208	F24F   8/80	66	̤᤭Ф	blowing out from the back
F24F   8/80 236 \	4	4	3L208	F24F   8/80	337	¦̤᤭Ф	blowing out from the sides
F24F   8/80 238 \	4	4	3L208	F24F   8/80	781	̤᤭Ф	blowing out from the top
F24F   8/80 240 \	4	4	3L208	F24F   8/80	211	̤᤭Ф	blowing out from the bottom
F24F   8/80 242 \	4	4	3L208	F24F   8/80	414	ưࡤ㡥롼С	having movable members, e.g., louvers
F24F   8/80 250 \	3	3	3L208	F24F   8/80	181		Ducts
F24F   8/80 252 \	4	4	3L208	F24F   8/80	355	ή	with air-flow control members
F24F   8/80 254 \	5	5	3L208	F24F   8/80	206		Dampers
F24F   8/80 260 \	3	3	3L208	F24F   8/80	450	ήϩʣ	with multiple airflow channels
F24F   8/80 300 \	2	2	3L208	F24F   8/80	1006	ʡ㡥ե󡤤ħ	characterised by air blowing means, e.g., fans
F24F   8/80 310 \	3	3	3L208	F24F   8/80	243	ʣʤ	with multiple air blowing means
F24F   8/80 400 \	2	2	3L208	F24F   8/80	639	üʤ뤳Ȥħ	characterised by having humidifying means
F24F   8/80 500 \	2	2	3L208	F24F   8/80	48	ΧŪ˰ư㡥Ԥޤԡ	moving autonomously, e.g., running or flying
F24F   8/90  \	1	1	3L208	F24F   8/90	134	֤ݡΣ	Cleaning of purification apparatus [2021.01]
F24F   8/90 100 \	2	2	3L208	F24F   8/90	172	ե륿Ǥݤ	cleaning dry filter elements
F24F   8/90 110 \	3	3	3L208	F24F   8/90	501	ݼʡ㡥֥饷ư	by moving cleaning means, e.g., brushes
F24F   8/90 120 \	3	3	3L208	F24F   8/90	581	ݼʡ㡥֥饷ưʤ	by not moving cleaning means, e.g., brushes
F24F   8/90 130 \	3	3	3L208	F24F   8/90	815	ե륿Ǥư	by moving dry filter elements
F24F   8/90 140 \	3	3	3L208	F24F   8/90	818	ὸʪ㡥Լν	Disposal of sweepings captured and collected, e.g., dust
F24F   8/95  \	1	1	3L208	F24F   8/95	359	ŪäŬΡΣ	specially adapted for specific purposes [2021.01]
F24F   8/96  \	2	2	3L208	F24F   8/96	63	ʴ뤿ΤΡΣ	for removing pollen [2021.01]
F24F   8/97  \	2	2	3L208	F24F   8/97	353	Фα뤿ΤΡΣ	for removing tobacco smoke [2021.01]
F24F   8/98  \	2	2	3L208	F24F   8/98	185	뤿ΤΡΣ	for removing ozone [2021.01]
F24F   8/99  \	2	2	3L208	F24F   8/99	33	Ի㡥ƻϩζ뤿ΤΡΣ	for treating air sourced from urban areas, e.g. from streets [2021.01]
F24F   9/00  \	0	0	3L059	F24F   9/00	938	ؤΤεήѡ㡥ƥ	Use of air currents for screening, e.g. air curtain
F24F   9/00  A	0	0	3L059	F24F   9/00	1077	Ʒ	Upright
F24F   9/00  B	0	0	3L059	F24F   9/00	180		Lateral type
F24F   9/00  C	0	0	3L059	F24F   9/00	193	ʿ	Horizontal
F24F   9/00  D	0	0	3L059	F24F   9/00	71	и	Counterflow
F24F   9/00  E	0	0	3L059	F24F   9/00	387	۹Ĥ	with inlets
F24F   9/00  F	0	1	3L059	F24F   9/00	313	۴ļ	of circulating type
F24F   9/00  G	0	0	3L059	F24F   9/00	538	ߤ	installed in entrances or exits
F24F   9/00  H	0	0	3L059	F24F   9/00	63	ϭϩߤ	installed in corridors or passages
F24F   9/00  J	0	0	3L059	F24F   9/00	236		Control
F24F   9/00  K	0	0	3L059	F24F   9/00	65	°	Constructions of accessories
F24F   9/00  L	0	1	3L059	F24F   9/00	302	ή	Air-flow-controlling members
F24F   9/00  M	0	2	3L059	F24F   9/00	182	Ĵ	Regulating wind direction
F24F   9/00  N	0	1	3L059	F24F   9/00	69	ҡݥ	Heaters or lighting fixtures
F24F   9/00  Z	0	0	3L059	F24F   9/00	81	¾	Others
F24F  11/00  \	0	0	3L260	F24F  11/00    ;F24F 110/00    ;F24F 120/00    ;F24F 130/00    ;F24F 140/00	63	ޤϰޤϤ֡Σ	Control or safety arrangements [2018.01]
F24F  11/30  \	1	1	3L260	F24F  11/30	366	ƥư˴ϢŪΤΡ㡥ޤϴƻΤΣ	for purposes related to the operation of the system, e.g. for safety or monitoring [2018.01]
F24F  11/32  \	2	2	3L260	F24F  11/32	1419	ξޤ϶۵޻֤˱ΡΣ	Responding to malfunctions or emergencies [2018.01]
F24F  11/33  \	3	3	3L260	F24F  11/33	4092	лԽޤϱؤαΣ	to fire, excessive heat or smoke [2018.01]
F24F  11/34  \	4	4	3L260	F24F  11/34	107	̵ϩγˤΡΣ	by opening air passages [2018.01]
F24F  11/35  \	4	4	3L260	F24F  11/35	15	̵ϩĺˤΡΣ	by closing air passages [2018.01]
F24F  11/36  \	3	3	3L260	F24F  11/36	990	ǮήΤϳؤαΣ	to leakage of heat-exchange fluid [2018.01]
F24F  11/37  \	3	3	3L260	F24F  11/37	307	Ƶư㡥Ÿ塨۵޻ưΣ	Resuming operation, e.g. after power outages; Emergency starting [2018.01]
F24F  11/38  \	3	3	3L260	F24F  11/38	820	ξǡΣ	Failure diagnosis [2018.01]
F24F  11/39  \	3	3	3L260	F24F  11/39	1345	ե륿ǽƻΣ	Monitoring filter performance [2018.01]
F24F  11/41  \	2	2	3L260	F24F  11/41	1784	ɻߡΣ	Defrosting; Preventing freezing [2018.01]
F24F  11/41 100 \	3	3	3L260	F24F  11/41	260	γϡڤӡϽλΤΤ	for controlling start and/or stop of defrost
F24F  11/41 110 \	4	4	3L260	F24F  11/41	749	٤ѥ᡼Ǥ	by detecting temperature as parameter
F24F  11/41 112 \	5	5	3L260	F24F  11/41	352	äˡ٤ѥ᡼Ǥ	specially, by detecting outdoor air temperature as parameter
F24F  11/41 114 \	5	5	3L260	F24F  11/41	779	äˡǮ򴹴ﲹ٤ѥ᡼Ǥ	specially, by detecting outdoor heat exchanger temperature as parameter
F24F  11/41 120 \	4	4	3L260	F24F  11/41	871	֤ѥ᡼Ǥ	by detecting time as parameter
F24F  11/41 130 \	4	4	3L260	F24F  11/41	53	̤ѥ᡼Ǥ	by detecting air flow  as parameter
F24F  11/41 140 \	4	4	3L260	F24F  11/41	127	ήͤѥ᡼Ǥ	by detecting electric current value as parameter
F24F  11/41 200 \	3	3	3L260	F24F  11/41	423	ƣƣʳԤ	for controlling other than F24F11/41 100
F24F  11/41 210 \	4	4	3L260	F24F  11/41	447	椵ǤǤ	by controlling indoor fan
F24F  11/41 220 \	4	4	3L260	F24F  11/41	425	椵ǤǤ	by controlling outdoor fan
F24F  11/41 230 \	4	4	3L260	F24F  11/41	141	Ǯ郎椵ǤǤ	by cotrolling auxiliary heater
F24F  11/41 240 \	4	4	3L260	F24F  11/41	565	̵椵ǤǤ	by controlling compressor
F24F  11/41 250 \	4	4	3L260	F24F  11/41	560	ۤ椵ǤǤ	by controlling 4-way valve
F24F  11/42  \	3	3	3L260	F24F  11/42	1004	ΡΣ	of outdoor units [2018.01]
F24F  11/43  \	3	3	3L260	F24F  11/43	357	ⵡΡΣ	of indoor units [2018.01]
F24F  11/46  \	2	2	3L260	F24F  11/46	13755	ŵͥ륮θΨޤǽ夵뤳ȡΣ	Improving electric energy efficiency or saving [2018.01]
F24F  11/47  \	3	3	3L260	F24F  11/47	3577	ͥ륮Ȥ˱ΡΣ	Responding to energy costs [2018.01]
F24F  11/48  \	2	2	3L260	F24F  11/48	1419	̾ưΩäƹԤΡ㡥ͽǮޤͽΣ	prior to normal operation, e.g. pre-heating or pre-cooling [2018.01]
F24F  11/49  \	2	2	3L260	F24F  11/49	13860	ưôݡ㡥žޤϷˤΡΣ	ensuring correct operation, e.g. by trial operation or configuration checks [2018.01]
F24F  11/50  \	1	1	3L260	F24F  11/50	2211	桼󥿡եޤ̿ˤħդΡΣ	characterised by user interfaces or communication [2018.01]
F24F  11/52  \	2	2	3L260	F24F  11/52	3507	ɽ֡㡥ǥץ쥤Σ	Indication arrangements, e.g. displays [2018.01]
F24F  11/523  \	3	3	3L260	F24F  11/523	514	٥ǡɽ뤿ΤΡΣ	for displaying temperature data [2018.01]
F24F  11/526  \	3	3	3L260	F24F  11/526	489	ˤɽΡΣ	giving audible indications [2018.01]
F24F  11/54  \	2	2	3L260	F24F  11/54	5379	ʣ֤³룱Ĥ֤ѤΡΣ	using one central controller connected to several sub-controllers [2018.01]
F24F  11/56  \	2	2	3L260	F24F  11/56	2361	Σ	Remote control [2018.01]
F24F  11/57  \	3	3	3L260	F24F  11/57	623	֤ѤΡΣ	using telephone networks [2018.01]
F24F  11/58  \	3	3	3L260	F24F  11/58	3781	󥿡ͥå̿ѤΡΣ	using Internet communication [2018.01]
F24F  11/59  \	3	3	3L260	F24F  11/59	2707	ץ쥻åȤ뤿ΤΡΣ	for presetting [2018.01]
F24F  11/61  \	2	2	3L260	F24F  11/61	12964	ޡѤΡΣ	using timers [2018.01]
F24F  11/62  \	1	1	3L260	F24F  11/62	15603	ޤˤħդΡ㡥եŬޤͤοΣ	characterised by the type of control or by internal processing, e.g. using fuzzy logic, adaptive control or estimation of values [2018.01]
F24F  11/63  \	2	2	3L260	F24F  11/63	1280	ŻŪΣ	Electronic processing [2018.01]
F24F  11/64  \	3	3	3L260	F24F  11/64	19424	¸줿ǡѤΡΣ	using pre-stored data [2018.01]
F24F  11/65  \	3	3	3L260	F24F  11/65	5645	ž⡼ɤ򤹤뤿ΤΡΣ	for selecting an operating mode [2018.01]
F24F  11/66  \	4	4	3L260	F24F  11/66	472	꡼ץ⡼ɡΣ	Sleep mode [2018.01]
F24F  11/67  \	4	4	3L260	F24F  11/67	491	Ǯѥ⡼ɴ֤ڴΣ	Switching between heating and cooling modes [2018.01]
F24F  11/70  \	1	1	3L260	F24F  11/70	11787	Ϥˤħդ楷ƥࡨκ¤Σ	Control systems characterised by their outputs; Constructional details thereof [2018.01]
F24F  11/72  \	2	2	3L260	F24F  11/72	3973	ζ롤㡥ΰϡ椹ΡΣ	for controlling the supply of treated air, e.g. its pressure [2018.01]
F24F  11/74  \	3	3	3L260	F24F  11/74	6440	ή̤ޤή®椹ΡΣ	for controlling air flow rate or air velocity [2018.01]
F24F  11/75  \	4	4	3L260	F24F  11/75	133	ή̤ޤή®˰ݻΡΣ	for maintaining constant air flow rate or air velocity [2018.01]
F24F  11/755  \	4	4	3L260	F24F  11/755	160	ή̤ޤή®μŪѲΤΤΡΣ	for cyclical variation of air flow rate or air velocity [2018.01]
F24F  11/76  \	4	4	3L260	F24F  11/76	2873	٤ȿʤˤΡ㡥Х᥿Ф͡Σ	by means responsive to temperature, e.g. bimetal springs [2018.01]
F24F  11/77  \	4	4	3L260	F24F  11/77	1193	®٤椹ΡΣ	by controlling the speed of ventilators [2018.01]
F24F  11/79  \	3	3	3L260	F24F  11/79	4869	뤵椹ΡΣ	for controlling the direction of the supplied air [2018.01]
F24F  11/80  \	2	2	3L260	F24F  11/80	6360	뤵β٤椹ΡΣ	for controlling the temperature of the supplied air [2018.01]
F24F  11/81  \	3	3	3L260	F24F  11/81	305	Ǯ򴹴ޤϥХѥϩؤζˤΡΣ	by controlling the air supply to heat-exchangers or bypass channels [2018.01]
F24F  11/83  \	3	3	3L260	F24F  11/83	1500	Ǯ򴹴ؤǮήΤζ椹뤳ȤˤΡΣ	by controlling the supply of heat-exchange fluids to heat-exchangers [2018.01]
F24F  11/84  \	4	4	3L260	F24F  11/84	2556	ۤѤΡΣ	using valves [2018.01]
F24F  11/85  \	4	4	3L260	F24F  11/85	599	ή̥ݥפѤΡΣ	using variable-flow pumps [2018.01]
F24F  11/86  \	3	3	3L260	F24F  11/86	10717	ϩޤϥҡȥݥײϩǰ̵椹ΡΣ	by controlling compressors within refrigeration or heat pump circuits [2018.01]
F24F  11/87  \	3	3	3L260	F24F  11/87	365	ˤǮޤǮ椹ΡΣ	by controlling absorption or discharge of heat in outdoor units [2018.01]
F24F  11/871  \	4	4	3L260	F24F  11/871	1120	椹ΡΣ	by controlling outdoor fans [2018.01]
F24F  11/873  \	3	3	3L260	F24F  11/873	1195	ޥҡ椹ΡΣ	by controlling refrigerant heaters [2018.01]
F24F  11/875  \	3	3	3L260	F24F  11/875	1336	Ǯ֤椹ΡΣ	by controlling heat-storage apparatus [2018.01]
F24F  11/88  \	1	1	3L260	F24F  11/88	4836	ŵŪ㡥ϩΣ	Electrical aspects, e.g. circuits [2018.01]
F24F  11/89  \	1	1	3L260	F24F  11/89	15438	ޤϰ֤֤ޤϼդΣ	Arrangement or mounting of control or safety devices [2018.01]
F24F  12/00  \	0	0	3L059	F24F  12/00	86	Ĵ¡ޤϤˤ륨ͥ륮ƥѤΡʵ뵤ӵ֤ǮãӼãʤΣƣƣˡΣ	Use of energy recovery systems in air conditioning, ventilation or screening (with both heat and humidity transfer between supplied and exhausted air F24F 3/147) [4]
F24F  13/00  \	0	0	3L080	F24F  13/00	46	Ĵ¡üޤϤؤΤεήѤ˶̡ޤϤΤκ	Details common to, or for air-conditioning, air-humidification, ventilation or use of air currents for screening
F24F  13/02  \	1	1	3L080	F24F  13/02	14867	Ȥι	Ducting arrangements
F24F  13/02  A	1	0	3L080	F24F  13/02	2312	Ȥι³ȤΩơ㡥	Ducting arrangements, connections or assembly (stringing electric wires)
F24F  13/02  B	1	0	3L080	F24F  13/02	592		Soft ducts
F24F  13/02  C	1	0	3L080	F24F  13/02	1096	¤ʪΰѤȡ㡥ɤޤϾ֤ȤȤѤ	Ducts using a part of buildings
F24F  13/02  D	1	0	3L080	F24F  13/02	1347	ήࡤ㡥ʬ۴	Ducts with air-flow-controlling members including air distributors
F24F  13/02  E	1	0	3L080	F24F  13/02	348	Ȥ¤ʥȤȤΩƣƣƣ	Manufacturing ducts (assembly A)
F24F  13/02  F	1	0	3L080	F24F  13/02	665	Ȥμդ㡥Ȥλٻչ¤ˡ	Mounting ducts (exclusive of soft ducts) (supporting or mounting methods for ducts)
F24F  13/02  G	1	0	3L080	F24F  13/02	308	ȤΥ쥤	Laying out ducts
F24F  13/02  H	1	0	3L080	F24F  13/02	1381	ȤǮɲòɿ	Heat insulation, acoustic insulation or antivibration (noise reduction)
F24F  13/02  Z	1	0	3L080	F24F  13/02	786	¾㡥ݡũɺ	Others (inspection, cleaning, drip prevention or disaster prevention or the like)
F24F  13/04  \	2	2	3L080	F24F  13/04	190	˥åȡʣƣƣͥ	Air-mixing units ()
F24F  13/06  \	2	2	3L080	F24F  13/06	56	ޤ϶֤˶ؤ뤿Τޤʬۤ뤿οи㡥ŷȻ	Outlets for directing or distributing air into rooms or spaces, e.g. ceiling air diffuser
F24F  13/06  A	2	0	3L080	F24F  13/06	1181	иι¤ʣƣƣƣƣͥ	Constructions of outlets (13/062 to 13/078 take precedence)
F24F  13/06  B	2	0	3L080	F24F  13/06	332	иμդʣƣƣƣƣͥ	Mounting of outlets (13/062 to 13/078 take precedence)
F24F  13/06  C	2	0	3L080	F24F  13/06	445	ݥåȶĴѿи	for spot air-conditioning
F24F  13/06  D	2	0	3L080	F24F  13/06	373	иηϪк㳰Ū˶Ĵοиޤ	Measures against condensation on outlets (including outlets of air conditioning apparatus as an exception)
F24F  13/06  E	2	0	3L080	F24F  13/06	242	иǮɲɿ㳰Ū˶Ĵοиޤ	Heat insulation, acoustic insulation or antivibration of outlets (including outlets of air conditioning apparatus as an exception)
F24F  13/06  Z	2	0	3L080	F24F  13/06	435	¾㡥ɿСũɱ褱ݡѥåξʪήɽ㳰Ū˶Ĵοиޤ	Others [prevention of dusts or drops (rain), moth-proofing, inspection, cleaning, small articles such as packing, streamers, deodrisation or the like]  (including outlets of air conditioning apparatus as an exception)
F24F  13/062  \	3	3	3L080	F24F  13/062	527	ή˳ȳ뾯ʤȤ⣱İʾΤޤϱ߿ΤĤΡΣ	having one or more bowls or cones diverging in the flow direction [3]
F24F  13/065  \	3	3	3L080	F24F  13/065	413	žǽʱΤޤϵΤȤƷ줿ΡΣ	formed as cylindrical or spherical bodies which are rotatable [3]
F24F  13/068  \	3	3	3L080	F24F  13/068	50	ΤɡŷޤϾȤƷ줿ΡʣƣƣͥˡΣ	formed as perforated walls, ceilings or floors (F24F 13/078 takes precedence) [3]
F24F  13/068  A	3	0	3L080	F24F  13/068	837	ɡΰȤƷ줿и	Outlets formed as a part of walls or floors
F24F  13/068  B	3	0	3L080	F24F  13/068	735	ŷդиʣƣƣͥ	Outlets mounted in ceilings
F24F  13/068  C	3	0	3L080	F24F  13/068	74	ػҰηи	Outlets Integrated in chairs
F24F  13/068  Z	3	0	3L080	F24F  13/068	35	¾	Others
F24F  13/072  \	3	3	3L080	F24F  13/072	19	ĹΤΡ㡥ŷѥ֤ͥǡΣ	of elongated shape, e.g. between ceiling panels [3]
F24F  13/072  A	3	0	3L080	F24F  13/072	136	ĹиΤȤμȿиζήμľѤǤ	Outlets of elongated shape with axes of ducts and outlet air flows  forming a right angle
F24F  13/072  B	3	0	3L080	F24F  13/072	252	饤ǥե塼	Line diffusers
F24F  13/072  Z	3	0	3L080	F24F  13/072	38	¾	Others
F24F  13/075  \	3	3	3L080	F24F  13/075	162	ήФظʿԤޤġ㡥ΩĴǽޤġĤΡʣƣƣͥˡΣ	having parallel rods or lamellae directing the outflow, e.g. the rods or lamellae being individually adjustable (F24F 13/072 takes precedence) [3]
F24F  13/078  \	3	3	3L080	F24F  13/078	313	˷礵줿ΡΣ	combined with lighting fixtures [3]
F24F  13/08  \	1	1	3L081	F24F  13/08	34	ήࡤ㡥롼СʻҡġʣƣƣƣƣͥˡΣ	Air-flow control members, e.g. louvres, grilles, flaps or guide plates () [3]
F24F  13/08  A	1	0	3L081	F24F  13/08	1805		Fixed control members
F24F  13/08  B	1	0	3L081	F24F  13/08	880	μդ㡥ٻޤϼդ뤿ι¤ޤˡ	Mounting of fixed control members (supports; constructions or methods of mounting to ....)
F24F  13/08  C	1	0	3L081	F24F  13/08	505	ήǻҡ㡥̤Ѥ	Fluid devices (control members using Coanda effect)
F24F  13/08  Z	1	0	3L081	F24F  13/08	77	¾Τ	Others
F24F  13/10  \	2	2	3L081	F24F  13/10	58	ưʤΡ㡥	movable, e.g. dampers
F24F  13/10  A	2	0	3L081	F24F  13/10	847	ưʣƣƣƣƣͥ	Movable control members (13/12 to 13/16 take precedence)
F24F  13/10  B	2	1	3L081	F24F  13/10	275	꡼	Rotary dampers
F24F  13/10  C	2	1	3L081	F24F  13/10	121	ž˼Ф˸ꤵ줿ʣαֿͭޡ	control members having multiple flaps fixed on axes of rotation diagonally [figure]
F24F  13/10  D	2	1	3L081	F24F  13/10	265	ٲžʣƣƣ¡ƣƣáƣƣͥ	Control members being rotatable 360 degrees other than B, C and 14 E
F24F  13/10  E	2	1	3L081	F24F  13/10	494	ľư򤹤	Control members in linear motion
F24F  13/10  Z	2	0	3L081	F24F  13/10	119	¾	Others
F24F  13/12  \	3	3	3L081	F24F  13/12	764	ưफȤΩƤ줿	built-up of sliding members
F24F  13/14  \	3	3	3L081	F24F  13/14	64	ưࡤ㡥롼СȤΩƤ줿	built-up of tilting members, e.g. louvre
F24F  13/14  A	3	0	3L081	F24F  13/14	534	ٻȤư	with rocking frames which supports control members
F24F  13/14  B	3	0	3L081	F24F  13/14	650	ñưʣƣƣġƣƣͥ	Single rocking control member (D and below take precedence)
F24F  13/14  D	3	0	3L081	F24F  13/14	1089	ñưѤΤưüˤΡʣƣƣơƣƣͥ	Single rocking damper with the rocking axis at the edge of damper (F and below take precedence)
F24F  13/14  E	3	0	3L081	F24F  13/14	665	ñưѤΤưüˤʤΡʣƣƣơƣƣͥ	Single rocking damper with the rocking axis being not at the edge of damper (F and below take precedence)
F24F  13/14  F	3	0	3L081	F24F  13/14	575	˼˱ήڤ괹	switching the direction of airflow depending on cooling or heating
F24F  13/14  G	3	0	3L081	F24F  13/14	453	ñưѤ	Operation portion of single rocking damper
F24F  13/14  H	3	0	3L081	F24F  13/14	1005	ư϶ưñư	Power-operated single rocking damper
F24F  13/14  J	3	0	3L081	F24F  13/14	188	ɺñư	Single rocking damper for preventing disaster
F24F  13/14  K	3	1	3L081	F24F  13/14	616	ɺѥѤηߡư߲	Locking or automatic locking-release mechanisms for disaster prevention dampers
F24F  13/14  L	3	2	3L081	F24F  13/14	103	ɺѥѤμư߲Τ˥ԥư	Automatic locking-release mechanisms for disaster prevention dampers, wherein pins are moved in case of emergency
F24F  13/14  Z	3	0	3L081	F24F  13/14	164	¾Τ	Others
F24F  13/15  \	4	4	3L081	F24F  13/15	18	Ʊ˷ưʿԤĤĤΡΣ	with parallel simultaneously tiltable lamellae [3]
F24F  13/15  A	4	0	3L081	F24F  13/15	542	ʣưʣƣƣͥ	Mounting of rocking control members (J takes precedence)
F24F  13/15  B	4	1	3L081	F24F  13/15	2387	¿बˤʤ	with a number of control members arranged in parallel
F24F  13/15  C	4	0	3L081	F24F  13/15	478	ʣưμդ	Attaching multiple rocking control members
F24F  13/15  D	4	0	3L081	F24F  13/15	1371	ư϶ưʣƣƣͥˡ㡥ϥ⥹åȤˤư	Power operated control members exclusive of 14 H) (the power includes shape memory alloys and thermostats)
F24F  13/15  E	4	0	3L081	F24F  13/15	284	ʣư	Multiple rocking dampers
F24F  13/15  F	4	1	3L081	F24F  13/15	303	¿बˤʤ	Dampers with a number of control members arranged in parallel
F24F  13/15  H	4	0	3L081	F24F  13/15	169	ޤ	Dampers foled midways
F24F  13/15  J	4	0	3L081	F24F  13/15	163	ɺʣư	Multiple rocking dampers for disaster prevention
F24F  13/15  Z	4	0	3L081	F24F  13/15	27	¾	Others
F24F  13/16  \	3	3	3L081	F24F  13/16	122	Ū˲ưĤȤΩƤ줿	built-up of parallelly-movable plates
F24F  13/18  \	2	2	3L081	F24F  13/18	39	ʿóʥѥͥ롤㡥ɥޤ勞ˤ褦̤ŬѤ줿ΡΣ	specially adapted for insertion in flat panels, e.g. in door or window-pane[2006.01]
F24F  13/20  \	1	1	3L081	F24F  13/20	10981	󥰤ޤϥСΣ	Casings or covers
F24F  13/20 202 \	2	2	3L081	F24F  13/20	3980	˰̵˥åȤդ	install compressor unit internally
F24F  13/20 205 \	2	2	3L081	F24F  13/20	3122	˴դ	install ventilating fan internally
F24F  13/20 207 \	2	2	3L081	F24F  13/20	2520	Υ֤ĤΡޤ֤򤽤˼դ	having control knob; install control member or control device internally
F24F  13/22  \	1	1	3L081	F24F  13/22	2706	Žɻߤޤ϶ŽʪӽΤμʡΣ	Means for preventing condensation or evacuating condensate
F24F  13/22 221 \	2	2	3L081	F24F  13/22	1545	ŽʪηɻߤΡ㡥Ϫ	preventing condensate from forming, e.g. dew condensation water
F24F  13/22 222 \	2	2	3L081	F24F  13/22	4070	ŽʪӽФ뤿Τ	discharging condensate
F24F  13/22 224 \	2	2	3L081	F24F  13/22	2854	ɥĴΤ	inside window type air conditioning apparatus
F24F  13/22 225 \	2	2	3L081	F24F  13/22	1266	ΤˤŽʪȯΡ㡥Ž̴狼εήˤ	evaporate condensate by coolant, e.g. in air current from condensate
F24F  13/22 227 \	2	2	3L081	F24F  13/22	170	ȯ狼ζŽʪӿΤζŽ̥ѥ	condensation pipe for condensate discharging facility to discharge condensate from evaporator
F24F  13/22 228 \	2	2	3L081	F24F  13/22	125	Žʪν㡥	treatment of condensate, e.g. stelize
F24F  13/24  \	1	1	3L081	F24F  13/24	4295	ɻߤޤΤμʡΣ	means tp prevent or regulate noise
F24F  13/24 242 \	2	2	3L081	F24F  13/24	1298	۲	sound absorbing member
F24F  13/24 245 \	2	2	3L081	F24F  13/24	207	ĤѤ	using sympathetic vibration or resonance
F24F  13/24 247 \	2	2	3L081	F24F  13/24	273	ǽưŪ	active noise control
F24F  13/26  \	1	1	3L081	F24F  13/26	2183	ͶƳʤˤ۴֡㡥ήηޤǮ̤ˤΡΣ	Arrangements for air-circulation by means of induction, e.g. by fluid coupling or thermal effect
F24F  13/28  \	1	1	3L081	F24F  13/28	7852	ե륿֤ޤϼդΣ	Arrangement or mounting of filters
F24F  13/30  \	1	1	3L081	F24F  13/30	5267	Ǯ򴹴֤ޤϼդΣ	Arrangement or mounting of heat-exchangers
F24F  13/32  \	1	1	3L081	F24F  13/32	9374	ĴᡤüޤϴѻٻΣ	Supports for air-conditioning, air-humidification or ventilation units
F24F 110:00  \	0	0		F24F 110/00	1503	˴Ϣ楤ץåȡΣ	Control inputs relating to air properties [2018.01]
F24F 110:10  \	1	1		F24F 110/10	15503	Σ	Temperature [2018.01]
F24F 110:12  \	2	2		F24F 110/12	6458	ΤΡΣ	of the outside air [2018.01]
F24F 110:20  \	1	1		F24F 110/20	4770	١Σ	Humidity [2018.01]
F24F 110:22  \	2	2		F24F 110/22	1787	ΤΡΣ	of the outside air [2018.01]
F24F 110:30  \	1	1		F24F 110/30	2114	®١Σ	Velocity [2018.01]
F24F 110:32  \	2	2		F24F 110/32	122	ΤΡΣ	of the outside air [2018.01]
F24F 110:40  \	1	1		F24F 110/40	537	ϡ㡥Σ	Pressure, e.g. wind pressure [2018.01]
F24F 110:50  \	1	1		F24F 110/50	678	μΣ	Air quality properties [2018.01]
F24F 110:52  \	2	2		F24F 110/52	143	ΤΡΣ	of the outside air [2018.01]
F24F 110:60  \	2	2		F24F 110/60	1254	Σ	Odour [2018.01]
F24F 110:62  \	2	2		F24F 110/62	449	ХαΣ	Tobacco smoke [2018.01]
F24F 110:64  \	2	2		F24F 110/64	765	ͷγҤδ̡ͭΣ	Airborne particle content [2018.01]
F24F 110:65  \	2	2		F24F 110/65	358	ʪޤϱʪǻ١Σ	Concentration of specific substances or contaminants [2018.01]
F24F 110:66  \	3	3		F24F 110/66	75	ȯͭʪΣ֣ϣáϡΣ	Volatile organic compounds [VOC] [2018.01]
F24F 110:68  \	3	3		F24F 110/68	7	ɥΣ	Radon [2018.01]
F24F 110:70  \	3	3		F24F 110/70	226	úǡΣ	Carbon dioxide [2018.01]
F24F 110:72  \	3	3		F24F 110/72	98	úǡΣ	Carbon monoxide [2018.01]
F24F 110:74  \	3	3		F24F 110/74	113	Σ	Ozone [2018.01]
F24F 110:76  \	3	3		F24F 110/76	243	ǡΣ	Oxygen [2018.01]
F24F 110:80  \	2	2		F24F 110/80	224	Ų١Σ	Electric charge [2018.01]
F24F 120:00  \	0	0		F24F 120/00	2060	桼ޤͭԤ˴Ϣ楤ץåȡΣ	Control inputs relating to users or occupants [2018.01]
F24F 120:10  \	1	1		F24F 120/10	1607	ͭΣ	Occupancy [2018.01]
F24F 120:12  \	2	2		F24F 120/12	2638	ͭԤΰ֡Σ	Position of occupants [2018.01]
F24F 120:14  \	2	2		F24F 120/14	1312	ͭԤγưΣ	Activity of occupants [2018.01]
F24F 120:20  \	1	1		F24F 120/20	1531	桼ΥեɥХåΣ	Feedback from users [2018.01]
F24F 130:00  \	0	0		F24F 130/00	274	롼ףƣƣʬवʤĶǤ˴Ϣ楤ץåȡΣ	Control inputs relating to environmental factors not covered by group F24F0110000000 [2018.01]
F24F 130:10  \	1	1		F24F 130/10	610	ݾޤϵͽ¬Σ	Weather information or forecasts [2018.01]
F24F 130:20  \	1	1		F24F 130/20	510	۸Σ	Sunlight [2018.01]
F24F 130:30  \	1	1		F24F 130/30	390	͹Σ	Artificial light [2018.01]
F24F 130:40  \	1	1		F24F 130/40	119	Σ	Noise [2018.01]
F24F 140:00  \	0	0		F24F 140/00	27023	ƥ֤˴Ϣ楤ץåȡΣ	Control inputs relating to system states [2018.01]
F24F 140:10  \	1	1		F24F 140/10	2833	ϡΣ	Pressure [2018.01]
F24F 140:12  \	2	2		F24F 140/12	378	ǮήΰϡΣ	Heat-exchange fluid pressure [2018.01]
F24F 140:20  \	1	1		F24F 140/20	5494	Ǯήβ١Σ	Heat-exchange fluid temperature [2018.01]
F24F 140:30  \	1	1		F24F 140/30	1830	ѶοζŽ̡Σ	Condensation of water from cooled air [2018.01]
F24F 140:40  \	1	1		F24F 140/40	286	Ѱ֡㡥ޤĺΣ	Damper positions, e.g. open or closed [2018.01]
F24F 140:50  \	1	1		F24F 140/50	1389	١Σ	Load [2018.01]
F24F 140:60  \	1	1		F24F 140/60	1663	ͥ륮Σ	Energy consumption [2018.01]
