G01K   1/00  \	0	0	2F056	G01K   1/00	31	ä˲ٷפüʥפŬѤʤٷפκǮѲϩǣˣˡΣ	Details of thermometers not specially adapted for particular types of thermometer (circuits for reducing thermal inertia G01K 7/42) [6]
G01K   1/02  \	1	1	2F056	G01K   1/02	370	ٷפäŬؼޤϵϿʡΣ	Means for indicating or recording specially adapted for thermometers
G01K   1/02  L	1	0	2F056	G01K   1/02	129	Ūʤˤ	By optical means
G01K   1/02  W	1	0	2F056	G01K   1/02	51	岹	Open water temperatures
G01K   1/02  Z	1	0	2F056	G01K   1/02	167	¾Τ	Others
G01K   1/022  \	2	2	2F056	G01K   1/022	381	ϿΤΤΡΣ	for recording
G01K   1/024  \	2	2	2F056	G01K   1/024	821	ֻؼΤΤΡΣ	for remote indication
G01K   1/04  \	2	2	2F056	G01K   1/04	71		Scales
G01K   1/06  \	3	3	2F056	G01K   1/06	154	ɼưפˤ뤿֡㡥	Arrangements for facilitating reading, e.g. illumination, magnifying glass
G01K   1/08  \	1	1	2F056	G01K   1/08	53	ݸ֡㡥󥰡Σ	Protective devices, e.g. casings
G01K   1/08  C	1	0	2F056	G01K   1/08	105	åסС	Sanitary caps or covers
G01K   1/08  L	1	0	2F056	G01K   1/08	88		Cooling
G01K   1/08  N	1	0	2F056	G01K   1/08	363	̤ʹ¤	Special structures
G01K   1/08  P	1	0	2F056	G01K   1/08	807	ⲹݸɡ㡥Ǯ	High-temperature protection tubes, e.g. thermocouples
G01K   1/08  Q	1	0	2F056	G01K   1/08	358	ݸɡ㡥ߥ	Protection tubes, e.g. thermistors
G01K   1/08  R	1	0	2F056	G01K   1/08	174	ݸɡ㡥饹ٷפ¾	Protection tubes, e.g. glass thermometers
G01K   1/08  Z	1	0	2F056	G01K   1/08	314	¾Τ	Others
G01K   1/10  \	2	2	2F056	G01K   1/10	40	Ūɤ	for preventing chemical attack
G01K   1/12  \	2	2	2F056	G01K   1/12	36	Ǯˤ»ɤ	for preventing damage due to heat overloading
G01K   1/14  \	1	1	2F056	G01K   1/14	228	ٻʪ֡ξ˲ٷפ夹뤿ι¤Σ	Supports; Fastening devices; Arrangements for mounting thermometers in particular locations
G01K   1/14  B	1	0	2F056	G01K   1/14	575	ɤФƲٷפ̻ٻ	Supporting thermometers by piercing through the wall
G01K   1/14  E	1	0	2F056	G01K   1/14	1122	ٷפλٻ	Supporting or putting on thermometers
G01K   1/14  G	1	0	2F056	G01K   1/14	195	Ҿ׷¬ץ֤æ뿻	Mounting or dismounting of immersion-wear-out temperature measurement probes, feed immersion devices
G01K   1/14  H	1	0	2F056	G01K   1/14	161	ϧɸ	Fixed on furnace walls
G01K   1/14  J	1	0	2F056	G01K   1/14	127	ϧɴ	Inserting device by piercing through furnace walls
G01K   1/14  K	1	0	2F056	G01K   1/14	96	ϧ¬	Measuring furnace gas temperatures
G01K   1/14  L	1	0	2F056	G01K   1/14	2794	оݤؤβٷפ	Mounting thermometers on particular objects
G01K   1/14  M	1	0	2F056	G01K   1/14	178	¬	Measuring baring temperatures
G01K   1/14  N	1	0	2F056	G01K   1/14	101	̱ղ	Thermometers for measuring liquid surface temperatures
G01K   1/14  P	1	0	2F056	G01K   1/14	57	¿ե	Multiple fins
G01K   1/14  Q	1	0	2F056	G01K   1/14	141	եȡ߲	Floats, hanging, hooking
G01K   1/14  R	1	0	2F056	G01K   1/14	39	Ź¤	Double structures
G01K   1/14  Z	1	0	2F056	G01K   1/14	163	¾Τ	Others
G01K   1/143  \	2	2	2F056	G01K   1/143	1243	ɽ̲٤¬ꤹ뤿ΤΡΣ	for measuring surface temperatures
G01K   1/16  \	1	1	2F056	G01K   1/16	834	оʪ鴶ǻҤǮƳӤ̤ʵ	Special arrangements for conducting heat from the object to the sensitive element
G01K   1/18  \	2	2	2F056	G01K   1/18	149	Ǯ򸺤	for reducing thermal inertia
G01K   1/20  \	1	1	2F056	G01K   1/20	195	¬оݰʳβѲ㡥ϲѲαƶ	Compensating for effects of temperature changes other than those to be measured, e.g. changes in ambient temperature
G01K   1/22  \	2	2	2F056	G01K   1/22	5	ήΤˤäϤѷޤѰ̤Τ줿Τˤ	by means of fluid contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the fluid
G01K   1/24  \	2	2	2F056	G01K   1/24	6	ҤޤĤʣΡ㡥Х᥿ҡˤ	by means of compounded strips or plates, e.g. bimetallic strips
G01K   1/26  \	1	1	2F056	G01K   1/26	7	Ѳαƶ	Compensating for effects of pressure changes
G01K   3/00  \	0	0	2F056	G01K   3/00	229	٤νֻͰʳη̤򼨤ٷסʣǣˣͥˡΣ	Thermometers giving results other than momentary value of temperature () [6]
G01K   3/02  \	1	1	2F056	G01K   3/02	24	ʿͤͿΡѻͤͿ	giving mean values; giving integrated values
G01K   3/02  M	1	0	2F056	G01K   3/02	160	ʿͤͿ	Giving mean values
G01K   3/02  S	1	0	2F056	G01K   3/02	102	ѻͤͿ	Giving integrated values
G01K   3/02  Z	1	0	2F056	G01K   3/02	18	¾Τ	Others
G01K   3/04  \	2	2	2F056	G01K   3/04	79	֤˴ؤ	in respect of time
G01K   3/06  \	2	2	2F056	G01K   3/06	77	֤˴ؤ	in respect of space
G01K   3/08  \	1	1	2F056	G01K   3/08	132	ͤͿΡʬͤͿ	giving differences of values; giving differentiated values
G01K   3/10  \	2	2	2F056	G01K   3/10	159	֤˴ؤΡ㡥٤εѤˤΤȿ	in respect of time, e.g. reacting only to a quick change of temperature
G01K   3/12  \	3	3	2F056	G01K   3/12	7	ʪĥ̤äȤ	based upon expansion or contraction of materials
G01K   3/14  \	2	2	2F056	G01K   3/14	132	֤˴ؤ	in respect of space
G01K   5/00  \	0	0	2F056	G01K   5/00	70	ʪĥ̤˴Ť¬ʣǣˣͥ表٤νֻͰʳη̤򼨤Σǣˣ	Measuring temperature based on the expansion or contraction of a material (; giving other than momentary value of temperature G01K 3/00)
G01K   5/02  \	1	1	2F056	G01K   5/02	189	ʪΤǤΡʣǣˣͥ	the material being a liquid ()
G01K   5/02  A	1	0	2F056	G01K   5/02	198	¾ʪʤȹޤ줿	Assembled in other articles
G01K   5/02  Z	1	0	2F056	G01K   5/02	329	¾Τ	Others
G01K   5/04  \	2	2	2F056	G01K   5/04	99		Details
G01K   5/06  \	3	3	2F056	G01K   5/06	98	򲡤	Arrangements for driving back the liquid column
G01K   5/08  \	3	3	2F056	G01K   5/08	75	Ӻٴ	Capillary tubes
G01K   5/10  \	3	3	2F056	G01K   5/10	8	ƴ	Containers for the liquid
G01K   5/12  \	3	3	2F056	G01K   5/12	9	ʬ	Selection of liquid compositions
G01K   5/14  \	2	2	2F056	G01K   5/14	13	Τ¾αޤϸΤѰ̤ΡʺޤϺǾؼΣǣˣ	the liquid displacing a further liquid column or a solid body (for maximum or minimum indication G01K 5/20)
G01K   5/16  \	2	2	2F056	G01K   5/16	116	ŵĤ	with electric contacts
G01K   5/18  \	2	2	2F056	G01K   5/18	76	ǽؼΤŵ̤ѴʤĤ	with electric conversion means for final indication
G01K   5/20  \	2	2	2F056	G01K   5/20	27	ǾޤϤξؼʤĤΡʣǣˣͥ	with means for indicating a maximum or a minimum or both (G01K 5/22 takes precedence)
G01K   5/22  \	2	2	2F056	G01K   5/22	137	٤ۤʤϰϤˤ錄礷ƻؼ뵡ĤΡΣ	with provision for expansion indicating over not more than a few degrees
G01K   5/24  \	2	2	2F056	G01K   5/24	7	ٴ֤κ¬ꤹ뤿εĤ	with provision for measuring the difference between two temperatures
G01K   5/26  \	2	2	2F056	G01K   5/26	0	Ĵ뤿εĤΡ㡥٥åޥٷ	with provision for adjusting zero point of scale, e.g. Beckmann thermometer
G01K   5/28  \	1	1	2F056	G01K   5/28	68	ʪǤΡʣǣˣͥ	the material being a gas ()
G01K   5/30  \	2	2	2F056	G01K   5/30	1	Ѱ̤	the gas displacing a liquid column
G01K   5/32  \	1	1	2F056	G01K   5/32	194	ʪˤäϤѷޤѰ̤ΤήưʪʾȯˤȯϤˤΣǣˣ	the material being a fluid contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the material (under pressure developed by evaporation G01K 11/04)
G01K   5/34  \	2	2	2F056	G01K   5/34	4	बץǤΡʣǣˣǣˣͥ	the body being a capsule (G01K 5/36, G01K 5/42 take precedence)
G01K   5/36  \	2	2	2F056	G01K   5/36	62	बɾΤǤΡ㡥֥ɥ	the body being a tubular spring, e.g. Bourdon tube
G01K   5/38  \	3	3	2F056	G01K   5/38	61	¤Τ	of spiral formation
G01K   5/40  \	3	3	2F056	G01K   5/40	1	¤Τ	of helical formation
G01K   5/42  \	2	2	2F056	G01K   5/42	75	ब٥Ǥ	the body being a bellows
G01K   5/44  \	2	2	2F056	G01K   5/44	184	बȥԥȥ󤫤ʤ	the body being a cylinder and piston
G01K   5/46  \	2	2	2F056	G01K   5/46	11	ǽؼΤŵ̤ѴʤĤ	with electric conversion means for final indication
G01K   5/48  \	1	1	2F056	G01K   5/48	223	ʪΤǤ	the material being a solid
G01K   5/50  \	2	2	2F056	G01K   5/50	31	ͳıޤϼ̤Ǥ	arranged for free expansion or contraction
G01K   5/52  \	3	3	2F056	G01K   5/52	48	ǽؼΤŵ̤ѴʤĤ	with electrical conversion means for final indication
G01K   5/54  \	2	2	2F056	G01K   5/54	0	ԥܥå³줿ǻҤʤ	consisting of pivotally-connected elements
G01K   5/56  \	2	2	2F056	G01K   5/56	19	ıޤϼ̤Τѷ褦˹«	constrained so that expansion or contraction causes a deformation of the solid
G01K   5/58  \	3	3	2F056	G01K   5/58	12	Τʾǹ«ƤΡ㡥塤ġեʣǣˣͥ	the solid body being constrained at more than one point, e.g. rod, plate, diaphragm (G01K 5/62 takes precedence)
G01K   5/60  \	4	4	2F056	G01K   5/60	16	बޤҤǤ	the body being a flexible wire or ribbon
G01K   5/62  \	3	3	2F056	G01K   5/62	562	ΤʣҤޤʣġ㡥Х᥿ҤƤ	the solid body being formed of compounded strips or plates, e.g. bimetallic strip
G01K   5/64  \	4	4	2F056	G01K   5/64	48	ʣϤκ	Details of the compound system
G01K   5/66  \	5	5	2F056	G01K   5/66	8	ϤιǤ۹	Selection of composition of the components of the system
G01K   5/68  \	5	5	2F056	G01K   5/68	13	Ϥη	Shape of the system
G01K   5/70  \	4	4	2F056	G01K   5/70	32	ؼޤϵϿäŬ礹	specially adapted for indicating or recording
G01K   5/72  \	5	5	2F056	G01K   5/72	161	ǽؼΤŵŪʤĤ	with electric transmission means for final indication
G01K   7/00  \	0	0	2F056	G01K   7/00	187	ǮľܴŵŪޤϼŪǻҤλѤäȤ¬ʲ٤νֻͰʳη̤򼨤Σǣˣ	Measuring temperature based on the use of electric or magnetic elements directly sensitive to heat (giving results other than momentary value of temperature G01K 3/00)
G01K   7/00  A	0	0	2F056	G01K   7/00	659	٥󥵤νüüȢƳȤ³	Connecting to output terminals of temperature sensors, terminal boxes or conductors
G01K   7/00  J	0	0	2F056	G01K   7/00	340	ȲǮ֤ȹޤ	Assembled in high-frequency heaters
G01K   7/00  K	0	0	2F056	G01K   7/00	182	ٸ	For detecting coil temperatures
G01K   7/00  M	0	0	2F056	G01K   7/00	53	ꥹȤٷ	Thermometers using of thyristors
G01K   7/00  N	0	0	2F056	G01K   7/00	88	ǻҤȤٷ	Thermometers using pyro elements
G01K   7/00  Z	0	0	2F056	G01K   7/00	283	¾Τ	Others
G01K   7/00 301 \	1	1	2F056	G01K   7/00	5	ٷפɽ	Indicating units of thermometers
G01K   7/00 301 D	1	0	2F056	G01K   7/00	126	ɽɽι¤	Structures of indicators or indicating units
G01K   7/00 301 G	1	0	2F056	G01K   7/00	83	¬ͤñɽ	Simple indication of measured temperature values
G01K   7/00 301 M	1	0	2F056	G01K   7/00	131	ͤȤӷ̡¿νֻ	Comparison results with settings, momentary values at multiple points
G01K   7/00 301 Z	1	0	2F056	G01K   7/00	242	¾Τ	Others
G01K   7/00 311 \	1	1	2F056	G01K   7/00	223	ٷפη	Alarm units for thermometers
G01K   7/00 321 \	1	1	2F056	G01K   7/00	5	¬ϩ	Temperature measurement circuits
G01K   7/00 321 C	1	0	2F056	G01K   7/00	246	ʤͭ	With correction or calibration means
G01K   7/00 321 G	1	0	2F056	G01K   7/00	144	ϼʡѴ	Inputting means, AD conversions
G01K   7/00 321 M	1	0	2F056	G01K   7/00	68	¬ͤεʤͭ	With means for memorising measured values
G01K   7/00 321 J	1	0	2F056	G01K   7/00	249	ͤȤӡȽʤͭ	With means for comparing with settings or determining
G01K   7/00 321 Z	1	0	2F056	G01K   7/00	233	¾Τ	Others
G01K   7/00 381 \	1	1	2F056	G01K   7/00	4	¬ˡ	Measuring methods of temperatures
G01K   7/00 381 D	1	0	2F056	G01K   7/00	200	ʬ͡в֤򻻽ФǤȤ	Using of differentiated values or elapsed time as the calculating element
G01K   7/00 381 G	1	0	2F056	G01K   7/00	194	ʬ͡в֤򻻽ФǤȤʤ	Not using of differentiated values or elapsed time as the calculating element
G01K   7/00 381 L	1	0	2F056	G01K   7/00	345	̤оݤŬѤ	Applied to special objects
G01K   7/00 381 Z	1	0	2F056	G01K   7/00	61	¾Τ	Others
G01K   7/01  \	1	1	2F056	G01K   7/01	0	УܹȾƳǻҤѤΡʣǣˣǣˣǣˣͥˡΣ	using semiconducting elements having PN junctions (G01K  7/02, G01K  7/16, G01K  7/30 take precedence);;
G01K   7/01  C	1	0	2F056	G01K   7/01	667	ϩ	absorptance type
G01K   7/01  L	1	0	2F056	G01K   7/01	27	ȯǻҤȤ	reflection type
G01K   7/01  M	1	0	2F056	G01K   7/01	160	ͣϣӡƣţԤȤ	using MOS, FET
G01K   7/01  S	1	0	2F056	G01K   7/01	158	¤	structure
G01K   7/01  Z	1	0	2F056	G01K   7/01	101	¾Τ	Others
G01K   7/02  \	1	1	2F056	G01K   7/02	119	ǮǻҤˤΡ㡥ǮСΣ	using thermoelectric elements, e.g. thermocouples
G01K   7/02  A	1	0	2F056	G01K   7/02	1082	ǮФκ¤	Materials or structures of thermocouples
G01K   7/02  B	1	0	2F056	G01K   7/02	97	Ƴ	Compensating conductors
G01K   7/02  C	1	0	2F056	G01K   7/02	1288	ݸɤ˼Ǽ줿Ǯ	Thermocouples accommodated in protection tube
G01K   7/02  E	1	0	2F056	G01K   7/02	414	¿ʬ	Multi-points, distributions
G01K   7/02  F	1	0	2F056	G01K   7/02	134	б	For flames
G01K   7/02  G	1	0	2F056	G01K   7/02	59	ǮСܥ꡼ɥ졼	Thermocouples + lead relays
G01K   7/02  L	1	0	2F056	G01K   7/02	435	¬ϩ	Temperature measuring circuits
G01K   7/02  Q	1	0	2F056	G01K   7/02	259	ɽܿ㡥ư	Surface contact type, e.g. moving objects
G01K   7/02  R	1	0	2F056	G01K   7/02	202	Ҿ׷Ǯ	Immersion-wear-out type thermocouples
G01K   7/02  S	1	0	2F056	G01K   7/02	129	ץ󥰼տ魯	Accompanying sampling chambres
G01K   7/02  Z	1	0	2F056	G01K   7/02	552	¾Τ	Others
G01K   7/026  \	2	2	2F056	G01K   7/026	218	ǮФθξޤΤ뤿֡Σ	Arrangements for signalling failure or disconnection of thermocouples
G01K   7/04  \	2	2	2F056	G01K   7/04	5	¬оʪǮʪΰʤΡΣ	the object to be measured not forming one of the thermoelectric materials
G01K   7/06  \	3	3	2F056	G01K   7/06	9	ǻҤ¾ǻҤ֤졢üˤܹоʪˤ餵ƤǮʪ㡥䷿Σ	the thermoelectric materials being arranged one within the other with the junction at one end exposed to the object, e.g. sheathed type
G01K   7/08  \	2	2	2F056	G01K   7/08	38	¬оʪǮʪΰΡ㡥ؼΣ	the object to be measured forming one of the thermoelectric materials, e.g. pointed type
G01K   7/10  \	2	2	2F056	G01K   7/10	5	ѿ㡥ƳĹФ	Arrangements for compensating for auxiliary variables, e.g. length of lead
G01K   7/12  \	3	3	2F056	G01K   7/12	25	˴ؤ뵡㡥Ϥ絤٤αƶɻߤ	Arrangements with respect to the cold junction, e.g. preventing influence of temperature of surrounding air
G01K   7/12  A	3	0	2F056	G01K   7/12	221	üҡü	Cold contact terminals, terminal plates
G01K   7/12  Z	3	0	2F056	G01K   7/12	52	¾Τ	Others
G01K   7/13  \	4	4	2F056	G01K   7/13	215	ѲϩΣ	Circuits for cold-junction compensation
G01K   7/14  \	2	2	2F056	G01K   7/14	97	뵡㡥ˤ	Arrangements for modifying the output characteristic, e.g. linearising
G01K   7/16  \	1	1	2F056	G01K   7/16	88	ǻҤȤ	using resistive elements
G01K   7/16  A	1	0	2F056	G01K   7/16	173	֥ǻҤȤ	Using of cable resistance elements
G01K   7/16  B	1	0	2F056	G01K   7/16	146	̾ǻҤȤ	Using of surface resistance elements
G01K   7/16  C	1	0	2F056	G01K   7/16	131	٥󥵤տ魯	Accompanying humidity sensors
G01K   7/16  M	1	0	2F056	G01K   7/16	181	¿ʬ	Multi-points, distributions
G01K   7/16  S	1	0	2F056	G01K   7/16	305	񹳺	Temperature sensitive resistance materials
G01K   7/16  Z	1	0	2F056	G01K   7/16	332	¾Τ	Others
G01K   7/18  \	2	2	2F056	G01K   7/18	38	ǻҤΤǤΡ㡥񹳲ٷסʣǣˣͥ	the element being a linear resistance, e.g. platinum resistance thermometer (G01K 7/26 takes precedence)
G01K   7/18  A	2	0	2F056	G01K   7/18	526	¬ΤȤ	Using of temperature measuring resistors
G01K   7/18  B	2	0	2F056	G01K   7/18	449	ǻҤȤ	Using of thin film resistance elements
G01K   7/18  Z	2	0	2F056	G01K   7/18	57	¾Τ	Others
G01K   7/20  \	3	3	2F056	G01K   7/20	38	äŬ礹ϩ㡥֥åϩˤ	in a specially-adapted circuit, e.g. bridge circuit
G01K   7/20  A	3	0	2F056	G01K   7/20	298	¬Ρ㡥ߥǤΡʣͥ	Three-wire temperature measuring resistors e.g. thermistors (7/26 takes precedence.)
G01K   7/20  Z	3	0	2F056	G01K   7/20	237	¾Τ	Others
G01K   7/21  \	4	4	2F056	G01K   7/21	5	뤿ΤΡ㡥ˤΡΣ	for modifying the output characteristic, e.g. linearising
G01K   7/22  \	2	2	2F056	G01K   7/22	132	ǻҤΡ㡥ߥǤΡʣǣˣͥ	the element being a non-linear resistance, e.g. thermistor (G01K 7/26 takes precedence)
G01K   7/22  A	2	0	2F056	G01K   7/22	398	ǻҤȤ	Using of thin film resistance elements
G01K   7/22  C	2	0	2F056	G01K   7/22	871	ݸɤĤ	With protection tubes
G01K   7/22  D	2	1	2F056	G01K   7/22	273	ⲹ¬	For measuring high temperatures
G01K   7/22  F	2	1	2F056	G01K   7/22	254	ե󥸤ȥͥͭ	With flanges or screws
G01K   7/22  J	2	0	2F056	G01K   7/22	591	ٻչ¤ͭ	With supporting or mounting structures
G01K   7/22  L	2	0	2F056	G01K   7/22	675	Ƴޤ๽¤	Structures including conductors
G01K   7/22  N	2	0	2F056	G01K   7/22	418	ǻҹ¤	Element structures
G01K   7/22  Q	2	0	2F056	G01K   7/22	302	ɽܿ㡥ư	Surface contact type, e.g. moving objects
G01K   7/22  W	2	0	2F056	G01K   7/22	234	Ϥ岹	Bath temperatures
G01K   7/22  Z	2	0	2F056	G01K   7/22	328	¾Τ	Others
G01K   7/24  \	3	3	2F056	G01K   7/24	150	äŬ礹ϩ㡥֥åϩˤ	in a specially-adapted circuit, e.g. bridge circuit
G01K   7/24  A	3	0	2F056	G01K   7/24	526	ʥϩ	Analogue circuits
G01K   7/24  D	3	0	2F056	G01K   7/24	169	ǥϩ	Digital circuits
G01K   7/24  F	3	0	2F056	G01K   7/24	287	٢ȿ	Temperature R periods, frequencies
G01K   7/24  G	3	0	2F056	G01K   7/24	468	겹Ķḡβϩ	Circuits detecting when a preset temperature is exceeded
G01K   7/24  M	3	0	2F056	G01K   7/24	292	ξ㡤βϩ	Failure or open wire detecting circuits
G01K   7/24  Z	3	0	2F056	G01K   7/24	107	¾Τ	Others
G01K   7/25  \	4	4	2F056	G01K   7/25	1	뤿ΤΡ㡥ˤΡΣ	for modifying the output characteristic, e.g. linearising
G01K   7/25  A	4	0	2F056	G01K   7/25	284	ʥϩ	analogue circuit
G01K   7/25  D	4	0	2F056	G01K   7/25	95	ǥϩ	digital circuit
G01K   7/25  F	4	0	2F056	G01K   7/25	124	٢ȿ	temperatre &rarr; period, frequency
G01K   7/25  Z	4	0	2F056	G01K   7/25	7	¾Τ	Others
G01K   7/26  \	2	2	2F056	G01K   7/26	25	ǻҤŲǤ	the element being an electrolyte
G01K   7/28  \	3	3	2F056	G01K   7/28	0	äŬ礹ϩ㡥֥åϩˤ	in a specially-adapted circuit, e.g. bridge circuit
G01K   7/30  \	1	1	2F056	G01K   7/30	27	ΤޤƳΤǮѤ	using thermal noise of resistances or conductors
G01K   7/32  \	1	1	2F056	G01K   7/32	67	뾽ζȿѲѤ	using change of resonant frequency of a crystal
G01K   7/32  C	1	0	2F056	G01K   7/32	48	徽ٷ	Quartz thermometers
G01K   7/32  D	1	1	2F056	G01K   7/32	99	¤	Structures
G01K   7/32  E	1	1	2F056	G01K   7/32	146	ϩ	Circuits
G01K   7/32  N	1	0	2F056	G01K   7/32	40	ΣѣҲٷ	NQR thermometers
G01K   7/32  S	1	0	2F056	G01K   7/32	141	ӣײٷ	SAW thermometers
G01K   7/32  Z	1	0	2F056	G01K   7/32	115	¾Τ	Others
G01K   7/34  \	1	1	2F056	G01K   7/34	216	ǻҤȤ	using capacitative elements
G01K   7/36  \	1	1	2F056	G01K   7/36	47	ǻҡ㡥С롤Ȥ	using magnetic elements, e.g. magnets, coils
G01K   7/36  A	1	0	2F056	G01K   7/36	285	̤ѲȤƸФ	Detecting as changes in L
G01K   7/36  B	1	0	2F056	G01K   7/36	421	ʵ׼Фȴե饤ȤȤ߹碌	Combinations of permanent magnets and temperature sensing ferrite
G01K   7/36  Z	1	0	2F056	G01K   7/36	125	¾Τ	Others
G01K   7/38  \	2	2	2F056	G01K   7/38	41	ѲƩΨ˱ƶ	the variations of temperature influencing the magnetic permeability
G01K   7/40  \	1	1	2F056	G01K   7/40	1	Υ󲽤Ѥ	using ionisation of gases
G01K   7/42  \	1	1	2F056	G01K   7/42	4	Ǯ»ܤϩ٤ͤͽ¬뤿βϩΣ	Circuits effecting compensation of thermal inertia; Circuits for predicting the stationary value of a temperature
G01K   7/42  A	1	0	2F056	G01K   7/42	134	βפ˴ؤ	thermometer
G01K   7/42  Z	1	0	2F056	G01K   7/42	14	¾Τ	Others
G01K   9/00  \	0	0	2F056	G01K   9/00	4	̤κʬˤäư˴Ť¬ꡤ㡥вٷסʲ٤νֻͤͿʤΣǣˣ	Measuring temperature based on movements caused by redistribution of weight, e.g. tilting thermometer (not giving momentary value of temperature G01K 3/00)
G01K  11/00  \	0	0	2F056	G01K  11/00	108	롼ףǣˣǣˣǣˣޤϣǣˣޤʤʪŪޤϲŪѲ˴Ť¬	Measuring temperature based on physical or chemical changes not covered by group G01K 3/00, G01K 5/00, G01K 7/00, or G01K 9/00
G01K  11/00  M	0	0	2F056	G01K  11/00	371	Ѥ	Using of shape memory alloys
G01K  11/00  Z	0	0	2F056	G01K  11/00	402	¾Τ	Others
G01K  11/02  \	1	1	2F056	G01K  11/02	48	ޤϾڤѤΡ㡥ʨƭδѻˤ	using evaporation or sublimation, e.g. by observing boiling
G01K  11/04  \	2	2	2F056	G01K  11/04	35	ˤäϤѷޤѰ̤ΤäƤʪʤ	from material contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the vapour
G01K  11/06  \	1	1	2F056	G01K  11/06	38	ϲɹ롤𲽤Ѥ	using melting, freezing, or softening
G01K  11/06  A	1	0	2F056	G01K  11/06	21	β	For clinical thermometers
G01K  11/06  B	1	0	2F056	G01K  11/06	211	ŵŪûϩ	Creating electrical shorting or open circuits
G01K  11/06  C	1	0	2F056	G01K  11/06	391	Ǯ򡤲ม	For detecting thermal history or thawing
G01K  11/06  Z	1	0	2F056	G01K  11/06	309	¾Τ	Others
G01K  11/08  \	2	2	2F056	G01K  11/08	5	ʬǤΤ˴ؤΡ㡥륳	of disposable test bodies, e.g. cone
G01K  11/10  \	1	1	2F056	G01K  11/10	2	ƷѤ	using sintering
G01K  11/12  \	1	1	2F056	G01K  11/12	108	Ʃ٤ޤȿΨѲѤΡΣ	using changes in colour, translucency or reflectance
G01K  11/12  A	1	0	2F056	G01K  11/12	928	ܻ뷿	Visual types
G01K  11/12  B	1	0	2F056	G01K  11/12	112	мʤͭΡȿΨѲѤΤ	With detecting means except for those using change in reflectance
G01K  11/12  D	1	1	2F056	G01K  11/12	285	Ʃ᷿	Transmitting types
G01K  11/12  E	1	2	2F056	G01K  11/12	112	ưΤˤϩ	Shutting off optical passages with moving objects
G01K  11/12  H	1	2	2F056	G01K  11/12	565	󥵤θŪѲ	Changes in optical characteristics of sensors
G01K  11/12  L	1	0	2F056	G01K  11/12	494	¾ʪʤȹޤ줿	Assembled in other articles
G01K  11/12  Z	1	0	2F056	G01K  11/12	73	¾Τ	Others
G01K  11/125  \	2	2	2F056	G01K  11/125	333	ȿΨѲѤΡΣ	using changes in reflectance
G01K  11/14  \	2	2	2F056	G01K  11/14	47	̵ʪ˴ؤ	of inorganic materials
G01K  11/16  \	2	2	2F056	G01K  11/16	194	ͭʪ˴ؤΡΣ	of organic materials
G01K  11/165  \	3	3	2F056	G01K  11/165	85	ͭվ˴ؤΡΣ	of organic liquid crystals
G01K  11/18  \	2	2	2F056	G01K  11/18	44	Ʃ٤Ѳʪ˴ؤ	of materials which change translucency
G01K  11/20  \	1	1	2F056	G01K  11/20	255	ǮȯʪѤΡʣǣˣͥˡΣ	using thermoluminescent materials
G01K  11/22  \	1	1	2F056	G01K  11/22	211	̤¬Ѥ	using measurement of acoustic effects
G01K  11/24  \	2	2	2F056	G01K  11/24	296	®٤ˤ	of the velocity of propagation of sound
G01K  11/26  \	2	2	2F056	G01K  11/26	37	ȿˤ	of resonant frequencies
G01K  11/28  \	1	1	2F056	G01K  11/28	6	̩٤¬Ѥ	using measurements of density
G01K  11/30  \	1	1	2F056	G01K  11/30	39	γʪ˵ڤܤ̤¬ѤΡΣ	using measurement of the effect of a material on X-radiation, gamma radiation or particle radiation [5]
G01K  11/32  \	1	1	2F056	G01K  11/32	7	եСˤƩΨޤȯѲѤΡΣ	using changes in transmittance, scattering or luminescence in optical fibres
G01K  11/32  A	1	0	2F056	G01K  11/32	334	ޥ𡤥֥륢˸ꤵʤѤ	Raman scattering, using scattered light not restricted to Brillouin scattering
G01K  11/32  E	1	0	2F056	G01K  11/32	11	ָեФѤ	using fluorescence fiber
G01K  11/32  Z	1	0	2F056	G01K  11/32	223	¾Τ	Others
G01K  11/3206  \	2	2	2F056	G01K  11/3206	225	եСΥ֤ˤΡ㡥֥åѤΡΣ	at discrete locations in the fibre, e.g. using Bragg scattering
G01K  11/3213  \	3	3	2F056	G01K  11/3213	3	ȯѲѤΡ㡥եСüȯѲѤΡΣ	using changes in luminescence, e.g. at the distal end of the fibres
G01K  11/322  \	2	2	2F056	G01K  11/322	126	֥륢ѤΡΣ	using Brillouin scattering
G01K  11/324  \	2	2	2F056	G01K  11/324	516	ޥѤΡΣ	using Raman scattering
G01K  13/00  \	0	0	2F056	G01K  13/00	693	ŪäŬٷסΣ	Thermometers specially adapted for specific purposes
G01K  13/02  \	1	1	2F056	G01K  13/02	1255	ưƤήΤޤήưǽγΤβ٤¬ꤹ뤿ΤΡΣ	for measuring temperature of moving fluids or granular materials capable of flow
G01K  13/024  \	2	2	2F056	G01K  13/024	622	ήư뵤Τβ٤¬ꤹ뤿ΤΡΣ	of moving gases
G01K  13/04  \	1	1	2F056	G01K  13/04	27	ưΤβ٤¬ꤹ	for measuring temperature of moving solid bodies
G01K  13/04  B	1	0	2F056	G01K  13/04	17	Ǯʿշ	Thermal equilibrium types
G01K  13/04  Z	1	0	2F056	G01K  13/04	127	¾Τ	Others
G01K  13/06  \	2	2	2F056	G01K  13/06	110	ľưΤ	in linear movement
G01K  13/08  \	2	2	2F056	G01K  13/08	61	žưΤ	in rotary movement
G01K  13/08  A	2	0	2F056	G01K  13/08	258	žξΥ󥵤Ѥ	Using of sensors mounted on rotating objects
G01K  13/08  B	2	0	2F056	G01K  13/08	450	Ż߻ٻΥ󥵤Ѥ	Using of sensor mounted on static objects
G01K  13/08  Z	2	0	2F056	G01K  13/08	33	¾Τ	Others
G01K  13/10  \	1	1	2F056	G01K  13/10	128	ʪ٤¬ꤹΡоʪ鴶ǻҤǮƳӤ̤ʵˤΣǣˣ	for measuring temperature within piled or stacked materials (by special arrangements for conducting heat from the object to the sensitive element G01K 1/16)
G01K  13/12  \	1	1	2F056	G01K  13/12	129	β٤¬ꤹ뤿˥ץ֤ȷ礷	combined with sampling devices for measuring temperatures of samples of material
G01K  13/20  \	1	1	2F056	G01K  13/20	240	ͤޤưʪѤ롤ܿβסΣ	Clinical contact thermometers for use with humans or animals
G01K  13/20 331 \	2	2	2F056	G01K  13/20	34	Żβ	Electronic thermometers
G01K  13/20 341 \	3	3	2F056	G01K  13/20	11	°	Details, accessories
G01K  13/20 341 D	3	0	2F056	G01K  13/20	205	ʬΥ¤	Detached construction
G01K  13/20 341 G	3	0	2F056	G01K  13/20	426	η¤	Integrated construction
G01K  13/20 341 P	3	0	2F056	G01K  13/20	328	ץ	Temperature-sensitive probe
G01K  13/20 341 Z	3	0	2F056	G01K  13/20	255	¾Τ	Others
G01K  13/20 351 \	3	3	2F056	G01K  13/20	60	ʥ	Analogue
G01K  13/20 361 \	3	3	2F056	G01K  13/20	4	ǥ뼰	Digital
G01K  13/20 361 C	3	0	2F056	G01K  13/20	124	ʤͭ	With means to make corrections and calibration
G01K  13/20 361 D	3	0	2F056	G01K  13/20	161	¬̤ɽ	Indicating the results of temperature measurement
G01K  13/20 361 E	3	0	2F056	G01K  13/20	124	¬в桤λɽ	Indicating the end of measurement or the status where in the measurement is under process
G01K  13/20 361 F	3	0	2F056	G01K  13/20	166	β¬	For measurement of basic body temperature
G01K  13/20 361 G	3	0	2F056	G01K  13/20	111	ϩ	Circuits
G01K  13/20 361 H	3	0	2F056	G01K  13/20	54	ͽǮǮ	Preheating, heating
G01K  13/20 361 K	3	0	2F056	G01K  13/20	167	¬͡ͽ¬ڴ	Change of the indication from measured values to predicted values, and vice versa
G01K  13/20 361 P	3	0	2F056	G01K  13/20	121	ŸŸ	Power sources, power control
G01K  13/20 361 R	3	0	2F056	G01K  13/20	30	ɽ	Indicating again
G01K  13/20 361 S	3	0	2F056	G01K  13/20	51	«˰¤θ	Detection of convergence, saturation
G01K  13/20 361 T	3	0	2F056	G01K  13/20	51	פȷ	Combined with clocks
G01K  13/20 361 W	3	0	2F056	G01K  13/20	24	ξѷ㡥	The types used to meet the both purposes, e.g. temperature
G01K  13/20 361 Z	3	0	2F056	G01K  13/20	98	¾Τ	Others
G01K  13/25  \	2	2	2F056	G01K  13/25	237	βפݸ֡㡥ɻߤΤΥ꡼֡Σ	Protective devices therefor, e.g. sleeves preventing contamination
G01K  15/00  \	0	0	2F056	G01K  15/00	732	ٷפλޤϳ	Testing or calibrating of thermometers
G01K  17/00  \	0	0	2F056	G01K  17/00	100	Ǯ̤¬	Measuring quantity of heat
G01K  17/00  A	0	0	2F056	G01K  17/00	254	Ǯ̷	Calorimeters
G01K  17/00  E	0	0	2F056	G01K  17/00	84	ήΤǮͥ륮	Thermal energy of fluids
G01K  17/00  S	0	0	2F056	G01K  17/00	44	Ǯ	Accumulated heat
G01K  17/00  Z	0	0	2F056	G01K  17/00	268	¾Τ	Others
G01K  17/02  \	1	1	2F056	G01K  17/02	6	ؼʪΰѤǮ̷ס㡥Ǯ̷	Calorimeters using transport of an indicating substance, e.g. evaporation calorimeters
G01K  17/04  \	1	1	2F056	G01K  17/04	8	ˡѤǮ̷	Calorimeters using compensation methods
G01K  17/06  \	1	1	2F056	G01K  17/06	82	ήưΤˤäƱФǮ̤¬ꡤ㡥ǮϤˤΡʣǣˣǣˣͥ	Measuring quantity of heat conveyed by flowing media, e.g. in heating systems (G01K 17/02, G01K 17/04 take precedence)
G01K  17/08  \	2	2	2F056	G01K  17/08	95	ٺ¬äȤ	based upon measurement of temperature difference
G01K  17/10  \	3	3	2F056	G01K  17/10	174	ήή֤βٺ¬Τή®¬ȤȤ߹碌	between an inlet and an outlet point, combined with measurement of rate of flow of the medium
G01K  17/12  \	4	4	2F056	G01K  17/12	12	ή̤ȲٺѤľܻؼ	Indicating product of flow and temperature difference directly
G01K  17/14  \	5	5	2F056	G01K  17/14	0	ξ¬˵ŪʤѤ	using mechanical means for both measurements
G01K  17/16  \	5	5	2F056	G01K  17/16	26	ξ¬ŵŪʤѤ	using electrical means for both measurements
G01K  17/18  \	5	5	2F056	G01K  17/18	0	¬ˤŵŪʤ¾¬ˤϵŪʤȤ	using electrical means for one measurement and mechanical means for the other
G01K  17/20  \	3	3	2F056	G01K  17/20	223	ռɽ̤ڤ벹ٺ¬ǮƳΨγǧȤȤ߹碌	across a radiating surface, combined with ascertainment of the heat-transmission coefficient
G01K  19/00  \	0	0	2F056	G01K  19/00	27	Ǯ̷פλޤϳ	Testing or calibrating calorimeters